Role of dispersion profile in controlling emission of dispersive waves by solitons inside optical fibers

2010 ◽  
Author(s):  
Samudra Roy ◽  
S. K. Bhadra ◽  
G. P. Agrawal
2010 ◽  
Vol 283 (15) ◽  
pp. 3081-3088 ◽  
Author(s):  
Samudra Roy ◽  
Debashri Ghosh ◽  
Shyamal K. Bhadra ◽  
Govind P. Agrawal

2014 ◽  
Vol 307 (1) ◽  
pp. H73-H79 ◽  
Author(s):  
Wei Kong ◽  
Vladimir G. Fast

Previous experiments in cultures of neonatal rat myocytes demonstrated that the shape of Cai2+ transients measured using high-affinity Ca2+-sensitive dyes may be misrepresented. The purpose of this study was to examine the role of dye affinity in Cai2+ measurements in intact adult cardiac tissue by comparing optical recordings obtained with high- and low-affinity dyes. Experiments were carried out in porcine left ventricular (LV) wedge preparations stained locally by intramural injection via microcapillaries (diameter = 150 μm) with a low-affinity Ca2+-sensitive dye Fluo-4FF or Fluo-2LA (nominal Kd, ∼7–10 μmol/l), high-affinity dye Rhod-2 ( Kd = 0.57 μmol/l), and Fluo-4 or Fluo-2MA ( Kd, ∼0.4 μmol/l); in addition, tissue was stained with transmembrane potential ( Vm)-sensitive dye RH-237. Optical recordings of Vm and Cai2+ were made using optical fibers (diameter = 325 μm) glued with the microcapillaries. The durations of Cai2+ transients measured at 50% level of recovery (CaD50) using high-affinity Fluo-4/Fluo-2MA dyes were up to ∼81% longer than those measured with low-affinity Fluo-4FF/Fluo-2LA at long pacing cycle lengths (CL). In Fluo-4/Fluo-2MA measurements at long CLs, Cai2+ transients often (∼50% of cases) exhibited slow upstroke rise and extended plateau. In Rhod-2 measurements, CaD50 was moderately longer (up to ∼35%) than in Fluo-4FF recordings, but Cai2+ transient shapes were similar. In all series of measurements, mean action potential duration values were not significantly different ( P > 0.05). The delays between Vm and Cai2+ upstrokes were comparable for low- and high-affinity dyes ( P > 0.05). In conclusion, measurements of Cai2+ transient in ventricular myocardium are strongly affected by the affinity of Ca2+ dyes. The high-affinity dyes may overestimate the duration and alter the shape of Cai2+ transients.


2018 ◽  
Vol 43 (7) ◽  
pp. 1511 ◽  
Author(s):  
T. Marest ◽  
C. Mas Arabí ◽  
M. Conforti ◽  
A. Mussot ◽  
C. Milián ◽  
...  

2020 ◽  
Vol 59 (28) ◽  
pp. 9015
Author(s):  
Surajit Bose ◽  
P. Harshavardhan Reddy ◽  
Jintao Fan ◽  
Ayhan Demircan ◽  
Axel Ruehl ◽  
...  

2002 ◽  
Vol 49 (3) ◽  
pp. 1410-1413 ◽  
Author(s):  
M.O. Zabezhailov ◽  
A.L. Tomashuk ◽  
I.V. Nikolin ◽  
K.M. Golant

2008 ◽  
Vol 39-40 ◽  
pp. 261-264 ◽  
Author(s):  
K.V. Dukel`skii ◽  
A.V. Komarov ◽  
A.V. Khokhlov ◽  
E.V. Ter-Nersesyantz ◽  
V.S. Shevandin

The conception of main role of the lattice pitch value in bend-induced short-wavelength optical losses is presented. There is shown that creation of the fiber core by substitution with seven or nineteen central elements leads to the essential expansion of spectral working range in microstructured large core optical fibers.


Sign in / Sign up

Export Citation Format

Share Document