Biomedical implications of dental-ceramic defects investigated by numerical simulation, radiographic, microcomputer tomography, and time-domain optical coherence tomography

Author(s):  
Cosmin Sinescu ◽  
Meda Lavinia Negrutiu ◽  
Ciprian Ionita ◽  
Liviu Marsavina ◽  
Radu Negru ◽  
...  
2006 ◽  
Vol 38 (6) ◽  
pp. 588-597 ◽  
Author(s):  
H.J. Böhringer ◽  
D. Boller ◽  
J. Leppert ◽  
U. Knopp ◽  
E. Lankenau ◽  
...  

2009 ◽  
Vol 40 (3) ◽  
pp. 325-328 ◽  
Author(s):  
Damien M. Luviano ◽  
Matthew S. Benz ◽  
Rosa Y. Kim ◽  
Richard H. Fish ◽  
Tien P. Wong ◽  
...  

Optical coherence tomography (OCT), which is in use for about 20 years, facilitated the evaluation of the vitreoretinal interface, improved our understanding of its pathologic processes, and paved the way to new treatment approaches. By order of appearance, time-domain, spectral-domain, and swept-source OCT technologies redefined vitreoretinal interface disorders and their treatment modalities.


2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Chunxiao Wang ◽  
Xueying Xia ◽  
Bishan Tian ◽  
Shiyou Zhou

Objective. To compare fourier-domain optical coherence tomography (FD-OCT) and time-domain OCT (TD-OCT) in the determination of thinnest corneal thickness (TCT).Methods. This study included 55 keratoconus patients and 50 healthy volunteers. The RTVue-OCT (FD-OCT) and Visante-OCT (TD-OCT) were used for the measurement of the TCT. Three consecutive scans were performed. The comparison and agreement between the two modalities were analyzed by pairedt-test, the Pearson correlation, intraclass correlation coefficient (ICC), and Bland-Altman plots. intraobserver repeatability was analyzed by the intraobserver within-subject standard deviation (S(w)), coefficient of variation (CV(w)), and ICC.Results. The TCT value of normal corneas was higher by RTVue-OCT (530.4 ± 19.7 μm) than Visante-OCT (521.5 ± 18.3 μm) (p<0.001). For keratoconus eyes, the TCT was 425.0 ± 58.2 μm and 424.4 ± 55.7 μm (difference being 0.6 ± 10.2 μm,p=0.604). Strong correlation (r= 0.938∼0.985) (ICC = 0.915–0.984) was observed between the two OCTs, and each OCT exhibited excellent repeatability in determining the TCT in all subjects (ICC = 0.984–0.994).Conclusions. The values of TCT obtained from RTVue-OCT and Visante-OCT were highly correlated; however, the two values were different. Both OCT instruments exhibited good intraobserver reliability. The existence of systematic differences suggested that the two instruments cannot be used interchangeably.