scholarly journals Retinal vessel oxygen saturation and vessel diameter in retinitis pigmentosa

2014 ◽  
Vol 92 (5) ◽  
pp. 449-453 ◽  
Author(s):  
Thor Eysteinsson ◽  
Sveinn H. Hardarson ◽  
David Bragason ◽  
Einar Stefánsson
2015 ◽  
Vol 254 (2) ◽  
pp. 243-252 ◽  
Author(s):  
Yao Zong ◽  
Leilei Lin ◽  
Changxian Yi ◽  
Xia Huang ◽  
Yue Fu ◽  
...  

2015 ◽  
Vol 35 (5) ◽  
pp. 562-569 ◽  
Author(s):  
Qishan Zheng ◽  
Yao Zong ◽  
Li Li ◽  
Xia Huang ◽  
Leilei Lin ◽  
...  

Eye ◽  
2018 ◽  
Vol 32 (7) ◽  
pp. 1209-1219 ◽  
Author(s):  
Rossiana I. Bojinova ◽  
Daniel F. Schorderet ◽  
Christophe Valmaggia ◽  
Cengiz Türksever ◽  
Andreas Schoetzau ◽  
...  

2013 ◽  
Vol 91 ◽  
pp. 0-0 ◽  
Author(s):  
C TüRKSEVER ◽  
C VALMAGGIA ◽  
S ORGUEL ◽  
DF SCHORDERT ◽  
MG TODOROVA

2017 ◽  
Vol 33 (6) ◽  
pp. 459-465 ◽  
Author(s):  
Xiaonan Yang ◽  
Danping Huang ◽  
Siming Ai ◽  
Xuanwei Liang ◽  
Jing Zhao ◽  
...  

PLoS ONE ◽  
2021 ◽  
Vol 16 (12) ◽  
pp. e0260120
Author(s):  
Robert Arnar Karlsson ◽  
Olof Birna Olafsdottir ◽  
Vedis Helgadottir ◽  
Soumaya Belhadj ◽  
Thorunn Scheving Eliasdottir ◽  
...  

Purpose Retinal oximetry is a technique based on spectrophotometry where images are analyzed with software capable of calculating vessel oxygen saturation and vessel diameter. In this study, the effect of automation of measurements of retinal vessel oxygen saturation and vessel diameter is explored. Methods Until now, operators have had to choose each vessel segment to be measured explicitly. A new, automatic version of the software automatically selects the vessels once the operator defines a measurement area. Five operators analyzed image pairs from the right eye of 23 healthy subjects with semiautomated retinal oximetry analysis software, Oxymap Analyzer (v2.5.1), and an automated version (v3.0). Inter- and intra-operator variability was investigated using the intraclass correlation coefficient (ICC) between oxygen saturation measurements of vessel segments in the same area of the retina. Results For semiautomated saturation measurements, the inter-rater ICC was 0.80 for arterioles and venules. For automated saturation measurements, the inter-rater ICC was 0.97 for arterioles and 0.96 for venules. For semiautomated diameter measurements, the inter-rater ICC was 0.71 for arterioles and venules. For automated diameter measurements the inter-rater ICC was 0.97 for arterioles and 0.95 for venules. The inter-rater ICCs were different (p < 0.01) between the semiautomated and automated version in all instances. Conclusion Automated measurements of retinal oximetry values are more repeatable compared to measurements where vessels are selected manually.


2010 ◽  
Vol 88 ◽  
pp. 0-0
Author(s):  
SH HARDARSON ◽  
HR BERGVINSSON ◽  
E STEFANSSON

2015 ◽  
Vol 93 (7) ◽  
pp. e527-e533 ◽  
Author(s):  
Lisette T. Lopez Torres ◽  
Cengiz Türksever ◽  
Andreas Schötzau ◽  
Selim Orgül ◽  
Margarita G. Todorova

2018 ◽  
Vol 97 (3) ◽  
pp. 279-286 ◽  
Author(s):  
Yiquan Yang ◽  
Diya Yang ◽  
Yunxiao Sun ◽  
Yuan Xie ◽  
Zheng Zhang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document