scholarly journals Simultaneous Determination of Simvastatin and Ezetimibe in Tablets by HPLC

2009 ◽  
Vol 6 (2) ◽  
pp. 541-544 ◽  
Author(s):  
D. Anantha Kumar ◽  
D. P. Sujan ◽  
V. Vijayasree ◽  
J. V. L. N. Seshagiri Rao

A reverse phase high performance liquid chromatographic method was developed for the simultaneous determination of simvastatin and ezetimibe in tablet dosage forms. The separation was effected on a C18 Supelcosil column (250 mm x 4.6 mm; 5µ) using a mobile phase consisting of 0.01 M ammonium acetate buffer and acetonitrile (35:65v/v) at a flow rate of 1 mL/min. The detection was made at 240 nm. The retention times for ezetimibe and simvastatin were 5.9 and 8.5 min respectively. Calibration curves were linear over the ranges of 0.5-40 µg/mL for simvastatin and 2.5-50 µg/mL for ezetimibe. The proposed method was validated as per the ICH and USP guidelines. The method is accurate and precise and found to be suitable for the quantitative analysis of both the drugs individually and in combination in tablet dosage forms.

2011 ◽  
Vol 8 (3) ◽  
pp. 1206-1211
Author(s):  
Madhukar A. Badgujar ◽  
Satish G. Pingale ◽  
Kiran V. Mangaonkar

A simple, precise and rapid isocratic reverse phase high performance liquid chromatographic method was developed for the simultaneous determination of paracetamol, chlorzoxazone and diclofenac sodium from tablet dosage form. The chromatographic separation was performed on an inertsil C18column (250 mm × 4.6 mm i.d 5 µm particle size). Mobile phase consisted of a mixture of phosphate buffer (0.02 M KH2PO4, pH adjusted to 3.7 using orthophosphoric acid), acetonitrile and methanol in the ratio of (25: 25: 50) at a flow rate of 1.0 mL/min. The wavelength was set at 220 nm. The proposed method was validated for linearity, accuracy, precision, LOD and LOQ. The calibration was linear over the range of 50-150 µg/mL for paracetamol, 50-150 µg/mL for chlorzoxazone and 5-15 µg/mL for diclofenac sodium. The retention times were found as 2.8 min for paracetamol, 4.2 min for chlorzoxazone and 6.4 min for diclofenac sodium. The method can be easily adopted for quality control analysis.


INDIAN DRUGS ◽  
2018 ◽  
Vol 55 (06) ◽  
pp. 63-68
Author(s):  
R. Raut ◽  
◽  
A. Patil ◽  
V. K Munipalli ◽  
M. Patel ◽  
...  

A simple precise and rapid Reverse Phase High Performance Liquid Chromatographic (RP-HPLC) method has been developed for quantitative determination of Regorafenib in tablet dosage form. In this method Hypersil Gold (C18, 150mm× 4.6mm id, 3μ) column with mobile phase consisting of Trifluoroacetic acid (0.2% v/v) and Acetonitrile in the ratio of (50: 50 v/v) at 400C in an isocratic mode was used. The detection was carried out at 260 nm and 20μL injection volume was selected with the flow rate 1mL/min. The linearity range of Regorafenib shows concentration between 5-200 μg/mL. The regression coefficient obtained was 0.999. Retention time of Regorafenib was found to be 6.49 minutes. Acetonitrile and Water in the ratio of (3:1) was used as a diluent. The method was validated as per ICH guidelines and is simple, fast, accurate, precise and can be applied for routine quality control analysis of Regorafenib in tablet dosage form.


2009 ◽  
Vol 92 (2) ◽  
pp. 404-409 ◽  
Author(s):  
Abdalla A Elshanawane ◽  
Samia M Mostafa ◽  
Mohamed S Elgawish

Abstract A high-performance liquid chromatographic method was developed for the simultaneous determination of 2 ternary mixtures containing amiloride hydrochloride, atenolol, hydrochlorothiazide, and chlorthalidone used in hypertension therapy. The use of cyanopropyl column results in satisfactory separation of both mixtures. The mobile phase consisted of 10 mM KH2PO4 buffer (pH 4.5) and methanol in a ratio of (75 25 v/v), at a flow rate of 1 mL/min. UV detector was operated at 275 nm. Calibration graphs were linear in the concentration ranges of 210, 20200, 10100, and 550 g/mL for amiloride hydrochloride, atenolol, hydrochlorothiazide, and chlorthalidone, respectively. Intraday and interday precision values (relative standard deviation) were <1.13 for mixture I (amiloride hydrochloride, atenolol, chlorthalidone), and <0.93 for mixture II (amiloride hydrochloride, atenolol, hydrochlorothiazide). The method was successfully applied for the determination of the 2 combinations in laboratory-prepared mixtures and commercial pharmaceutical formulation with high accuracy and precision. Statistical comparison of the results with those of the published methods showed excellent agreement and indicates no significant difference between them.