Raman fiber amplifier with signal-to-noise ratio enhancement using second Stokes control pulses and effect of double Rayleigh back-scattering

2000 ◽  
Author(s):  
Nam Seong Kim ◽  
R. Mahendra Prabhu ◽  
Cheng Li ◽  
Jie Song ◽  
Deyuan Shen ◽  
...  
Optik ◽  
2014 ◽  
Vol 125 (11) ◽  
pp. 2572-2576 ◽  
Author(s):  
Arwa H. Beshr ◽  
Moustafa H. Aly ◽  
A.K. AboulSeoud

2000 ◽  
Vol 70 (2) ◽  
pp. 169-173
Author(s):  
N.S. Kim ◽  
M. Prabhu ◽  
C. Li ◽  
J. Song ◽  
D. Shen ◽  
...  

2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Seyyed Hossein Kazemi ◽  
Ali Jebelli ◽  
Leila Sirzad

AbstractWe have introduced the comprehensive optical-to-noise ratio (OSNR) to investigate simultaneously the effects of all three major linear noise sources in distributed Raman fiber amplifier (DRFA). The total noise power contains double Rayleigh backscattering (DRB) noise, amplified spontaneous emission (ASE) noise, and relative intensity noise (RIN). Also, we have introduced an approximated gain profile approach, which helps in evaluating the OSNR for higher-order pumping (HOP) configuration for backward, forward, and bidirectional DRFA schemes. Finally, by applying the dynamic and static full-numerical computations on a system of eight wavelength division multiplexing (WDM) channels (for amplifier lengths of 70, 140, and 210 km), we demonstrated that for RIN frequencies greater than 100 kHz, the higher-order bidirectional pumping scheme exceeds the backward schemes by 12 dB.


Author(s):  
David A. Grano ◽  
Kenneth H. Downing

The retrieval of high-resolution information from images of biological crystals depends, in part, on the use of the correct photographic emulsion. We have been investigating the information transfer properties of twelve emulsions with a view toward 1) characterizing the emulsions by a few, measurable quantities, and 2) identifying the “best” emulsion of those we have studied for use in any given experimental situation. Because our interests lie in the examination of crystalline specimens, we've chosen to evaluate an emulsion's signal-to-noise ratio (SNR) as a function of spatial frequency and use this as our critereon for determining the best emulsion.The signal-to-noise ratio in frequency space depends on several factors. First, the signal depends on the speed of the emulsion and its modulation transfer function (MTF). By procedures outlined in, MTF's have been found for all the emulsions tested and can be fit by an analytic expression 1/(1+(S/S0)2). Figure 1 shows the experimental data and fitted curve for an emulsion with a better than average MTF. A single parameter, the spatial frequency at which the transfer falls to 50% (S0), characterizes this curve.


Author(s):  
W. Kunath ◽  
K. Weiss ◽  
E. Zeitler

Bright-field images taken with axial illumination show spurious high contrast patterns which obscure details smaller than 15 ° Hollow-cone illumination (HCI), however, reduces this disturbing granulation by statistical superposition and thus improves the signal-to-noise ratio. In this presentation we report on experiments aimed at selecting the proper amount of tilt and defocus for improvement of the signal-to-noise ratio by means of direct observation of the electron images on a TV monitor.Hollow-cone illumination is implemented in our microscope (single field condenser objective, Cs = .5 mm) by an electronic system which rotates the tilted beam about the optic axis. At low rates of revolution (one turn per second or so) a circular motion of the usual granulation in the image of a carbon support film can be observed on the TV monitor. The size of the granular structures and the radius of their orbits depend on both the conical tilt and defocus.


Author(s):  
D. C. Joy ◽  
R. D. Bunn

The information available from an SEM image is limited both by the inherent signal to noise ratio that characterizes the image and as a result of the transformations that it may undergo as it is passed through the amplifying circuits of the instrument. In applications such as Critical Dimension Metrology it is necessary to be able to quantify these limitations in order to be able to assess the likely precision of any measurement made with the microscope.The information capacity of an SEM signal, defined as the minimum number of bits needed to encode the output signal, depends on the signal to noise ratio of the image - which in turn depends on the probe size and source brightness and acquisition time per pixel - and on the efficiency of the specimen in producing the signal that is being observed. A detailed analysis of the secondary electron case shows that the information capacity C (bits/pixel) of the SEM signal channel could be written as :


Sign in / Sign up

Export Citation Format

Share Document