high myopia
Recently Published Documents


TOTAL DOCUMENTS

1725
(FIVE YEARS 560)

H-INDEX

61
(FIVE YEARS 6)

2022 ◽  
Vol 8 ◽  
Author(s):  
Fang Liu ◽  
Jing Zhao ◽  
Tian Han ◽  
Yang Shen ◽  
Meng Li ◽  
...  

Purpose:To explore the feasibility and repeatability of a novel glasses-free display combined with random-dot stimulus and eye-tracking technology for screening stereopsis in adults.Methods:A total of 74 patients aged 18–44 years were recruited in this study (male: female, 32:42), including 33 patients with high myopia [≤ -6.0 diopters (D)] and 41 patients with moderate-to-low myopia (>-6.0 D). Stereopsis was measured using glasses-free, polarized, and Titmus stereotests. All patients completed a visual fatigue questionnaire after the polarized stereotest and glasses-free test. Kendall's W and Cohen's Kappa tests were used to evaluate repeatability and consistency of the glasses-free stereotest.Results:The stereotest results using the glasses-free monitor showed strong repeatability in the three consecutive tests (W = 0.968, P < 0.01) and good consistency with the polarized stereotest and Titmus test results (vs. polarization: Kappa = 0.910, P < 0.001; vs. Titmus: Kappa = 0.493, P < 0.001). Stereopsis levels of the high myopia group were significantly poorer than those of the moderate-to-low myopia group in three stereotest monitors (all P < 0.05). There was no significant difference in visual fatigue level between the polarized and the glasses-free display test (P = 0.72). Compared with the polarized test, 56.76% of patients preferred the glasses-free display and found it more comfortable, 20.27% reported both tests to be acceptable.Conclusions:In our adult patients, the new eye-tracking glasses-free display system feasibly screened stereopsis with good repeatability, consistency, and patient acceptance.


2022 ◽  
Author(s):  
Henry Chen ◽  
Xiao Chun Ling ◽  
Da-Wen Lu ◽  
Lan-Hsing Chuang ◽  
Wei-Wen Su ◽  
...  

Abstract The risks of misdiagnosing a healthy individual as glaucomatous or vice versa may be high in a population with a large majority of highly myopic individuals, due to considerable morphologic variability in high myopic fundus. This study aims to compare the diagnostic ability of the regular and long axial length databases in the RS-3000 Advance SD-OCT (Nidek) device to correctly diagnose glaucoma with high myopia. Patients with high myopia (axial length ≥ 26.0 mm) in Chang Gung Memorial Hospital, Taiwan between 2015 and 2020 were included. Glaucoma was diagnosed based on glaucomatous discs, visual field defects and corresponding retinal nerve fiber layer defects. The sensitivity, specificity, diagnostic accuracy and likelihood ratios of diagnosing glaucoma via mGCC thickness in both superior/inferior and GChart mapping using the regular and long axial length normative databases. The specificity and diagnostic accuracy of mGCC thickness for distinguishing glaucomatous eyes from nonglaucomatous eyes among highly myopic eyes were significantly improved using the long axial length database (p=0.046). There were also significant proportion changes in S/I mapping as well as GChart mapping (37.3% and 48.0%, respectively; p<0.01) from abnormal to normal in the myopic normal eye group when using the long axial length normative database. The study revealed that clinicians could utilize a long axial length database to effectively decrease the number of false-positive diagnoses or to correctly identify highly myopic normal eyes misdiagnosed as glaucomatous eyes.


2022 ◽  
pp. bjophthalmol-2021-319769
Author(s):  
Yupeng Xu ◽  
Junjie Deng ◽  
Bo Zhang ◽  
Xian Xu ◽  
Tianyu Cheng ◽  
...  

BackgroundVision-dependent mechanisms play a role in myopia progression in childhood. Thus, we investigated the distribution of ocular and corneal higher-order aberrations (HOAs) in highly myopic Chinese children and adolescents and the relationship between HOA components and 1-year axial eye growth.MethodsBaseline cycloplegic ocular and corneal HOAs, axial length (AL), spherical equivalent (SE), astigmatism and interpupillary distance (IPD) were determined for the right eyes of 458 highly myopic (SE ≤−5.0D) subjects. HOAs were compared among baseline age groups (≤12 years, 13–15 years and 16–18 years). Ninety-nine subjects completed the 1-year follow-up. Linear mixed model analyses were applied to determine the association between HOA components, other known confounding variables (age, gender, SE, astigmatism and IPD) and axial growth. A comparison with data from an early study of moderate myopia were conducted.ResultsAlmost all ocular HOAs and few corneal HOAs exhibited significant differences between different age groups (all p<0.05). After 1 year, only ocular HOA components was significantly negative associated with a longer AL, including secondary horizontal comatic aberration (p=0.019), primary spherical aberration (p<0.001) and spherical HOA (p=0.026). Comparing with the moderate myopia data, the association of comatic aberration with AL growth was only found in high myopia.ConclusionIn highly myopic children and adolescents, lower levels of annual ocular secondary horizontal comatic aberration changes, besides spherical aberrations, were associated with axial elongation. This suggests that ocular HOA plays a potential role in refractive development in high myopia.


