Design and Application of an Optical pH Sensor Based on Thionine Doped Modified Sol–Gel Film

2019 ◽  
Vol 93 (7) ◽  
pp. 1389-1393
Author(s):  
Mahboubeh Vafi ◽  
Gholam Hossein Rounaghi ◽  
Zarrin Es’haghi ◽  
Zahra Moradi
2008 ◽  
Vol 41 (17) ◽  
pp. 3113-3123 ◽  
Author(s):  
Mojtaba Shamsipur ◽  
Fatemeh Abbasitabar ◽  
Vali Zare-Shahabadi ◽  
Shahabadi ◽  
Morteza Akhond

2016 ◽  
Author(s):  
Norliza Othman ◽  
Wan Fazlida Hanim ◽  
Uzer Mohd Noor ◽  
Sukreen Hana

2000 ◽  
Vol 10 (8) ◽  
pp. 1825-1828 ◽  
Author(s):  
Michael H. W. Lam ◽  
Derek Y. K. Lee ◽  
K. W. Man ◽  
Cindy S. W. Lau

2009 ◽  
Vol 7 (1) ◽  
pp. 1-5 ◽  
Author(s):  
Mir Azam Khan ◽  
Seikh Mafiz Alam ◽  
Saikh Mohammad Wabaidur ◽  
Sang Hak Lee ◽  
Yeoun Suk Suh ◽  
...  
Keyword(s):  
Sol Gel ◽  

1995 ◽  
Vol 34 (Part 2, No. 12A) ◽  
pp. L1594-L1596 ◽  
Author(s):  
Yoshihiro Takahashi ◽  
Ryuichi Shimada ◽  
Akinori Maeda ◽  
KenzoKojima ◽  
Hiroshi Ota

2012 ◽  
Vol 21 (3) ◽  
pp. 223-228 ◽  
Author(s):  
Da-Yeong Jeon ◽  
Wook-Jae Yoo ◽  
Sang-Hun Shin ◽  
Ki-Tek Han ◽  
Jang-Yeon Park ◽  
...  
Keyword(s):  
Sol Gel ◽  

1999 ◽  
Author(s):  
Aleksandra Lobnik ◽  
Karlheinz Niederreiter ◽  
Georg Uray
Keyword(s):  
Sol Gel ◽  

Sensors ◽  
2018 ◽  
Vol 18 (10) ◽  
pp. 3195 ◽  
Author(s):  
Jianxin Zhang ◽  
Lei Zhou

Making use of the sol-gel technique, an optical pH sensor was prepared, which was made from an organic carrier with four indictors including congo red, bromophenol blue, cresol red, and chlorophenol red, cross-linked by tetraethyl orthosilicate (TEOS) and cellulose acetate. The actual detection range of the optical pH sensor is 2.5–11.0. The optimal ratio of ethyl orthosilicate, absolute ethanol, deionized water, and hydrochloric acid in glue precursor of the sensor-sensitive membrane was explored. The orthogonal experiment was designed to optimize the dosage of cellulose acetate, N,N-dimethylformamide (DMF), indicator, hydrochloric acid, and precursor glue in preparing the sensor-sensitive membrane. The linearity, measurement accuracy, repeatability, stability, and response time of the prepared pH sensor were tested. The measurement results were analyzed using a support vector machine and linear regression. The experimental results show that the optical pH sensor has a measurement accuracy of up to 0.2 pH and better stability and repeatability than the traditional pH glass electrode.


2013 ◽  
Vol 20 (2) ◽  
pp. 209-213 ◽  
Author(s):  
Dayeong Jeon ◽  
Wook Jae Yoo ◽  
Jeong Ki Seo ◽  
Sang Hun Shin ◽  
Ki-Tek Han ◽  
...  
Keyword(s):  
Sol Gel ◽  

Sign in / Sign up

Export Citation Format

Share Document