scholarly journals Predictability of ab‐interno trabeculectomy success in the subsequent eye: A contralateral eye comparison study

2021 ◽  
Vol 49 (3) ◽  
pp. 242-250
Author(s):  
David Kiessling ◽  
Corinna Rennings ◽  
Matthias Hild ◽  
Alexandra Lappas ◽  
Thomas S. Dietlein ◽  
...  
Author(s):  
D. Kiessling ◽  
C. Rennings ◽  
M. Hild ◽  
A. Lappas ◽  
T. S. Dietlein ◽  
...  

Abstract Purpose To determine the impact of failed ab-interno trabeculectomy on the postoperative outcome of subsequent XEN45 gel stent (Allergan, CA, USA) implantation in pseudophakic eyes. Methods In this retrospective single-center study, we included 60 pseudophakic eyes from 60 participants who underwent XEN45 gel stent implantation. Thirty eyes each underwent primary stent implantation (control group) or had previously undergone a failed ab-interno trabeculectomy (trabectome group). The groups were matched at a 1:1 ratio based on the following criteria: preoperative and maximum Intraocular pressure (IOP), preoperative medication score, cup/disk-ratio, follow-up time, best-corrected visual acuity at baseline, age, and the proportion of patients classified as primary open angle glaucoma or exfoliation glaucoma. We defined a successful surgery by the following three scores: an IOP reduction > 20% and IOP at the longest follow-up < 21 mmHg (Score A) or < 18 mmHg (Score B) or IOP ≤ 15 mmHg and an IOP reduction ≥ 40% (Score C). One open conjunctival revision was allowed in all scores, and a repeat surgery was considered a failure. Results Following an average follow-up period of 22 ± 12 months, we observed a mean IOP reduction of 38%, from 23.5 ± 5.2–14.5 ± 5.0 mmHg. Comparative analyses between the groups did not reveal a significant difference in the postoperative IOP, postoperative medication score, side effects, revision rate, repeat surgery rate, or success rate. Conclusions Trabectome is a viable first-line procedure for medically uncontrolled glaucoma before filtering ab-interno microstent surgery is considered.


2016 ◽  
Vol 25 (9) ◽  
pp. 758-762 ◽  
Author(s):  
Thomas Wecker ◽  
Matthias Neuburger ◽  
Laura Bryniok ◽  
Kathrin Bruder ◽  
Jan Luebke ◽  
...  

2020 ◽  
Vol 258 (12) ◽  
pp. 2775-2780 ◽  
Author(s):  
Yousef Al Yousef ◽  
Alicja Strzalkowska ◽  
Jost Hillenkamp ◽  
André Rosentreter ◽  
Nils A. Loewen

Abstract Purpose To achieve a highly balanced comparison of trabecular bypass stenting (IS2, iStent inject) with ab interno trabeculectomy (T, Trabectome) by exact matching. Methods Fifty-three IS2 eyes were matched to 3446 T eyes. Patients were matched using exact matching by baseline intraocular pressure (IOP), the number of glaucoma medications, and glaucoma type, and using nearest neighbor matching by age. Individuals without a close match were excluded. All surgeries were combined with phacoemulsification. Results A total of 78 eyes (39 in each group) could be matched as exact pairs with a baseline IOP of 18.3 ± 5.1 mmHg and glaucoma medications of 2.7 ± 1.2 in each. IOP in IS2 was reduced to 14.6 ± 4.2 mmHg at 3 months and in T to a minimum of 13.1 ± 3.2 mmHg at 1 month. In IS2, IOP began to rise again at 6 months, eventually exceeding baseline. At 24 months, IOP in IS2 was 18.8 ± 9.0 mmHg and in T 14.2 ± 3.5 mmHg. IS2 had a higher average IOP than T at all postoperative visits (p < 0.05 at 1, 12, 18 months). Glaucoma medications decreased to 2.0 ± 1.5 in IS2 and to 1.5 ± 1.4 in T. Conclusion T resulted in a larger and sustained IOP reduction compared with IS2 where a rebound occurred after 6 months to slightly above preoperative values.


Sign in / Sign up

Export Citation Format

Share Document