Republished: Advanced digital subtraction angiography and MR fusion imaging protocol applied to accurate placement of flow diverter device

2015 ◽  
Vol 8 (2) ◽  
pp. e5-e5 ◽  
Author(s):  
Giuseppe Faragò ◽  
Valentina Caldiera ◽  
Giovanni Tempra ◽  
Elisa Ciceri

In recent years there has been a progressive increase in interventional neuroradiology procedures, partially due to improvements in devices, but also to the simultaneous development of technologies and radiological images. Cone beam CT (Dyna-CT; Siemens) is a method recently used to obtain pseudo CT images from digital subtraction angiography (DSA) with a flat panel detector. Using dedicated software, it is then possible to merge Dyna-CT images with images from a different source. We report here the usefulness of advanced DSA techniques (Syngo-Dyna CT, three-dimensional DSA iPilot) for the treatment of an intracranial aneurysm with a flow diverter device. Merging MR and Dyna-CT images at the end of the procedure proved to be a simple and rapid additional method of verifying the success of the intervention.

2021 ◽  
Author(s):  
Serge Marbacher ◽  
Matthias Halter ◽  
Deborah R Vogt ◽  
Jenny C Kienzler ◽  
Christian T J Magyar ◽  
...  

Abstract BACKGROUND The current gold standard for evaluation of the surgical result after intracranial aneurysm (IA) clipping is two-dimensional (2D) digital subtraction angiography (DSA). While there is growing evidence that postoperative 3D-DSA is superior to 2D-DSA, there is a lack of data on intraoperative comparison. OBJECTIVE To compare the diagnostic yield of detection of IA remnants in intra- and postoperative 3D-DSA, categorize the remnants based on 3D-DSA findings, and examine associations between missed 2D-DSA remnants and IA characteristics. METHODS We evaluated 232 clipped IAs that were examined with intraoperative or postoperative 3D-DSA. Variables analyzed included patient demographics, IA and remnant distinguishing characteristics, and 2D- and 3D-DSA findings. Maximal IA remnant size detected by 3D-DSA was measured using a 3-point scale of 2-mm increments. RESULTS Although 3D-DSA detected all clipped IA remnants, 2D-DSA missed 30.4% (7 of 23) and 38.9% (14 of 36) clipped IA remnants in intraoperative and postoperative imaging, respectively (95% CI: 30 [ 12, 49] %; P-value .023 and 39 [23, 55] %; P-value = <.001), and more often missed grade 1 (< 2 mm) clipped remnants (odds ratio [95% CI]: 4.3 [1.6, 12.7], P-value .005). CONCLUSION Compared with 2D-DSA, 3D-DSA achieves a better diagnostic yield in the evaluation of clipped IA. Our proposed method to grade 3D-DSA remnants proved to be simple and practical. Especially small IA remnants have a high risk to be missed in 2D-DSA. We advocate routine use of either intraoperative or postoperative 3D-DSA as a baseline for lifelong follow-up of clipped IA.


2021 ◽  
Vol 12 ◽  
pp. 85
Author(s):  
Toshihiro Ishibashi ◽  
Fumiaki Maruyama ◽  
Issei Kan ◽  
Tohru sano ◽  
Yuichi Murayama

Background: Intraosseous arteriovenous fistula (AVF) is a rare clinical entity that typically presents with symptoms from their effect on surrounding structures. Here, we report a case of intraosseous AVF in the sphenoid bone that presented with bilateral abducens palsy. Case Description: A previously healthy man presented with tinnitus for 1 month, and initial imaging suspected dural AVF of the cavernous sinus. Four-dimensional digital subtraction angiography (4D-DSA) imaging and a three-dimensional (3D) fused image from the bilateral external carotid arteries revealed that the shunt was in a large venous pouch within the sphenoid bone that was treated through transvenous coil embolization. His symptoms improved the day after surgery. Conclusion: This is a case presentation of intraosseous AVF in the sphenoid bone and highlights the importance of 4D-DSA and 3D fused images for planning the treatment strategy.


