Sensitive microplate enzyme-linked immunosorbent assay for detection of antibodies against the scrub typhus rickettsia, Rickettsia tsutsugamushi

1979 ◽  
Vol 9 (1) ◽  
pp. 38-48 ◽  
Author(s):  
G A Dasch ◽  
S Halle ◽  
A L Bourgeois

A microtiter enzyme-linked immunosorbent assay (ELISA) has been developed for the titration of antibodies against scrub typhus in human and animal sera. Scrub typhus rickettsiae were grown in monolayers of irradiated mouse LM3 cells and separated from host cell materials by differential centrifugation, filtration through a glass filter (AP-20, Millipore Corp.), and isopycnic banding in Renografin density gradients. The scrub typhus ELISA antigens were obtained from the purified viable rickettsiae by French pressure cell disruption and addition of 0.2% Formalin to the soluble extract. Antisera prepared in rabbits against the prototype Karp, the Kato, and the Gilliam strains of scrub typhus were used to standardize the ELISA and to compare its sensitivity and specificity to that of the indirect fluorescent antibody test (IFA). ELISA titers were measured as the greatest serum dilution showing an optical density 0.25 above controls or by the optical density achieved at a fixed serum dilution. The IFA and ELISA end point titers were quite similar, and all three measures of titer had comparable specificity for the strains of scrub typhus. No cross-reactions between the typhus and scrub typhus wera were observed by ELISA. Both the immunoglobulin M (IgM) and IgG antibody titers of 12 sequential sera from four patients with scrub typhus were obtained by IFA and ELISA. The IFA and ELISA end point titers for IgM and IgG had correlation coefficients of 0.91 and 0.97, respectively, whereas the ELISA optical density values at a serum dilution of 1:100 had slightly lower correlations with IFA titers (0.80 and 0.94). Early rising IgM titers followed by rising IgG titers were demonstrated by ELISA in three patients with primary scrub typhus infections, whereas the IgG response predominated in a patient with a reinfection. It is concluded that the ELISA for scrub typhus is a very satisfactory alternative to the IFA test.

1989 ◽  
Vol 1 (2) ◽  
pp. 124-127 ◽  
Author(s):  
Sheryl L. Seefeldt ◽  
Clyde A. Kirkbride ◽  
Jitender P. Dubey

Results obtained in an enzyme-linked immunosorbent assay (ELISA), an indirect fluorescent antibody test (IFA), and a modified direct agglutination test (MAT) for Toxoplasma gondii antibodies from examination of fetal fluids from 377 aborted ovine fetuses were compared. Sixty-seven samples were positive by MAT (titers 1:16 to > 1:65,536), 58 were positive by ELISA, and 62 were positive by immunoglobulin G-IFA. The MAT was preferred because it required less time, labor, and special equipment. It was simple to run, could be done on serum from any species without modification, and it was more effective than the IFA for detecting toxoplasma antibodies in severely autolyzed fetuses. No advantage was found in determining immunoglobulin M antibodies in ovine fetal sera.


2003 ◽  
Vol 10 (3) ◽  
pp. 394-398 ◽  
Author(s):  
Won-Jong Jang ◽  
Myung-Suk Huh ◽  
Kyung-Hee Park ◽  
Myung-Sik Choi ◽  
Ik-Sang Kim

ABSTRACT To differentiate scrub typhus from other acute febrile diseases, a rapid and reliable serological diagnosis is important. We developed an immunoglobulin M (IgM) capture enzyme-linked immunosorbent assay (ELISA) for diagnosis of recent Orientia tsutsugamushi infections in humans. The 56-kDa major outer membrane protein of O. tsutsugamushi is well known as the most immunodominant antigen in scrub typhus. The test is based on the use of the biotinylated recombinant 56-kDa protein of O. tsutsugamushi Boryong, Bor56, which was expressed as a fusion protein with a maltose-binding protein in Escherichia coli. In the test, the serum IgM antibodies were captured by anti-human IgM antibodies coated onto a microtiter plate. The captured IgM antibodies were revealed through sequential addition of biotinylated Bor56 antigen and peroxidase-conjugated streptavidin to the plate. The IgM capture ELISA was compared with the immunofluorescence antibody assay (IFA) by testing 176 serum samples from patients with diagnosed cases of rickettsial disease and patients with other acute febrile diseases. Of the 81 IgG IFA-positive samples, 78 tested positive (sensitivity, 96.3%) and all 31 IgM IFA-positive samples tested positive (sensitivity, 100%) by the IgM capture ELISA. The specificity of the IgM capture ELISA was 99%, and 1 of the 95 IFA-negative samples was positive in the assay. These results strongly suggest that IgM capture ELISA using the recombinant Bor56 antigen is a reliable and detailed method for the detection of early O. tsutsugamushi infection.


1998 ◽  
Vol 36 (12) ◽  
pp. 3474-3479 ◽  
Author(s):  
Marianne J. Mathiesen ◽  
Michael Christiansen ◽  
Klaus Hansen ◽  
Arne Holm ◽  
Eva Åsbrink ◽  
...  

Sera from 210 patients with Lyme borreliosis (LB) were studied by an enzyme-linked immunosorbent assay (ELISA) based on a synthetic peptide (pepC10) comprising the C-terminal 10-amino-acid residues of OspC of Borrelia burgdorferi. We found that 36.3 and 45.0% of the serum samples from patients with erythema migrans (EM) and neuroborreliosis (NB), respectively, displayed immunoglobulin M (IgM) anti-pepC10 reactivities, while these samples rarely (≤8%) displayed IgG antibody reactivities. Sera from patients with acrodermatitis chronica atrophicans did not contain anti-pepC10 antibodies. The diagnostic performance of this newly developed peptide ELISA was compared with those of an ELISA based on the full-length recombinant OspC protein (rOspC) and a commercially available ELISA based on theB. burgdorferi flagellum (Fla). The sensitivity of the IgM pepC10 ELISA was slightly lower (P < 0.04) than that of the rOspC ELISA for EM patients (36.3 versus 43.8%), while there was no difference for NB patients (45.0 versus 48.0%). However, the optical density values obtained by the pepC10 ELISA were generally higher than those obtained by the rOspC ELISA, leading to a significantly better quantitative discrimination between seropositive patients with NB and controls (P < 0.008). The specificity of the pepC10 ELISA was similar to those of the rOspC ELISA and the Fla ELISA for relevant controls including patients with syphilis and mononucleosis. Although the overall diagnostic sensitivity of the Fla ELISA was superior, 8.8 and 12.0% of the EM and NB patients, respectively, were antibody positive only by the pepC10 ELISA. Thus, use of a diagnostic test for LB based on the detection of IgM antibodies to pepC10 and Fla has increased sensitivity for the diagnosis of early LB.