Study and Design of Monitoring System of Reactor Coolant Pump in Nuclear Power Plant

Author(s):  
Lei You ◽  
Fuchun Sun ◽  
Pan He ◽  
Hongkun Xu ◽  
Fang Fang

In this paper, we develop a monitoring system of reactor coolant pumps in nuclear power plant (CPS). The safe running of reactor coolant pump is important for nuclear power plant. Based on the Fourier transform (FT) and some algorithm, The data collected from the pump are analyzed. Once the accident happens, it would cause unimaginable outcome. The system will be jumped to failure process mode when the pump has something wrong. The advanced VXI and virtual instrument technology are applied to system, and the reactor coolant pump will be monitored overall so as to assure that the reactor coolant pump runs in safe, which has a significant value to secure the safe operation and reliability of the nuclear plant. The monitoring system will help the operators find fault of reactor coolant pump.

Author(s):  
Zhaohui Ren ◽  
Hui Ma ◽  
He Li ◽  
Guiqiu Song ◽  
Wenjian Zhou

The reactor coolant pump in nuclear power plant is the only revolving equipment in the nuclear power plant. Its functional stability will directly affect the security of nuclear power plant. The coolant pump of a very nuclear plant is examined by using response spectrum analysis to analysis dynamic characteristics and responses aiming at finding the natural frequencies of vibration, modes of vibration and seismic responses, and any possible step which may cause damage of the whole system. The favorable spectrum and unfavorable one are investigated as well. The paper focuses on avoiding the detrimental effects caused by earthquakes, therefore may lay down a theoretical foundation for structural design and installation.


Author(s):  
Huadong Zhu

Nuclear Power Project RCL (reactor coolant loop) is one of the most critical nuclear safety class 1 equipment in PWR nuclear power plant. Filled with borated water, the RCL is a closed loop and serves as pressure boundary incorporating the reactor pressure vessel, steam generator and reactor coolant pump. Since in-service inspection is required for welds of the RCL, the two sides of the welds shall be bored to meet UT (Ultrasonic Testing) inspection requirements. The design standard states that “if the weld is subject to service inspection, the length of the counterbore shall be 2Tmin (Tmin = minimum of wall thickness) for pipe and Tmin for components and fittings. Therefore, the minimal wall thickness of the boring area inside the RCL shall also meet design requirements. Examination of the RCLs delivered to the nuclear power project sites showed that the wall thickness of some parts of the RCL exceed tolerance in varying degrees (the wall thickness is too thin). The RCL borings need to be analyzed to mitigate the negative impact of insufficient wall thickness, maintain RCL wall thickness to the largest extent and meet design requirements. Under the condition of the jobsite data are idealized, this study analyzes the boring plans for the cold leg of loop B at the reactor vessel side for this nuclear power plant Unit 1 NI (Nuclear Island) and discusses the three methods of boring, namely, general boring, taper boring and eccentric boring. It finds that a combination of taper boring and eccentric boring is the optimal plan. This joint boring technique can help achieve the minimal boring wall thickness, reduce the grinding quantity and maintain the required wall thickness, thus resolving the out-of-tolerance issue. In addition, it meets the design requirements, the wall thickness and in-service inspection requirements. Supervision agency approved the application of the joint boring technique to the RCL for the projects. The RCL installation has proved to be a success.


1996 ◽  
Vol 167 (1) ◽  
pp. 91-97 ◽  
Author(s):  
Iuan-Jou Yang ◽  
Mao-Ying Teng ◽  
Wu-Ing Huan ◽  
Yuan-Lung Sun

2016 ◽  
Vol 31 (4) ◽  
pp. 318-326
Author(s):  
Woongbae Kim ◽  
Hyungwook Jang ◽  
Seungjong Oh ◽  
Sangyong Lee

The Fukushima Daiichi nuclear power plant accident shows that natural disasters such as earthquakes and the subsequent tsunamis can cause station blackout for several days. The electric energy required for essential systems during a station blackout is provided from emergency backup batteries installed at the nuclear power plant. In South Korea, in the event of an extended station blackout, the life of these emergency backup batteries has recently been extended from 8 hours to 24 hours at Shin-Kori 5, 6, and APR1400 for design certification. For a battery life of 24 hours, available safety means system, equipment and procedures are studied and analyzed in their ability to cope with an extended station blackout. A sensitivity study of reactor coolant pump seal leakage is performed to verify how different seal leakages could affect the system. For simulating extended station blackout scenarios, the best estimate MARS-KS computer code was used. In this paper, an APR1400 RELAP5 input deck was developed for station blackout scenario to analyze operation strategy by manually depressurizing the reactor coolant system through the steam generator's secondary side. Additionally, a sensitivity study on reactor coolant pump seal leakage was carried out.


2003 ◽  
Vol 43 (1-4) ◽  
pp. 397-404 ◽  
Author(s):  
K. Nabeshima ◽  
T. Suzudo ◽  
S. Seker ◽  
E. Ayaz ◽  
B. Barutcu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document