automation of measurements
Recently Published Documents


TOTAL DOCUMENTS

23
(FIVE YEARS 6)

H-INDEX

1
(FIVE YEARS 0)

PLoS ONE ◽  
2021 ◽  
Vol 16 (12) ◽  
pp. e0260120
Author(s):  
Robert Arnar Karlsson ◽  
Olof Birna Olafsdottir ◽  
Vedis Helgadottir ◽  
Soumaya Belhadj ◽  
Thorunn Scheving Eliasdottir ◽  
...  

Purpose Retinal oximetry is a technique based on spectrophotometry where images are analyzed with software capable of calculating vessel oxygen saturation and vessel diameter. In this study, the effect of automation of measurements of retinal vessel oxygen saturation and vessel diameter is explored. Methods Until now, operators have had to choose each vessel segment to be measured explicitly. A new, automatic version of the software automatically selects the vessels once the operator defines a measurement area. Five operators analyzed image pairs from the right eye of 23 healthy subjects with semiautomated retinal oximetry analysis software, Oxymap Analyzer (v2.5.1), and an automated version (v3.0). Inter- and intra-operator variability was investigated using the intraclass correlation coefficient (ICC) between oxygen saturation measurements of vessel segments in the same area of the retina. Results For semiautomated saturation measurements, the inter-rater ICC was 0.80 for arterioles and venules. For automated saturation measurements, the inter-rater ICC was 0.97 for arterioles and 0.96 for venules. For semiautomated diameter measurements, the inter-rater ICC was 0.71 for arterioles and venules. For automated diameter measurements the inter-rater ICC was 0.97 for arterioles and 0.95 for venules. The inter-rater ICCs were different (p < 0.01) between the semiautomated and automated version in all instances. Conclusion Automated measurements of retinal oximetry values are more repeatable compared to measurements where vessels are selected manually.


2021 ◽  
Author(s):  
Robert Arnar Karlsson ◽  
Olof Birna Olafsdottir ◽  
Soumaya Belhadj ◽  
Vedis Helgadottir ◽  
Thorunn Scheving Eliasdottir ◽  
...  

AbstractPurposeRetinal oximetry is a technique based on spectrophotometry where images are analyzed with software capable of calculating vessel oxygen saturation and vessel diameter. In this study, the effect of automation of measurements of retinal vessel oxygen saturation and vessel diameter is explored.MethodsUntil now, operators have had to choose each vessel segment to be measured explicitly. A new, automatic version of the software automatically selects the vessels once the operator defines a measurement area.Five operators analyzed image pairs from the right eye of 23 healthy subjects with semiautomated retinal oximetry analysis software, Oxymap Analyzer (v2.5.1), and an automated version (v3.0). Inter- and intra-operator variability was investigated using the intraclass correlation coefficient (ICC) between oxygen saturation measurements of vessel segments in the same area of the retina.ResultsFor manual saturation measurements, the inter-rater ICC was 0.80 for arterioles and venules. For automated saturation measurements, the inter-rater ICC was 0.97 for arterioles and 0.96 for venules. For manual diameter measurements, the inter-rater ICC was 0.71 for arterioles and venules. For automated diameter measurements the inter-rater ICC was 0.97 for arterioles and 0.95 for venules. The inter-rater ICCs were different (p < 0.01) between the semiautomated and automated version in all instances.ConclusionAutomated measurements of retinal oximetry values are more repeatable compared to measurements where vessels are selected manually.


Author(s):  
Pablo MEDINA-BRISEÑO ◽  
Jesus Ezequiel MOLINAR-SOLIS ◽  
Juan Jose CHAVEZ-VELARDE ◽  
Humberto BRACAMONTES-DEL TORO

This article provides a quick introduction to the automation of measurements using a public domain language such as Python. We bring references for the used libraries and the basic commands for manipulating the GPIB port. Some examples are provided.


2019 ◽  
Vol 30 ◽  
pp. 11006
Author(s):  
Andrey Zhukov ◽  
Vasily Atamasov ◽  
Grigory Malenko

The article discusses an example of the automation of the process of measuring the dielectric constant of materials by the capacitor method using the LabVIEW graphical programming environment and the Agilent E4980A precision LCR meter. A description of the hardwaresoftware complex is presented, as well as the measurement results.


2018 ◽  
Vol 19 (4) ◽  
pp. 363-367
Author(s):  
B.S. Dzundza ◽  
V.V. Prokopiv ◽  
T.M. Mazur ◽  
L.D. Yurchyshyn

A method of measuring electrical conductivity and photoconductivity of semiconductor films with high electrical resistance has been described. The electric circuit has been presented and the computer program has been developed. That provides automation of measurements, registration and primary processing of data with possibility of plotting time dependences for preliminary analysis of experimental data during measurement.


Author(s):  
Rasul I. Kuliev ◽  
Sergey A. Sheptunov ◽  
Astemir O. Shevhuzhev

Author(s):  
V. A. Knyaz ◽  
A. V. Gaboutchian

Tooth measurements (odontometry) are performed for various scientific and practical applications, including dentistry. Present-day techniques are being increasingly based on 3D model use that provides wider prospects in comparison to measurements on real objects: teeth or their plaster copies. The main advantages emerge through application of new measurement methods which provide the needed degree of non-invasiveness, precision, convenience and details. Tooth measurements have been always regarded as a time-consuming research, even more so with use of new methods due to their wider opportunities. This is where automation becomes essential for further development and implication of measurement techniques. In our research automation in obtaining 3D models and automation of measurements provided essential data that was analysed to suggest recommendations for tooth preparation – one of the most responsible clinical procedures in prosthetic dentistry – within a comparatively short period of time. The original photogrammetric 3D reconstruction system allows to generate 3D models of dental arches, reproduce their closure, or occlusion, and to perform a set of standard measurement in automated mode.


Sign in / Sign up

Export Citation Format

Share Document