Characterization of the Performance of a Custom Program for Image Processing of Pressure Sensitive Film

2008 ◽  
Vol 131 (1) ◽  
Author(s):  
Muturi G. Muriuki ◽  
Lars G. Gilbertson ◽  
Christopher D. Harner

A custom program for the processing of pressure sensitive (Fuji) film data is presented and validated in this paper. Some of the shortcomings of previous descriptions of similar programs in literature are addressed. These shortcomings include incomplete descriptions of scan resolution, processing technique, and accuracy of results. Of these, the accuracy of results is the most important and is addressed in this study by using Fuji film calibration data. In Fuji film calibration, known loads are applied to forms with known area. The accuracy of this program and that of the two commercially available image processing programs were determined. The results of the custom program are found to be within 10% of the results from the commercial programs and from experimental data. This level of accuracy is the same reported level of accuracy of Fuji film, verifying the custom program for use in Fuji film contact pressure and area measurements.

2020 ◽  
Vol 16 (3) ◽  
pp. 189-193
Author(s):  
David H. Wei ◽  
Peter Tang

The study of contact biomechanics of the wrist is a challenge. This is partly due to the relatively small size of the joint as well as the lack of space in the radiocarpal joint which makes the delivery of investigative materials such as pressure sensitive film without causing artifact, difficult. Fortunately, a number of authors have studied the intact wrist, the scapholunate ligament injured wrist, the proximal row carpectomy and the scaphoid excision, four bone fusion. Despite some contrasting findings, there are some general concepts that we understand about wrist mechanics.


Foot & Ankle ◽  
1992 ◽  
Vol 13 (4) ◽  
pp. 220-223 ◽  
Author(s):  
Alan S. Tuckman ◽  
Frederick W. Werner ◽  
Maria D. Fortino ◽  
Joseph A. Spadaro

Although a number of pathologies of the forefoot in ballet dancers on pointe have been described, pressures and deforming forces have not been adequately measured. To evaluate the possible use of pressure-sensitive film (PSF) in measuring the pressures on the external soft tissues in such a confined space as the dancer's toe shoe, it was tested and calibrated with 20 cadaver toes. Each cadaver toe was internally stabilized and loaded longitudinally against PSF on a flat surface. The resultant films were analyzed with a video imaging system and the pressures and total forces were determined. Results showed that the linearity of the PSF to pressure had a regression value of 0.98. By using two sensitivity ranges of films, the total force measured by the PSF was found to be within 10% of the known applied force on each toe. The PSF, therefore, may very well be a useful and accurate method of measuring external soft tissue pressures on the forefoot.


2009 ◽  
Vol 35 (1) ◽  
pp. 43-45 ◽  
Author(s):  
Y.-L. Zhu ◽  
Y.-Q. Xu ◽  
J. Ding ◽  
J. Li ◽  
B. Chen ◽  
...  

We investigated the biomechanics of the radiocapitate joint after a proximal row carpectomy in six fresh-frozen cadaver wrists using super-low-pressure-sensitive film on a material testing system. The average pressure within the lunate fossa increased significantly from 23.2 to 136.4 N/cm2 with a sharp decrease in the contact area from 2.08 to 0.30 cm2 after a proximal row carpectomy. The cartilage of the proximal capitate had four sub-facets and therefore was not as smooth as the normal proximal lunate. We found that the wrist was overloaded after a proximal row carpectomy and the main cause was the anatomical mismatch of the radiocapitate articulation.


2020 ◽  
Vol 142 (5) ◽  
Author(s):  
Adam R. Brink ◽  
Robert J. Kuether ◽  
Matthew D. Fronk ◽  
Bryan L. Witt ◽  
Brendan L. Nation

Abstract The member stiffness and pressure distribution in a bolted joint is significantly influenced by the contact area of the mechanical interface under a prescribed preload force. This research explores the influence of as-built surface profiles for nominally flat interfaces of a C-Beam assembly with two well-defined contact regions. A high-fidelity finite element model is created such that the model uncertainty is minimized by updating and calibrating the piece parts prior to the preload assembly procedure. The model is then assembled and preloaded to evaluate the contact stresses and contact area for both nominally flat and perturbed non-flat surfaces based on three-dimensional surface topography measurements. The predicted pressures are validated with digitized pressure-sensitive film measurements. The high-fidelity modeling reveals how the compliance and thickness of the pressure-sensitive film alter the measured pressures, leading to incorrect evaluations of the stresses and contact area in the joint. The resulting low-level dynamic behavior of the preloaded assembly is shown to be sensitive to the true contact area by linearizing the nonlinear finite element model about the preloaded equilibrium and performing a computational modal analysis. The resonant frequencies are validated with experimental measurements to demonstrate the effect of the contact area on the modal characteristics of the bolted assembly. Vibration modes and loading patterns exhibit varying levels of sensitivity to the contact area in the joint, leading to an improved physical understanding of the influence of contact mechanics on the low-level linear vibration modes of jointed assemblies.


2005 ◽  
Vol 25 (1) ◽  
pp. 57-66 ◽  
Author(s):  
Glenn Čada ◽  
John Smith ◽  
Jessica Busey