Continuous positive airway pressure causes lung injury in a model of sepsis

2005 ◽  
Vol 289 (4) ◽  
pp. L554-L564 ◽  
Author(s):  
Shinya Tsuchida ◽  
Doreen Engelberts ◽  
Matthias Roth ◽  
Colin McKerlie ◽  
Martin Post ◽  
...  

Continuous positive airway pressure, aimed at preventing pulmonary atelectasis, has been used for decades to reduce lung injury in critically ill patients. In neonatal practice, it is increasingly used worldwide as a primary form of respiratory support due to its low cost and because it reduces the need for endotracheal intubation and conventional mechanical ventilation. We studied the anesthetized in vivo rat and determined the optimal circuit design for delivery of continuous positive airway pressure. We investigated the effects of continuous positive airway pressure following lipopolysaccharide administration in the anesthetized rat. Whereas neither continuous positive airway pressure nor lipopolysaccharide alone caused lung injury, continuous positive airway pressure applied following intravenous lipopolysaccharide resulted in increased microvascular permeability, elevated cytokine protein and mRNA production, and impaired static compliance. A dose-response relationship was demonstrated whereby higher levels of continuous positive airway pressure (up to 6 cmH2O) caused greater lung injury. Lung injury was attenuated by pretreatment with dexamethasone. These data demonstrate that despite optimal circuit design, continuous positive airway pressure causes significant lung injury (proportional to the airway pressure) in the setting of circulating lipopolysaccharide. Although we would currently avoid direct extrapolation of these findings to clinical practice, we believe that in the context of increasing clinical use, these data are grounds for concern and warrant further investigation.

2020 ◽  
Vol 14 (1) ◽  
Author(s):  
Jared Floersch ◽  
Elsa Hauschildt ◽  
Adam Keester ◽  
Samuel Poganski ◽  
Kiet Tran ◽  
...  

Abstract Continuous positive airway pressure (CPAP) is a method of respiratory support used around the world to treat children with lower respiratory tract infections (LRTI) (WHO, 2016, Oxygen Therapy for Children, World Health Organization, Geneva, Switzerland, Report). Bubble continuous positive airway pressure (bCPAP) is an effective form of CPAP that is currently used in both high- and low-resource countries. Low-cost, modified bCPAP devices have been designed as an ideal form of CPAP in low-resource areas (Bjorklund, A. R., Mpora, B. O., Steiner, M. E., Fischer, G., Davey, C. S., and Slusher, T. M., 2018, “Use of a Modified Bubble Continuous Positive Airway Pressure (bCPAP) Device for Children in Respiratory Distress in Low- and Middle-Income Countries: A Safety Study,” Paediatr. Int. Child Health, 39(3), pp. 1–8). However, patients in low-resource settings undergoing bCPAP treatment are often given pure oxygen, which has been linked to retinopathy of prematurity, cardiovascular complications, and patient mortality (Rodgers, J. L., Iyer, D., Rodgers, L. E., Vanthenapalli, S., and Panguluri, S. K., 2019, “Impact of Hyperoxia on Cardiac Pathophysiology,” J. Cell. Physiol., 234(8), pp. 1–9; Ramgopal, S., Dezfulian, C., Hickey, R. W., Au, A. K., Venkataraman, S., Clark, R. S. B., and Horvat, C. M., 2019, “Association of Severe Hyperoxemia Events and Mortality Among Patients Admitted to a Pediatric Intensive Care Unit,” JAMA Network Open, 2(8), p. e199812). This problem is typically avoided by using commercial oxygen blenders, which can titrate down the concentration of oxygen delivered to the minimum needed; however, these blenders can cost nearly 1000 USD and are almost always unavailable in low-resource settings. The lack of available low-cost oxygen blenders compatible with modified bCPAP circuits creates a barrier for low-resource hospitals to be able to provide blended oxygen to patients. There is a need for a low-cost oxygen blender for use in low-resource settings. We propose a passive oxygen blender that operates via entrainment of atmospheric air. The device can easily be assembled in low-resource areas using a 22 gauge hypodermic needle, two 3 cc syringes, tape or super glue, and the materials required for bCPAP—for approximately 1.40 USD per device. The blender has not been clinically tested yet, but can achieve oxygen concentrations as low as 60% with bCPAP levels of 5 cm H2O (490 Pa) when used in a standard bCPAP circuit without a patient.


1978 ◽  
Vol 12 (9) ◽  
pp. 923-926 ◽  
Author(s):  
Alan B Osher ◽  
Barbara Gothe ◽  
D H Simmons ◽  
B Waymost ◽  
H Green

Sign in / Sign up

Export Citation Format

Share Document