scholarly journals Undetectable Concentrations of a Food and Drug Administration-approved High-sensitivity Cardiac Troponin T Assay to Rule Out Acute Myocardial Infarction at Emergency Department Arrival

2017 ◽  
Vol 24 (10) ◽  
pp. 1267-1277 ◽  
Author(s):  
Andrew D. McRae ◽  
Grant Innes ◽  
Michelle Graham ◽  
Eddy Lang ◽  
James E. Andruchow ◽  
...  
2015 ◽  
Vol 187 (8) ◽  
pp. E243-E252 ◽  
Author(s):  
Tobias Reichlin ◽  
Raphael Twerenbold ◽  
Karin Wildi ◽  
Maria Rubini Gimenez ◽  
Nathalie Bergsma ◽  
...  

2019 ◽  
Vol 9 (1) ◽  
pp. 14-22 ◽  
Author(s):  
M Arslan ◽  
A Dedic ◽  
E Boersma ◽  
EA Dubois

Aims: The purpose of this study was to determine (a) the ability of serial high-sensitivity cardiac troponin T measurements to rule out acute myocardial infarction and (b) the ability of a single high baseline high-sensitivity cardiac troponin T measurement to rule in acute myocardial infarction in patients presenting to the emergency department with acute chest pain. Methods and results: Embase, Medline, Cochrane, Web of Science and Google scholar were searched for prospective cohort studies that evaluated parameters of diagnostic accuracy of serial high-sensitivity cardiac troponin T to rule out acute myocardial infarction and a single baseline high-sensitivity cardiac troponin T value>50 ng/l to rule in acute myocardial infarction. The search yielded 21 studies for the systematic review, of which 14 were included in the meta-analysis, with a total of 11,929 patients and an overall prevalence of acute myocardial infarction of 13.0%. For rule-out, six studies presented the sensitivity of serial measurements <14 ng/l. This cut-off classified 60.1% of patients as rule-out and the summary sensitivity was 96.7% (95% confidence interval: 92.3–99.3). Three studies presented the sensitivity of a one-hour algorithm with a baseline high-sensitivity cardiac troponin T value<12 ng/l and delta 1 hour <3 ng/l. This algorithm classified 60.2% of patients as rule-out and the summary sensitivity was 98.9% (96.4–100). For rule-in, six studies reported the specificity of baseline high-sensitivity cardiac troponin T value>50 ng/l. The summary specificity was 94.6% (91.5–97.1). Conclusion: Serial high-sensitivity cardiac troponin T measurement strategies to rule out acute myocardial infarction perform well, and a single baseline high-sensitivity cardiac troponin T value>50 ng/l to rule in acute myocardial infarction has a high specificity.


2013 ◽  
Vol 34 (suppl 1) ◽  
pp. P424-P424
Author(s):  
R. Twerenbold ◽  
T. Reichlin ◽  
M. Rubini-Gimenez ◽  
M. Mueller ◽  
K. Wildi ◽  
...  

Open Heart ◽  
2021 ◽  
Vol 8 (1) ◽  
pp. e001682
Author(s):  
Andreas Roos ◽  
Martin J Holzmann

ObjectiveSeveral high-sensitivity cardiac troponin (hs-cTn)-based strategies exist for rule-out of myocardial infarction (MI). It is unknown whether historical hs-cTnT concentrations can be used. This study aim to evaluate the performance of a rule-out strategy based on the European Society of Cardiology (ESC) 0/1-hour algorithm, using historical hs-cTnT concentrations.MethodsAll visits among patients with chest pain in the emergency department at nine different hospitals in Sweden from 2012 to 2016 were eligible (221 490 visits). We enrolled patients with a 0-hour hs-cTnT of <12 ng/L, a second hs-cTnT measured within 3.5 hours, and ≥1 historical hs-cTnT available. We calculated the risks of MI and all-cause mortality using two rule-out strategies: (1) a delta hs-cTnT of <3 ng/L between the 0-hour hs-cTnT and the second hs-cTnT (modified ESC algorithm) and (2) a historical hs-cTnT <12 ng/L and a delta hs-cTnT of <3 ng/L in relation to the 0-hour hs-cTnT (historical-hs-cTnT algorithm).ResultsA total of 8432 patients were included, of whom 84 (1.0%) had an MI. The modified ESC algorithm triaged 8100 (96%) patients toward ruled-out, for whom 30-day MI risk and negative predictive value (NPV) for MI (95% CI) were 0.4% (0.3% to 0.6%) and 99.6% (99.4% to 99.7%), respectively. The historical-hs-cTnT algorithm ruled out 6700 (80%) patients, with a 30-day MI risk of 0.5% (0.4% to 0.8%) and NPV of 99.5% (99.2% to 99.6%).ConclusionsThe application of algorithm resulted in similar MI risk and NPV to an established algorithm. The usefulness of historical hs-cTnT concentrations should merit further attention.


2017 ◽  
Vol 166 (10) ◽  
pp. 715 ◽  
Author(s):  
John W. Pickering ◽  
Martin P. Than ◽  
Louise Cullen ◽  
Sally Aldous ◽  
Ewoud ter Avest ◽  
...  