Computed Tomography (CT) And Picture Archiving And Communication Systems (PACS)

1982 ◽  
Author(s):  
William R. Edens
10.2196/18367 ◽  
2020 ◽  
Vol 3 (2) ◽  
pp. e18367
Author(s):  
David Dallas-Orr ◽  
Yordan Penev ◽  
Robert Schultz ◽  
Jesse Courtier

Background Picture archiving and communication systems (PACS) are ubiquitously used to store, share, and view radiological information for preoperative planning across surgical specialties. Although traditional PACS software has proven reliable in terms of display accuracy and ease of use, it remains limited by its inherent representation of medical imaging in 2 dimensions. Augmented reality (AR) systems present an exciting opportunity to complement traditional PACS capabilities. Objective This study aims to evaluate the technical feasibility of using a novel AR platform, with holograms derived from computed tomography (CT) imaging, as a supplement to traditional PACS for presurgical planning in complex surgical procedures. Methods Independent readers measured objects of predetermined, anthropomorphically correlated sizes using the circumference and angle tools of standard-of-care PACS software and a newly developed augmented reality presurgical planning system (ARPPS). Results Measurements taken with the standard PACS and the ARPPS showed no statistically significant differences. Bland-Altman analysis showed a mean difference of 0.08% (95% CI –4.20% to 4.36%) for measurements taken with PACS versus ARPPS’ circumference tools and –1.84% (95% CI –6.17% to 2.14%) for measurements with the systems’ angle tools. Lin’s concordance correlation coefficients were 1.00 and 0.98 for the circumference and angle measurements, respectively, indicating almost perfect strength of agreement between ARPPS and PACS. Intraclass correlation showed no statistically significant difference between the readers for either measurement tool on each system. Conclusions ARPPS can be an effective, accurate, and precise means of 3D visualization and measurement of CT-derived holograms in the presurgical care timeline.


2020 ◽  
Author(s):  
David Dallas-Orr ◽  
Yordan Penev ◽  
Robert Schultz ◽  
Jesse Courtier

BACKGROUND Picture archiving and communication systems (PACS) are ubiquitously used to store, share, and view radiological information for preoperative planning across surgical specialties. Although traditional PACS software has proven reliable in terms of display accuracy and ease of use, it remains limited by its inherent representation of medical imaging in 2 dimensions. Augmented reality (AR) systems present an exciting opportunity to complement traditional PACS capabilities. OBJECTIVE This study aims to evaluate the technical feasibility of using a novel AR platform, with holograms derived from computed tomography (CT) imaging, as a supplement to traditional PACS for presurgical planning in complex surgical procedures. METHODS Independent readers measured objects of predetermined, anthropomorphically correlated sizes using the circumference and angle tools of standard-of-care PACS software and a newly developed augmented reality presurgical planning system (ARPPS). RESULTS Measurements taken with the standard PACS and the ARPPS showed no statistically significant differences. Bland-Altman analysis showed a mean difference of 0.08% (95% CI –4.20% to 4.36%) for measurements taken with PACS versus ARPPS’ circumference tools and –1.84% (95% CI –6.17% to 2.14%) for measurements with the systems’ angle tools. Lin’s concordance correlation coefficients were 1.00 and 0.98 for the circumference and angle measurements, respectively, indicating almost perfect strength of agreement between ARPPS and PACS. Intraclass correlation showed no statistically significant difference between the readers for either measurement tool on each system. CONCLUSIONS ARPPS can be an effective, accurate, and precise means of 3D visualization and measurement of CT-derived holograms in the presurgical care timeline.


