Subcooled Boiling Heat Transfer for Turbulent Flow of Water in a Short Vertical Tube

2009 ◽  
Vol 132 (1) ◽  
Author(s):  
Koichi Hata ◽  
Suguru Masuzaki

The subcooled boiling heat transfer and the critical heat flux (CHF) due to exponentially increasing heat inputs with various periods (Q=Q0 exp(t/τ), τ=22.52 ms–26.31 s) were systematically measured by an experimental water loop flow and observed by an infrared thermal imaging camera. Measurements were made on a 3 mm inner diameter, a 66.5 mm heated length, and a 0.5 mm thickness of platinum test tube, which was divided into three sections (upper, mid, and lower positions). The axial variations of the inner surface temperature, the heat flux, and the heat transfer coefficient from nonboiling to critical heat flux were clarified. The results were compared with other correlations for the subcooled boiling heat transfer and authors’ transient CHF correlations. The influence of exponential period (τ) and flow velocity on the subcooled boiling heat transfer and the CHF was investigated and the predictable correlation of the subcooled boiling heat transfer for turbulent flow of water in a short vertical tube was derived based on the experimental data. In this work, the correlation gave 15% difference for subcooled boiling heat transfer coefficients. Most of the CHF data (101 points) were within 15% and −30 to +20% differences of the authors’ transient CHF correlations against inlet and outlet subcoolings, respectively.

Author(s):  
Koichi Hata ◽  
Nobuaki Noda

The subcooled boiling heat transfer for Platinum test tube divided into three sections (upper, mid and lower positions) for the flow velocities (u = 4.0 to 13.3 m/s), the inlet liquid temperatures (Tin = 295.26 to 305.25 K), the inlet pressures (Pin = 739.26 to 1064.48 kPa) and the exponentially increasing heat input with various periods (Q = Q0 exp(t/τ), τ = 22.52 ms to 26.31 s) was systematically measured by an experimental water loop comprised of a pressurizer. The Platinum test tube of inner diameter (d = 3 mm), heated length (L = 66.5 mm), L/d (= 22.17) and wall thickness (δ = 0.5 mm) with a commercial finish of inner surface (average roughness, Ra = 0.40 μm) is used in this work. The outer surface temperature of the test tube was observed by an infrared thermal imaging camera. The axial variations of the inner surface temperature, the heat flux and the heat transfer coefficient from non-boiling to CHF were clarified. The subcooled boiling heat transfer for Platinum test tube with a commercial finish of inner surface was compared with the values calculated by other workers’ correlations for the subcooled boiling heat transfer. The influence of exponential period (τ) and flow velocity (u) on the subcooled boiling heat transfer is investigated into details and the predictable correlation of the subcooled boiling heat transfer for turbulent flow of water in a short vertical tube is derived based on the experimental data for Platinum test tube with a commercial finish of inner surface. The correlation can describe the subcooled boiling heat transfer coefficients obtained in this work within 15% difference.


2001 ◽  
Vol 67 (653) ◽  
pp. 128-134
Author(s):  
Keishi TAKESHIMA ◽  
Terushige FUJII ◽  
Nobuyuki tAKENAKA ◽  
Hitoshi ASANO ◽  
Takamitsu KONDO

Author(s):  
Koichi Hata ◽  
Suguru Masuzaki

The subcooled boiling heat transfer (HT) and the steady-state critical heat fluxes (CHFs) in a short SUS304-tube with twisted-tape insert are systematically measured for mass velocities (G = 4016 to 13850 kg/m2s), inlet liquid temperatures (Tin = 285.82 to 363.96 K), outlet pressures (Pout = 764.76 to 889.02 kPa) and exponentially increasing heat input (Q = Q0exp(t/τ), τ = 8.5 s) by the experimental water loop comprised of a multistage canned-type circulation pump controlled by an inverter. The SUS304 test tube of inner diameter (d = 6 mm), heated length (L = 59.5 mm), effective length (Leff = 49.1 mm), L/d (= 9.92), Leff/d (= 8.18) and wall thickness (δ = 0.5 mm) with average surface roughness (Ra = 3.18 μm) is used in this work. The SUS304 twisted tape with twist ratio, y [= H/d = (pitch of 180° rotation)/d], of 3.39 is used. The relation between inner surface temperature and heat flux for the SUS304-tube with the twisted-tape insert are clarified from non-boiling to CHF. The subcooled boiling heat transfer for SUS304-tube with the twisted-tape insert is compared with our empty SUS304-tube data and the values calculated by our and other workers’ correlations for the subcooled boiling heat transfer. The influences of the twisted-tape insert and the swirl velocity on the subcooled boiling heat transfer and the CHFs are investigated into details and the widely and precisely predictable correlations of the subcooled boiling heat transfer and the CHFs for turbulent flow of water in the SUS304-tube with twisted-tape insert are given based on the experimental data. The correlations can describe the subcooled boiling heat transfer coefficients and the CHFs obtained in this work within −25 to +15% difference.


