Study of thermal lens effect induced by Ar ion laser in ethanol and determination of thermal lens focal length

2013 ◽  
Author(s):  
Mohammad H. Mahdieh ◽  
S. Ahmad Ashrafi ◽  
Hamed Moradi
1985 ◽  
Vol 57 (4) ◽  
pp. 861-864 ◽  
Author(s):  
Jan A. Alfheim ◽  
Cooper H. Langford

2006 ◽  
Vol 266 (2) ◽  
pp. 620-626 ◽  
Author(s):  
Shuzhen Fan ◽  
Xingyu Zhang ◽  
Qingpu Wang ◽  
Shutao Li ◽  
Shuanghong Ding ◽  
...  

1988 ◽  
Vol 42 (2) ◽  
pp. 341-346 ◽  
Author(s):  
G. Ramis Ramos ◽  
M. C. Garcia Alvarez-Coque ◽  
B. W. Smith ◽  
N. Omenetto ◽  
J. D. Winefordner

A pump-probe thermal lens instrument was constructed, evaluated, and applied to the determination of metals after extraction with dithizone in carbon tetrachloride. An argon-ion laser operated at 514.5 nm, with a power of just 22 mW at the cuvette position and chopped at 2 Hz, and a He-Ne laser were used as a pump and probe, respectively. The thermal lens effect was measured by a pinhole-photodiode and a lock-in amplifier. Evaluation of the setup with an iodine solution in carbon tetrachloride gave a minimum detectable absorbance of 5 × 10−6 (S/N = 3), the upper limit of the dynamic range being 5.7 × 10−3. Relative standard deviation was about 3%. Calibration curves and limits of detection for several metal dithizonates were obtained. From extractions of cadmium dithizonate at concentrations lower than 2 ng mL−1, a LOD of 8 pg mL−1, corresponding to an absolute LOD of 4 fg of cadmium in the probe volume, was achieved.


1990 ◽  
Vol 20 (1) ◽  
pp. 52-53
Author(s):  
A I Larkin ◽  
Yu A Mironov ◽  
V M Petropavlovskiĭ

Author(s):  
Yuantao Zhao ◽  
Shengzhi Zhao ◽  
Tao Li ◽  
Yizhou Liu ◽  
Chun Wang ◽  
...  

Abstract Directly measuring thermal focal length is important for designing and optimizing the mode locking oscillator, especially for a 2-μm mode-locking laser. In this paper, we propose a novel interferometric method for measuring the thermal focal length in a 2-μm mode-locking laser. This method could give a precise measurement of the thermal focal length inside a long-folded oscillator in both lasing and non-lasing operation. We also theoretically calculate the thermal focal length based on the temperature distribution inside the laser crystal, which matches well with the experimental result


2010 ◽  
Vol 37 (11) ◽  
pp. 2780-2783
Author(s):  
丁欣 Ding Xin ◽  
李雪 Li Xue ◽  
盛泉 Sheng Quan ◽  
李斌 Li Bin ◽  
周睿 Zhou Rui ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document