Fluid-Structure Interaction Analysis of Bioprosthetic Heart Valve

Author(s):  
B.S. Shen ◽  
Q. Yuan ◽  
X. Zhang ◽  
X. Zhang
Author(s):  
Esfandyar Kouhi ◽  
Yos Morsi

In this paper the fluid structure interaction in stentless aortic heart valve during acceleration phase was performed successfully using the commercial ANSYS/CFX package. The aim is to provide unidirectional coupling FSI analysis of physiological blood flow within an anatomically corrected numerical model of stentless aortic valve. Pulsatile, Newtonian, and turbulent blood flow rheology at aortic level was applied to fluid domain. The proposed structural prosthesis had a novel multi thickness leaflet design decreased from aortic root down to free age surface. An appropriate interpolation scheme used to import the fluid pressure on the structure at their interface. The prosthesis deformations over the acceleration time showed bending dominant characteristic at early stages of the cardiac cycle. More stretching and flattening observed in the rest of the times steps. The multi axial Von Mises stress data analysis was validated with experimental data which confirmed the initial design of the prosthesis.


2014 ◽  
Vol 472 ◽  
pp. 125-130 ◽  
Author(s):  
Quan Yuan ◽  
Xin Ye

The object of this study is to utilize FE-SPH method to simulate the dynamic behavior of bioprosthetic heart valve during systole. Two kind of bioprosthetic heart valve numerical models are designed based on membrane theory, and they are represented by FE mesh, the blood is modelled as SPH particles. The interaction between the blood and bioprosthetic heart valve is carried out with contact algorithms. Results show that: when the valve leaflets are opening, compared with that of spherical valve, the stress and strain states of cylindrical valve are unstable, and the peak Von Mises is also higher, which high peak stress and its instability may induce the fatigue of valve. The valve opening time of columnar valve leaflets is longer than that of spherical ones, which reduces the blood ejection time. Above results indicate that spherical valve is superior to cylindrical valve. The FE-SPH method is capable of simulating the fluid structure interaction between the bioprosthetic heart valve and blood during the systole.


Author(s):  
Z. C. Wang ◽  
Q. Yuan ◽  
H. W. Zhu ◽  
B. S. Shen ◽  
D. Tang

In this paper, a parametric geometry model based on elliptic and conic surfaces was developed for bioprosthetic heart valve (BHV) simulation. The valve material was modeled by a hyperelastic nonlinear anisotropic solid model. Different suture densities could be substituted by various bonded points between artery vessel and the leaflets as boundary conditions in the computational modeling. Besides these two assumptions that dynamic structure (DS) and fluid–structure interaction (FSI) both shared, the latter need incompressible viscous Newton fluid model to depict bloodstream passing through the BHV. Immersed boundary (IB) method was introduced to solve the FSI simulation. In addition, the DS analysis applied transvalvular pressure on the valve while FSI had left ventricular pressure on fluid inlet as initials. There was inconsistency between the moments of the maximum deformation and the maximum loading in both simulations. Although a similar trend of deformation lagging the load was viewed, the extent of delay in FSI was much smaller compared with that in DS simulation. The deformed profiles in cross-sectional views were shown in one picture to illustrate different dynamic responses caused by distinct assumptions. Percent of open area at the moments when the maximum deformation occurred was defined to show which calculation achieved better approximation for precise hemodynamics. Fixed point was given as boundaries between BHV and artery in the modeling part. Calculations showed that the more the fixed points in this bonded contact, the lower the principal stress was. The maximum shear stress showed a different trend. It had a different trend. Stress concentration in the conjunction area made it high-risk to be teared. Different suture densities had significant impaction in FSI simulations. With that analysis our work achieved a more comprehensive simulation to describe true hemodynamics of a BHV implanted in artery. The artery vessel had particular dynamic response under such assumptions, gradient existed in the maximum principal stress distribution diagram, from inner wall through which blood passing to the outer wall. Results showed a large suture density was suggested in BHV implantation.


Author(s):  
Alejandro Roldán ◽  
Nancy Sweitzer ◽  
Tim Osswald ◽  
Naomi Chesler

Modeling pulsatile flow past heart valves remains a relatively unexplored but critical area. Due to the geometric complexity and the interaction between the flowing blood and the heart valve leaflets, existing numerical techniques that require domain discretization, such as finite element methods or finite difference techniques, cannot fully represent the moving and deforming boundaries present in an operating valve. Our aim is to develop a technique to model the flow through heart valves which includes the interaction between the blood flow and the valve leaflets using the radial functions method (RFM). The RFM is a meshless technique that fully accounts for moving and deforming surfaces and thus is well suited to model the blood flow and its interaction with leaflet motion. Here we present a 2D fluid structure interaction (FSI) model of the blood flow through a bileaflet mechanical heart valve (MHV).