scholarly journals Laboratory Evaluation of the Liat HIV Quant (IQuum) Whole-Blood and Plasma HIV-1 Viral Load Assays for Point-of-Care Testing in South Africa

2015 ◽  
Vol 53 (5) ◽  
pp. 1616-1621 ◽  
Author(s):  
Lesley Scott ◽  
Natasha Gous ◽  
Sergio Carmona ◽  
Wendy Stevens
2015 ◽  
Vol 105 (3) ◽  
pp. 228 ◽  
Author(s):  
Tyler Joseph Maiers ◽  
Natasha Gous ◽  
Matilda Nduna ◽  
Sally M McFall ◽  
David M Kelso ◽  
...  

Author(s):  
Gary Brook ◽  
Tetiana Stepchenkova ◽  
Innocent M. Ali ◽  
Sandra Chipuka ◽  
Neha Goel ◽  
...  

Remote areas of many low and middle income (LMI) countries have poor access to HIV viral load (HIV VL) testing. The SAMBA-II (Simple Amplification-based Assay) Semi-Q Whole Blood Test (Diagnostics for the Real World (DRW), Cambridge, UK) is a point of care assay which uses leucodepletion technology to allow whole blood testing in remote settings. 1540 consecutive HIV-positive clinic patients in Cameroon (250), UK (633), Ukraine (412) and Zimbabwe (245) donated venous blood (all countries) and finger-prick blood (all except UK) for testing on SAMBA-II. SAMBA II results were compared with simultaneous plasma results on the Abbott RealTime HIV-1 (Abbott Molecular, Des Plaines, IL) viral load assay and interpreted as either <1000 RNA copies/ml or ≥1000 RNA copies/ml. For 1528 venous whole-blood samples tested on SAMBA II, overall percent agreement with the reference test at a cut-off of HIV VL ≥1000 cps/ml was 96.9% (1480/1528 95% CI 95.9-97.7), negative percent agreement 97.7% (1259/1289 95% CI 96.7-98.4), positive percent agreement 92.5% (221/239 95% CI 88.4-95.5). For 854 finger-prick samples there was 95.0% (811/854 95% CI 93.3-96.3) overall percent agreement; negative percent agreement 98.0% (625/638, 95% CI 96.5-98.9); positive percent agreement 86.1% (186/216 95% CI 80.8-90.4). These rose to 93.5% (82.1, 98.6), 97.6% (95.6, 98.8) and 95.6% (93.3, 97.3) after exclusion of aberrant results from the Ukraine centre. These results show a high level of agreement between SAMBA-II and a laboratory-based assay. SAMBA-II has a performance that is suitable to use as a VL point of care assay in remote settings


2014 ◽  
Vol 53 (4) ◽  
pp. 1080-1086 ◽  
Author(s):  
Logan Titchmarsh ◽  
Clement Zeh ◽  
Thierry Verpoort ◽  
Jean-Pierre Allain ◽  
Helen Lee

In order to limit the interference of HIV-1 cellular nucleic acids in estimating viral load (VL), the feasibility of leukodepletion of a small whole-blood (WB) volume to eliminate only leukocyte cell content was investigated, using a selection of filters. The efficacy of leukocyte filtration was evaluated by counting, CD45 quantitative PCR, and HIV-1 DNA quantification. Plasma HIV-1 was tested by real-time reverse transcription (RT)-PCR. A specific, miniaturized filter was developed and tested for leukocyte and plasma virus retention, WB sample dilution, and filtration parameters in HIV-1-spiked WB samples. This device proved effective to retain >99.9% of white blood cells in 100 μl of WB without affecting plasma VL. The Samba sample preparation chemistry was adapted to use a leukodepleted WB sample for VL monitoring using the point-of-care Samba-1 semiautomated system. The clinical performance of the assay was evaluated by testing 207 consecutive venous EDTA WB samples from HIV-1-infected patients attending a CD4 testing clinic. Most patients were on antiretroviral treatment (ART), but their VL status was unknown. Compared to the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test, the new Samba assay had a concordance of 96.5%. The use of the Samba system with a VL test for WB might contribute to HIV-1 ART management and reduce loss-to-follow-up rates in resource-limited settings.


2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
B. Meggi ◽  
T. Bollinger ◽  
A. Zitha ◽  
C. Mudenyanga ◽  
A. Vubil ◽  
...  

2019 ◽  
Vol 121 ◽  
pp. 104202
Author(s):  
Priska Bwana ◽  
Joshua Ageng’o ◽  
Jeff Danda ◽  
Joseph Mbugua ◽  
Allan Handa ◽  
...  

2019 ◽  
Vol 6 (Supplement_2) ◽  
pp. S868-S868
Author(s):  
Sabina Holland ◽  
Allison DeLong ◽  
Tao Liu ◽  
Anna Makaretz ◽  
Mia Coetzer ◽  
...  

Abstract Background Cost still limits HIV-1 viral load (VL) routine monitoring in resource limited settings (RLS), preventing early detection of virologic failure (VF). Pooled VL testing reduces cost over individual testing (IND). We previously showed in simulation, that additional cost benefits over previously-used pooling deconvolution algorithms can be achieved by using low-cost, routinely-collected clinical markers to determine the order for VL testing in deconvolution (termed marker-assisted minipool plus algorithm; mMPA). This algorithm has not been assessed in-vitro. Methods 150 samples from 99 Ghanaian adults with HIV on first-line therapy (VF 17%; CD4-VL correlation −0.35) were used to construct 30, 5-sample pools: n = 10 with 0, n = 5 with 1, and n = 15 with 2 individuals with VF. VL testing was with Abbott M2000. Accuracy, number of tests and rounds of testing to deconvolute pools were estimated using four strategies: (1) IND; (2) Minipooling (MP); (3) Minipooling with algorithm (MPA); and (4) mMPA. Results Compared with IND, MP and MPA, mMPA reduced total number of tests per pool needed to ascertain VF: MP average 4.3 (95% confidence interval (CI) 3.5–5.2, p> 0.05), MPA 3.0 (95% CI 2.4–3.5, P < 0.001), and mMPA 2.5 (CI 2.0–3.0, P < 0.001). Compared with MP and MPA, mMPA further reduced VL tests by 42% (1.9 tests/pool, CI 1.3–2.4, P < 0.001) and 17% (0.5, CI 0.2–0.8, p = 0.004); and required fewer testing rounds than MPA by 17% (P < 0.01), thus producing results quicker. IND and MP had 100% sensitivity and specificity. MPA and mMPA had similar sensitivity of 96.1% (MPA CI 90.7–100%; mMPA CI 88.0–100.0%) and specificity of 99.5% and 99.2% (98.5–100.0% for MPA and 97.5–100.0% for mMPA). Specifically, 3/150 samples were misclassified with MPA and mMPA: one suppression as VF, and two VF as suppressed. Conclusion Laboratory evaluation confirms that deconvolution using mMPA with CD4 or other routinely-collected clinical information as low-cost biomarkers reduces the number of VL assays required to identify VF in a setting with a low prevalence of VF. Implementation of pooled VL testing using mMPA for deconvolution may increase the availability of VL monitoring in RLS. Work is ongoing to reduce complexity and misclassification, required prior to widespread implementation. Disclosures All authors: No reported disclosures.