2019 ◽  
Vol 61 (1) ◽  
pp. 37-46 ◽  
Author(s):  
Marius Georg Kaschner ◽  
Athanasios Petridis ◽  
Bernd Turowski

Background Treatment of ruptured dissecting and blister aneurysms is technically challenging with potentially high morbidity and mortality. The Derivo Embolisation Device (Derivo) is a flow diverter stent designed for the treatment of intracranial aneurysms. Purpose To assess the safety and feasibility of the Derivo in the treatment of ruptured dissecting and blister aneurysms. Material and Methods We retrospectively analyzed all patients with ruptured dissecting and blister aneurysms treated with the Derivo between February 2016 and July 2018. Procedural details, complications, morbidity within 30 days, and angiographic aneurysm occlusion rates, initially and after six months, were assessed. Results In 10 patients 11 ruptured dissecting and blister aneurysms were treated with 12 Derivos as monotherapy. No aneurysm rebleeding was observed at follow-up. One treatment-related complication occurred including a coil perforation of an additionally treated aneurysm. One patient died due to brain edema. Initial digital subtraction angiography revealed complete (O’Kelly–Marotta [OKM] classification D) and favorable (OKM D+C) occlusion rate in three aneurysms. Six-month follow-up for digital subtraction angiography and clinical evaluation was available in 6/9 patients with complete (OKM D) occlusion in all aneurysms (6/6). Favorable (modified Rankin Scale [mRS] ≤ 2) and moderate (mRS 3) clinical outcome after a mean follow-up of 10 months was observed in six and two patients, respectively. Conclusion Endovascular treatment with the Derivo in ruptured dissecting and blister aneurysms revealed a sufficient initial division of aneurysms from the circulation without rebleeding. The Derivo is associated with high procedural and clinical short-term safety.


Neurosurgery ◽  
2019 ◽  
Vol 87 (4) ◽  
pp. 689-696 ◽  
Author(s):  
Serge Marbacher ◽  
Jenny C Kienzler ◽  
Itai Mendelowitsch ◽  
Donato D’Alonzo ◽  
Lukas Andereggen ◽  
...  

Abstract BACKGROUND Postoperative three-dimensional digital subtraction angiography (3D-DSA) is the gold standard in evaluating intracranial aneurysm (IA) remnants after clipping. Should intraoperative 3D-DSA image quality be equally good as postoperative 3D-DSA, it could supplant the latter as standard of care for follow-up of clipped IA. OBJECTIVE To directly compare the quality of assessment of clipped IA by intraoperative and postoperative 3D-DSA. METHODS From a prospective cohort of 221 consecutive patients who underwent craniotomy for IA treatment in a hybrid operating room, we retrospectively studied 26 patients who had both intraoperative and postoperative 3D-DSA imaging of their clipped aneurysm. Comparison of intraoperative and postoperative 3D-DSA images (blinded for review) included parameters that affected image quality and differences between the 2 periods. RESULTS In the 26 patients with 32 clipped IAs, the mean interval was 11 ± 7 mo between intraoperative and postoperative imaging 3D-DSA examinations. Reconstruction with multiple clips was used in 14 (44%) cases. Of 15 remnants, 9 (60%) were small (<2 mm). In comparing intraoperative and postoperative 3D-DSA, no discordance or discrepancy in assessment of the surgical result was noted for any clipped IA, and overall imaging quality was excellent for both modalities. Factors affecting minor differences in image quality were not identified. CONCLUSION Compared with postoperative 3D-DSA, intraoperative 3D-DSA images achieved equally high quality and effective, immediate interpretation of the surgical clipping result. With comparable imaging quality and no discordant findings, intraoperative 3D-DSA could replace postoperative 3D-DSA to become the standard of care in IA surgery.


Sign in / Sign up

Export Citation Format

Share Document