This paper reports on the potential of using the impact resonance method (IRM) for detecting fatigue damage in strengthened reinforced concrete (RC) beams. In this experimental program, 1.2 m long RC beams strengthened with a carbon fibre reinforced polymer (CFRP) plate have been employed. The specimens were subjected to fatigue loading under four-point bending for up to 2 × 106 cycles at 3 Hz. The load amplitude was varying from 15% to 75% of the cycles yielding load of the beam. Throughout fatigue testing, the cycling was stopped for IRM measurements to be taken. The obtained data provided information about changes in modal properties, such as, fundamental frequencies and damping ratios. Moreover, the results have shown that the IRM technique was successfully employed in laboratory for detecting fatigue damage in concrete beams strengthened with CFRP laminates.Key words: impact resonance method, modal properties, RC beam, FRP-strengthening, fatigue test, cracking.

2008 ◽  
Vol 35 (11) ◽  
pp. 1251-1260 ◽  
Author(s):  
C. Ward ◽  
N. Rattanawangcharoen ◽  
C. Gheorghiu

Much of North America’s civil infrastructure is rapidly aging and, in some cases, exceeding its design life and load. To combat this, the exploration of simple and effective methods for rehabilitation and structural health monitoring has been receiving much attention in industry and academia. This paper reports on the use of the impact resonance method (IRM) for evaluating the structural health of thermal-cycled reinforced concrete (RC) beams with and without externally strengthened carbon-fibre-reinforced polymer (CFRP) pultruded plates. In the experimental program, 1.2 m long specimens were subjected to 55 thermal cycles ranging from +23 to −18 °C. Fatigue loading consisting of up to two million cycles at high and low stress levels was performed. At pre-determined load cycle intervals, the loading was stopped and the IRM was performed on the specimens. Parameters including the appearance of the fast Fourier transform (FFT) spectrum of the specimens’ vibration, modal fundamental frequencies, and dynamic properties were used to assess damage in the specimen. Conclusions were made regarding the use of the IRM in monitoring the health of strengthened and unstrengthened RC beams subjected to thermal and fatigue cycles.


2000 ◽  
Vol 27 (5) ◽  
pp. 1005-1010 ◽  
Author(s):  
Khaled A Soudki ◽  
Ted G Sherwood

The viability of carbon fibre reinforced polymer (CFRP) laminates for the strengthening of corrosion damaged reinforced concrete bridge girders is addressed in this paper. Ten reinforced concrete beams (100 × 150 × 1200 mm) with variable chloride levels (0-3%) were constructed. Six beams were strengthened by externally epoxy bonding CFRP laminates to the concrete surface. The tensile reinforcements of three unstrengthened and four strengthened specimens were subjected to accelerated corrosion by means of impressed current to 5, 10, and 15% mass loss. Strain gauges were placed on the CFRP laminates to monitor and quantify tensile strains induced by the corrosion process. Following the corrosion phase, the specimens were tested in flexure in a four-point bending regime. Test results revealed that CFRP laminates successfully confined the corrosion cracking, and the total expansion of the laminate exhibited an exponential increase throughout the corrosion process. All the strengthened beams exhibited increased stiffness over the unstrengthened specimens and marked increases in the yield and ultimate strength. The CFRP strengthening scheme was able to restore the capacity of corrosion damaged concrete beams up to 15% mass loss.Key words: CFRP laminates, corrosion, confinement, expansion, load tests, strengthening, bond strength, reinforced concrete.


2005 ◽  
Vol 32 (5) ◽  
pp. 812-824 ◽  
Author(s):  
Francesco Bencardino ◽  
Vincenzo Colotti ◽  
Giuseppe Spadea ◽  
Ramnath Narayan Swamy

The aim of this paper is to clarify the structural performance of reinforced concrete (RC) beams with weak or without any internal shear reinforcement and externally strengthened in flexure with carbon fibre reinforced polymer (CFRP) laminates, when subjected to a shear-dominant-loading regime. Seven RC beams were specifically designed, without and with an external anchorage system, which was carefully detailed to enhance the benefits of the strengthening laminate and counteract the destructive effects of shear forces. All the beams were identical in terms of their geometry, longitudinal internal reinforcement, and concrete strength but varied, to highlight the role of shear behavior, in terms of their internal and external shear reinforcement as well as in their loading test regime. The beams were tested under four-point bending and extensively instrumented to monitor strains, deflection, cracking, load carrying capacity, and failure modes. The structural response of the tested beams has, then, been critically analyzed in terms of deformability, strength, and failure processes that occur under a shear-dominant loading regime. It is shown that with a carefully designed anchorage system, a brittle behavior without yielding of tension steel reinforcement of a flexural strengthened beam can be transformed to a less brittle behavior with yielding of tension steel reinforcement and a well-defined enhancement of structural performance in terms of both deformation and strength. The results presented in this paper should enable engineers to counteract shear failure of externally strengthened beams with little or even no internal shear reinforcement.Key words: carbon fibre reinforced polymer, shear behavior, external flexural strengthening, structural performance.


Concrete, a mixture of different aggregates bonded with cement, first developed around 150BC in Rome has been bedrock to the modern Infrastructure. It is used to build everything from roads, bridges, dams to sky scrapers. Strengthening concrete is traditionally done by using steels but the developments in technology in recent decades allowed to use fiber reinforced plastics which are externally bonded to concrete . Such composite materials offer high strength, low weight, corrosion resistance, high fatigue resistance, easy and rapid installation and minimal change in structural geometry. This study investigates the behavior of reinforced concrete beams bonded with fiber composites. A numerical study is conducted to study the behavior of RC beam under Static third point loading. Concrete beam specimens with dimensions of 150 mm width, 300 mm height, and 2600 mm length are modelled. These beams are externally bonded with Glass Fiber Reinforced Polymer (GFRP) sheets and Carbon Fibre Reinforced Polymer (CFRP) sheets. In present study, we examine the performance of reinforced concrete beams which are bonded with GFRP and CFRP sheets with various thicknesses (1, 2 & 3 mm) using ABAQUS in terms of failure modes, enhancement of load capacity, load-deflection analysis and flexural behaviour