2022 ◽  
Vol 12 ◽  
Author(s):  
Fuxin Zhao ◽  
Wei Chen ◽  
Hui Zhou ◽  
Peter S. Reinach ◽  
Yuhan Wang ◽  
...  

Myopia is the most common cause of refractive error worldwide. High myopia is a severe type of myopia, which usually accompanies pathological changes in the fundus. To identify high myopia susceptibility genes, DNA-pooling based genome-wide association analysis was used to search for a correlation between single nucleotide polymorphisms and high myopia in a Han Chinese cohort (cases vs. controls in discovery stage: 507 vs. 294; replication stage 1: 991 vs. 1,025; replication stage 2: 1,021 vs. 52,708). Three variants (rs10889602T/G, rs2193015T/C, rs9676191A/C) were identified as being significantly associated with high myopia in the discovery, and replication stage. rs10889602T/G is located at the third intron of phosphodiesterase 4B (PDE4B), whose functional assays were performed by comparing the effects of rs10889602T/T deletion of this risk allele on PDE4B and COL1A1 gene and protein expression levels in the rs10889602T/Tdel/del, rs10889602T/Tdel/wt, and normal control A549 cell lines. The declines in the PDE4B and COL1A1 gene expression levels were larger in the rs10889602T/T deleted A549 cells than in the normal control A549 cells (one-way ANOVA, p &lt; 0.001). The knockdown of PDE4B by siRNA in human scleral fibroblasts led to downregulation of COL1A1. This correspondence between the declines in rs10889602 of the PDE4B gene, PDE4B knockdown, and COL1A1 protein expression levels suggest that PDE4B may be a novel high myopia susceptibility gene, which regulates myopia progression through controlling scleral collagen I expression levels. More studies are needed to determine if there is a correlation between PDE4B and high myopia in other larger sample sized cohorts.


Eye ◽  
2022 ◽  
Author(s):  
Riccardo Sacconi ◽  
Enrico Borrelli ◽  
Siva Balasubramanian ◽  
Giovanna Vella ◽  
Marco Battista ◽  
...  

2022 ◽  
Author(s):  
Lixia Sun ◽  
Hui-Ni Lin ◽  
Vishal Jhanji ◽  
Tsz Kin Ng ◽  
Rui-feng Ji ◽  
...  

Abstract Purpose: To evaluate the four measurement approaches on the determination of effective optical zone (EOZ) using Scheimpflug tomography after SMILE surgery in eyes with high myopia.Setting: Corneal refractive surgery conducted in eye hospital in southern ChinaDesign: A retrospective cohort study.Methods: Total 74 subjects were recruited. EOZ was measured at 3 months postoperatively using Vertex-Based total corneal refraction method (EOZV), pupil-based total corneal refraction method (EOZP), 4 mm-Ring-Based total corneal refraction method (EOZ4), and axial curvature difference map (EOZD), and their consistencies were compared. EOZs and planned optical zone (POZ) were compared and analyzed with eccentricity, ablation degree (AD) and total corneal aberrations.Results: Mean AD was -6.87 ± 0.75 D, and eccentricity was 0.30 ± 0.17 mm. At 3 months after surgery, the mean root mean square of ΔHOA, ΔComa, ΔTrefoil and ΔSA were 0.53 ± 0.27 μm, 0.36 ± 0.20 μm, 0.01 ± 0.84 μm, and, 0.16 ± 0.14 μm respectively. EOZV, EOZP, EOZ4 and EOZD were 5.87 ± 0.44 mm, 5.85 ± 0.45 mm, 4.78 ± 0.40 mm, 5.29 ± 0.27 mm respectively, which were significantly smaller than POZ 6.48 ± 0.16 mm. Bland Altman plots showed a good consistency between the four EOZs. The difference between the EOZV and EOZP was 0.02 mm within the range of clinically acceptable difference. In addition, EOZD was positively correlated with AD, and the eccentricity was positively correlated with ΔHOA, ΔComa and ΔSA.Conclusions: All 4 measurement approaches demonstrated the reduction of EOZs compared to POZ. EOZV was the closest to POZ, followed by EOZP. ΔEOZs showed no significant difference with eccentricity, AD and corneal aberrations. Our results are useful for the full characterization of corneal treatment profiles after kerato-refractive surgery.


2022 ◽  
Author(s):  
Ralph Mazijk ◽  
Annechien E.G. Haarman ◽  
Lies H. Hoefsloot ◽  
Jan Roelof Polling ◽  
Marianne Tienhoven ◽  
...  

2022 ◽  
Vol 63 (1) ◽  
pp. 8
Author(s):  
Shi-Ming Li ◽  
Shifei Wei ◽  
David A. Atchison ◽  
Meng-Tian Kang ◽  
Luoru Liu ◽  
...  
Keyword(s):  

Cureus ◽  
2022 ◽  
Author(s):  
Sanjay Kumar Sahu ◽  
Jyoti Ranjan Behera ◽  
Jishnu KR ◽  
Moparthi Puramjai ◽  
Ramakrushna Gudu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document