2004 ◽  
Author(s):  
Χρυσόστομος-Αλέξιος Κελέκης

Οι ηλεκτρονικοί υπολογιστές αποτελούν πλέον τμήμα της ακτινολογίας, με τη χρήση των σύγχρονων απεικονιστικών μηχανημάτων. Η δημιουργία συστημάτων ηλεκτρονικής αρχειοθέτησης και επεξεργασίας ψηφιακών εικόνων (Picture Archiving and Communication Systems - PACS), είναι μια πραγματικότητα. Η μελέτη που πραγματοποιήθηκε αφορά στο σχεδιασμό, στην οργάνωση και στη δημιουργία ενός ψηφιακού ακτινολογικού αρχείου. Έτσι είναι δυνατή η σύνδεση αρχαιότερης γενιάς ακτινολογικών μηχανημάτων τα οποία, αν και ψηφιακά, δεν είναι συμβατά με τα σύγχρονα διεθνή πρωτόκολλα επικοινωνίας (DICOM), με αποτέλεσμα την αδυναμία ανεύρεσης κοινού κώδικα επικοινωνίας.ΣΚΟΠΟΣ: Η δημιουργία ενός ολοκληρωμένου δικτύου μεταφοράς εικόνας και κειμένου (PACS), για διακίνηση της πληροφορίας μέσα στο ακτινολογικό εργαστήριο. Αρχικά, το σύστημα θα λειτουργήσει για ερευνητικό και εκπαιδευτικό σκοπό και στη συνέχεια, στην καθημερινή εργαστηριακή χρήση σε πρωτόκολλο DICOM. Το σύστημα αυτό πρέπει να έχει τη δυνατότητα αποθήκευσης των ακτινολογικών εξετάσεων, ανεξαρτήτως ψηφιακού ακτινολογικού μηχανήματος, με εύκολο και προσβάσιμο τρόπο.ΥΛΙΚΟ ΚΑΙ ΜΕΘΟΔΟΣ: Έγινε απογραφή και ανάλυση της υπάρχουσας απεικονιστικής τεχνολογίας. Επακολούθησε ο σχεδιασμός και η ανάλυση των προδιαγραφών του συστήματος. Κατά την εφαρμογή της πρότυπης μονάδος, η μεταφορά της εικόνας γίνεται μέσω δικτύου, από τα ακτινολογικά μηχανήματα σε μια πύλη που αναλαμβάνει να στείλει την πληροφορία-εικόνα σε μια μονάδα, υπό μορφή ηλεκτρονικού μηνύματος. Ο υπολογιστής αυτός, αναλαμβάνει την προσωρινή αποθήκευση του μηνύματος, μέχρι τη στιγμή που ο χρήστης θα διαχωρίσει την εικόνα από το μήνυμα και θα την αρχειοθετήσει. Τέλος, η τεχνογνωσία που αποκτήθηκε από την πρώτη εφαρμογή και η εξέλιξη της τεχνολογίας, επέτρεψαν την αναβάθμιση της πρότυπης μονάδος με την μετατροπή της αρχικής εικόνας από κώδικα TIFF σε DICOM και τη δημιουργία βάσεως δεδομένων.ΑΠΟΤΕΛΕΣΜΑΤΑ: Στην αρχική μορφή, το σύστημα λειτούργησε κυρίως για μεταφορά εκπαιδευτικά χρήσιμων εικόνων σε οπτικούς δίσκους. Η αναβάθμιση του συστήματος επέτρεψε τη δημιουργία βάσεως δεδομένων. Για το χρονικό διάστημα 10/2002-10/2003 έχουν αρχειοθετηθεί 6800 Αξονικές τομογραφίες, που αποτελούν το 98,6% του συνολικού αριθμού των καταγεγραμμένων εξετάσεων (6893) που πραγματοποιήθηκαν, σύμφωνα με τα πεπραγμένα στο Β’ Εργαστήριο Ακτινολογίας του Πανεπιστημίου Αθηνών. Ο αριθμός των ψηφιακά αρχειοθετημένων αγγειογραφιών για το ίδιο διάστημα είναι 1520, έναντι 1545 που υπάρχουν καταγεγραμμένες στα πεπραγμένα, ποσοστό GÇ%. Συνολικά, το 9ÄJ% των πράξεων του Αξονικού τομογράφου και αγγειογράφου είναι ψηφιακά διαθέσιμο, ένα χρόνο αργότερα.ΣΥΜΠΕΡΑΣΜΑΤΑ: Σύμφωνα με τη διεθνή βιβλιογραφία, είναι δυνατόν ένα εργαστήριο να λειτουργεί χωρίς τη χρήση συμβατικών φιλμ, αποθηκεύοντας όλες τις εξετάσεις σε ηλεκτρονική μορφή. Οι τεχνικές αυτές επιτρέπουν την εύκολη σύγκριση και επεξεργασία των ψηφιακά αρχειοθετημένων εικόνων και μειώνουν τις δαπανηρές συνθήκες κατασκευής και συντήρησης αναλογικού αρχείου ακτινολογικών φιλμ.