Radial Force-Current Characteristic Analysis of Three-Pole Radial-Axial HMB

Author(s):  
Jintao Ju ◽  
Huangqiu Zhu ◽  
Chenyin Zhao
2014 ◽  
Vol 2014 ◽  
pp. 1-12 ◽  
Author(s):  
Yan Yang ◽  
Zeyuan Liu ◽  
Zhiquan Deng ◽  
Xin Cao

A Bearingless Switched Reluctance Motor (BSRM) has a complicated character of nonlinear coupling; therefore, it is a hard work to operate BSRM stably. In this paper, a new type of BSRMs with novel rotor structure is proposed by analyzing relationships between motor structure and theoretical formulae of levitation force and torque. The stator structure of this new motor is same as that of traditional BSRM and each stator pole can coil one winding or two windings, while the pole arc of rotor is wider. In order to analyze the characteristics of the proposed BSRM, finite-element (FE) models are used and a 12/4 one-set-winding BSRM and a 12/8 two-sets-windings BSRM are taken as examples. The analysis results indicate that the new scheme is effective for a stable levitation. It can realize decoupling control of torque and radial force, thus simplifying its control strategy and improving the use ratio of winding currents. A control system is designed for the 12/8 BSRM based on deducing its mathematical model. Compared with traditional BSRM, the proposed scheme is easier to be implemented.


2021 ◽  
Vol 1972 (1) ◽  
pp. 012013
Author(s):  
Xian Huizhu ◽  
Li Jiwei ◽  
Song Weiqiong ◽  
Zhao Cheng ◽  
Liu Heng ◽  
...  

2007 ◽  
Vol 177 (4S) ◽  
pp. 612-612
Author(s):  
Motoo Araki ◽  
Po N. Lam ◽  
Daniel J. Culkin ◽  
Pamela E. Fox ◽  
Glenn M. Sulley ◽  
...  

2008 ◽  
Vol 128 (12) ◽  
pp. 1373-1380
Author(s):  
Satoshi Sugahara ◽  
Kouhei Yamada ◽  
Haruhiko Nishio ◽  
Masaharu Edo ◽  
Toshiro Sato ◽  
...  

2012 ◽  
Vol 8 (1) ◽  
pp. 63
Author(s):  
Carlo Zivelonghi ◽  
Giulia Geremia ◽  
Michele Pighi ◽  
Flavio Ribichini ◽  
◽  
...  

Each component of a drug-eluting stent (DES) contributes to the safety of the device. Continuous efforts are being dedicated to the search of the optimal compromise between facility of use, safety and long-term efficacy. Shorter balloons reduce the vascular trauma beyond the stent struts; the metallic composition of the stent platform and the platform itself interact with the vascular wall in a long-lasting equilibrium between radial force, vessel patency and reparative cellular regrowth. The modality of drug elution is largely regulated by the chosen drug carrier, rather than by the chemical properties of the drug itself. Drug elution can be accomplished by permanent polymers that remain in the vessel wall forever, by biodegradable polymers that leave the naked metallic structure behind after their complete absorption, or even by direct release of the drug from stent reservoirs. The clinical performance of DESs has been exhaustively assessed in a large number of studies that have showed rapid and continuous improvements, from the first-generation DESs to the latest devices, based on substantial changes in stent design and polymer composition.


Sign in / Sign up

Export Citation Format

Share Document