Terahertz polarization rotator based on silicon asymmetrical structure

2021 ◽  
Author(s):  
Wentao Deng ◽  
Liao Chen ◽  
Yu Yu ◽  
Xiaojun Wu ◽  
Xinliang Zhang
Author(s):  
R.A Walker ◽  
S. Inoue ◽  
E.D. Salmon

Microtubules polymerized in vitro from tubulin purified free of microtubule-associated proteins exhibit dynamic instability (1,2,3). Free microtubule ends exist in persistent phases of elongation or rapid shortening with infrequent, but, abrupt transitions between these phases. The abrupt transition from elongation to rapid shortening is termed catastrophe and the abrupt transition from rapid shortening to elongation is termed rescue. A microtubule is an asymmetrical structure. The plus end grows faster than the minus end. The frequency of catastrophe of the plus end is somewhat greater than the minus end, while the frequency of rescue of the plus end in much lower than for the minus end (4).The mechanism of catastrophe is controversial, but for both the plus and minus microtubule ends, catastrophe is thought to be dependent on GTP hydrolysis. Microtubule elongation occurs by the association of tubulin-GTP subunits to the growing end. Sometime after incorporation into an elongating microtubule end, the GTP is hydrolyzed to GDP, yielding a core of tubulin-GDP capped by tubulin-GTP (“GTP-cap”).


2021 ◽  
pp. 127145
Author(s):  
Danfeng Zhu ◽  
Han Ye ◽  
Yumin Liu ◽  
Jing Li ◽  
Zhongyuan Yu
Keyword(s):  

IEEE Access ◽  
2021 ◽  
pp. 1-1
Author(s):  
Ahmed Abdelmottaleb Omar ◽  
Abdelhady Mahmoud ◽  
Jaehong Choi ◽  
Wonbin Hong
Keyword(s):  

1974 ◽  
Vol 52 (22) ◽  
pp. 3723-3727 ◽  
Author(s):  
Roger M. Leblanc ◽  
Geneviève Galinier ◽  
Alain Tessier ◽  
Lise Lemieux

A device has been set up to determine quantitatively the weak fluorescence intensities of pigment molecules. It consists of a laser spectrofluorimeter. The excitation beam can be produced with either a He/Cd laser (441.6 nm) or a He/Ne laser (632.8 nm). This system allows us to detect the fluorescence of dilute chlorophyll a or b solutions of the order of 10−12 mol/l. This sensitivity also permits the study of the emission spectra from chlorophyll in monomolecular or solid states, and since a polarization rotator has been incorporated into our apparatus, one may presume some possible orientation of the molecules.


2017 ◽  
Vol 35 (11) ◽  
pp. 2190-2199 ◽  
Author(s):  
Mohamed Farhat O. Hameed ◽  
Firas Faeq K. Hussain ◽  
Salah S. A. Obayya

Optik ◽  
2015 ◽  
Vol 126 (24) ◽  
pp. 5587-5592 ◽  
Author(s):  
Sengul Gonulal ◽  
Muharrem Karaaslan ◽  
Emin Unal ◽  
Kemal Delihacioglu ◽  
Furkan Dincer ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document