Author(s):  
Koichi Hata ◽  
Suguru Masuzaki

The subcooled boiling heat transfer and the steady state critical heat fluxes (CHFs) in a short vertical SUS304-tube for the flow velocities (u = 17.28 to 40.20 m/s), the inlet liquid temperatures (Tin = 293.30 to 362.49 K), the inlet pressures (Pin = 842.90 to 1467.93 kPa) and the exponentially increasing heat input (Q = Q0 exp(t/τ), τ = 10 s) were systematically measured by the experimental water loop comprised of a multistage canned-type circulation pump with high pump head. The SUS304 test tubes of inner diameters (d = 3 and 6 mm), heated lengths (L = 33 and 59.5 mm), effective lengths (Leff = 23.3 and 49.1 mm), L/d (= 11 and 9.92), Leff/d (= 7.77 and 8.18), and wall thickness (δ = 0.5 mm) with average surface roughness (Ra = 3.18 μm) are used in this work. The inner surface temperature and the heat flux from non-boiling to CHF were clarified. The subcooled boiling heat transfer for SUS304 test tube was compared with our Platinum test tube data and the values calculated by other workers’ correlations for the subcooled boiling heat transfer. The influence of flow velocity on the subcooled boiling heat transfer and the CHF is investigated into details and the widely and precisely predictable correlation of the subcooled boiling heat transfer for turbulent flow of water in a short vertical SUS304-tube is given based on the experimental data. The correlation can describe the subcooled boiling heat transfer coefficients obtained in this work within 15% difference. Nucleate boiling surface superheats for the SUS304 test tube become very high. Those at the high liquid Reynolds number are close to the lower limit of Heterogeneous Spontaneous Nucleation Temperature. The dominant mechanisms of the flow boiling CHF in a short vertical SUS304-tube are discussed.


Author(s):  
Koichi Hata ◽  
Suguru Masuzaki

The subcooled boiling heat transfer (HT) and the steady-state critical heat fluxes (CHFs) in a short SUS304-tube with twisted-tape insert are systematically measured for mass velocities (G = 4016 to 13950 kg/m2s), inlet liquid temperatures (Tin = 285.82 to 363.96 K), outlet pressures (Pout = 764.76 to 889.02 kPa) and exponentially increasing heat input (Q = Q0 exp(t/τ), τ = 8.5 s) by the experimental water loop comprised of a multistage canned-type circulation pump controlled by an inverter. The SUS304 test tube of inner diameter (d = 6 mm), heated length (L = 59.5 mm), effective length (Leff = 49.1 mm), L/d (= 9.92), Leff/d (= 8.18) and wall thickness (δ = 0.5 mm) with average surface roughness (Ra = 3.89 μm) is used in this work. The SUS304 twisted tape with twist ratios, y [= H/d = (pitch of 180° rotation)/d], of 2.39, 3.39 and 4.45 are used. The relations between inner surface temperatures and heat fluxes for the SUS304-tubes with various twisted-tape inserts are clarified from non-boiling to CHF. The subcooled boiling heat transfers for SUS304-tubes with various twisted-tape inserts are compared with our empty SUS304-tube data and the values calculated by our and other workers’ correlations for the subcooled boiling heat transfer. The influences of the twisted-tape insert, the twist ratio and the swirl velocity on the subcooled boiling heat transfer and the CHFs are investigated into details and the widely and precisely predictable correlations of the subcooled boiling heat transfer and the CHFs for turbulent flow of water in the SUS304-tubes with twisted-tape inserts are given based on the experimental data. The correlations can describe the subcooled boiling heat transfer coefficients and the CHFs obtained in this work within −25 to +15% difference.