Linear and volumetric wear of conventional and milled denture teeth

Author(s):  
Susun Theresa Kim ◽  
Donald Ryan Cook ◽  
Jean‐Pierre Albouy ◽  
Ingeborg De Kok ◽  
Taiseer A. Sulaiman
2000 ◽  
Vol 27 (3) ◽  
pp. 217-226 ◽  
Author(s):  
A. Keshvad ◽  
R. B. Winstanley ◽  
T. Hooshmand

Author(s):  
J L Cunningham ◽  
I Bisbinas ◽  
R Greenwood ◽  
I D Learmonth

The shadowgraph technique is a relatively easy-to-use and inexpensive method of wear measurement from explanted acetabular cups. In this technique, from a mould of the internal surface of the cup, measurements of linear wear and wear angle can be obtained, from which volumetric wear can be calculated. In this study the measurement precision of this technique was assessed and the influence of different observers and multiple moulds was also determined. It was found that linear wear (coefficient of variation (CV) = 1.49 per cent) can be more precisely determined than wear angle (CV = 8.18 per cent) and that both the observer and the mould can significantly influence the results obtained, although the influence of the mould is considerably less than that of the observer.


Wear ◽  
1981 ◽  
Vol 67 (2) ◽  
pp. 177-185 ◽  
Author(s):  
C.N. Raptis ◽  
J.M. Powers ◽  
P.L. Fan

2017 ◽  
Vol 17 (04) ◽  
pp. 1750074
Author(s):  
MD ABU HASAN ◽  
PANOS S. SHIAKOLAS

This study compares the biomechanical behavior of a mandibular full-arch fixed implant prosthesis with four implants under lingualized and conventional balanced occlusion schemes. The acrylic resin denture was supported by four titanium cylindrical implants and connected via a titanium prosthetic rectangular bar. Orthotropic material was used for the cortical and cancellous bones. The applied loadings were vertical and bilateral: 100[Formula: see text]N on first molar and 50[Formula: see text]N on first and second premolars each. For the lingualized balanced occlusion, the loadings were applied in central fossae of the posterior teeth, whereas for the conventional balanced occlusion the loadings were applied in central fossae and buccal cusps. The maximum von-Mises stresses for the lingualized and conventional balanced schemes were 301[Formula: see text]MPa and 25[Formula: see text]MPa, respectively, and were located at the neck of the posterior implants. In the denture teeth, the highest stress was located at the beginning of the cantilever extension. In the cortical bone, according to Tsai–Wu criterion, the failure index for the lingualized balanced occlusion was 1.10 and for the conventional balanced occlusion was 0.83. Thus, the conventional balanced occlusion demonstrated more favorable stress distribution in the implants and the cortical bone than the lingualized balanced occlusion.


Sign in / Sign up

Export Citation Format

Share Document