scholarly journals Semiautomatic Cochleostomy Target and Insertion Trajectory Planning for Minimally Invasive Cochlear Implantation

2014 ◽  
Vol 2014 ◽  
pp. 1-8 ◽  
Author(s):  
Wilhelm Wimmer ◽  
Frederic Venail ◽  
Tom Williamson ◽  
Mohamed Akkari ◽  
Nicolas Gerber ◽  
...  

A major component of minimally invasive cochlear implantation is atraumatic scala tympani (ST) placement of the electrode array. This work reports on a semiautomatic planning paradigm that uses anatomical landmarks and cochlear surface models for cochleostomy target and insertion trajectory computation. The method was validated in a human whole head cadaver model (n=10ears). Cochleostomy targets were generated from an automated script and used for consecutive planning of a direct cochlear access (DCA) drill trajectory from the mastoid surface to the inner ear. An image-guided robotic system was used to perform both, DCA and cochleostomy drilling. Nine of 10 implanted specimens showed complete ST placement. One case of scala vestibuli insertion occurred due to a registration/drilling error of 0.79 mm. The presented approach indicates that a safe cochleostomy target and insertion trajectory can be planned using conventional clinical imaging modalities, which lack sufficient resolution to identify the basilar membrane.

2018 ◽  
Vol 159 (41) ◽  
pp. 1680-1688 ◽  
Author(s):  
Roland Nagy ◽  
János András Jarabin ◽  
Balázs Dimák ◽  
Ádám Perényi ◽  
Ferenc Tóth ◽  
...  

Abstract: During the rehabilitation of hearing-impaired patients, the preservation of residual acoustic hearing following cochlear implantation by minimizing the implantation trauma allows for improved hearing performance. To achieve this, minimally invasive, soft surgery methods and thinner, atraumatic electrodes were required. In our present study, we reported a case where Cochlear® Nucleus CI532 Slim Modiolar electrode was implanted in a patient with residual hearing. Our aim was to study the possible preservation of postoperative acoustic residual hearing by audiological monitoring. Since childhood, due to her congenital hearing loss, she has been wearing a conventional, airborne hearing correction device on both ears. Six months before cochlear implantation, we measured the progression on both sides of the hearing loss, so we decided to perform cochlear implantation. The patient had residual hearing on both ears prior to surgery thus the Cochlear® Nucleus CI532 Slim Modiolar Implant was used. The minimally invasive surgery was performed on the patient’s right ear through the round window approach. Compared to the preoperative hearing threshold (average 85 dBHL) in the 4th postoperative week, an initial hearing threshold progression of 20–25 dBHL was observed between 0.25 and 1.0 kHz, while of 5–10 dBHL between 2.0–4.0 kHz. Hearing threshold measured in the 6th month showed a slight progression in the range above 1 kHz, but improved by the 12th month, to the results achieved at the 4th week. The effects of cochlear implantation on residual hearing have been studied in numerous studies, in which several key surgical and technical factors have been identified. Nucleus CI532 is a Slim Modiolar electrode profile that is close to the modiolus, so it is expected to have a lower endocochlear hydrodynamic load since it lies in the covering of the osseus spiral lamina, thus less influencing the dynamics of the basilar membrane. However, the perimodiolar location of the electrode array allows the adjacent nerve elements of the spiral ganglion to be stimulated with a lower electrical intensity and a reduced surface that may be neuroprotective. Preservation of acoustic residual hearing following cochlear implantation improves the patient’s speech perception and the sound localization skills, particularly in difficult circumstances. Long-term residual hearing preservation may also be of great importance in the subsequent feasibility for regenerative procedures and drug treatments. Orv Hetil. 2018; 159(41): 1680–1688.


2013 ◽  
Vol 149 (2_suppl) ◽  
pp. P119-P119
Author(s):  
Robert F. Labadie ◽  
Fitsum A. Reda ◽  
Jack H. Noble ◽  
Gregoire Blachon ◽  
Benoit M. Dawant ◽  
...  

2003 ◽  
Vol 117 (7) ◽  
pp. 527-531 ◽  
Author(s):  
Antje Aschendorff ◽  
Thomas Klenzner ◽  
Bernhard Richter ◽  
Ralf Kubalek ◽  
Heiner Nagursky ◽  
...  

The aim of the study presented was to assess the insertion mode and possible intracochlear trauma after implantation of the HiFocus® electrode with positioner in human temporal bones. The study was performed in five freshly frozen temporal bones. The position of electrodes was evaluated using conventional X-ray analysis, rotational tomography and histomorphological analysis. Insertion of the HiFocus® electrode with positioner resulted in considerable trauma to fine cochlear structures including fracture of the osseous spiral lamina, dislocation of the electrode array from the scala tympani into the scala vestibuli and fracture of the modiolus close to the cochleostomy. The implication of the results regarding clinical outcome will be discussed.


2014 ◽  
Vol 150 (4) ◽  
pp. 638-645 ◽  
Author(s):  
Pooyan Rohani ◽  
Jason Pile ◽  
Lueder A. Kahrs ◽  
Ramya Balachandran ◽  
Grégoire S. Blachon ◽  
...  

2015 ◽  
Vol 2015 ◽  
pp. 1-6 ◽  
Author(s):  
Philipp Mittmann ◽  
Grit Rademacher ◽  
Sven Mutze ◽  
Frederike Hassepass ◽  
Arneborg Ernst ◽  
...  

The position of the cochlear implant electrode array within the scala tympani is essential for an optimal postoperative hearing benefit. If the electrode array changes in between the scalae intracochlearly (i.e., from scala tympani to scala vestibuli), a reduced auditory performance can be assumed. We established a neural response telemetry-ratio (NRT-ratio) which corresponds with the scalar position of the electrodes but shows within its limits a variability. The aim of this study was to determine if insertion depth angle or cochlea size influences the NRT-ratio. The intraoperative electrophysiological NRT data of 26 patients were evaluated. Using a flat panel tomography system, the position of the electrode array was evaluated radiologically. The insertion depth angle of the electrode, the cochlea size, and the NRT-ratio were calculated postoperatively. The radiological results were compared with the intraoperatively obtained electrophysiological data (NRT-ratio) and statistically evaluated. In all patients the NRT-ratio, the insertion depth angle, and the cochlea size could be determined. A significant correlation between insertional depth, cochlear size, and the NRT-ratio was not found. The NRT-ratio is a reliable electrophysiological tool to determine the scalar position of a perimodiolar electrode array. The NRT-ratio can be applied independent from insertion depth and cochlear size.


2018 ◽  
Vol 39 (6) ◽  
pp. 700-706 ◽  
Author(s):  
Mathieu Trudel ◽  
Mathieu Côté ◽  
Daniel Philippon ◽  
David Simonyan ◽  
Noémie Villemure-Poliquin ◽  
...  

2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Robert F. Labadie ◽  
Katherine Riojas ◽  
Kathleen Von Wahlde ◽  
Jason Mitchell ◽  
Trevor Bruns ◽  
...  

ORL ◽  
2000 ◽  
Vol 62 (5) ◽  
pp. 251-256 ◽  
Author(s):  
Jan Kiefer ◽  
Alexander Weber ◽  
Thomas Pfennigdorff ◽  
Christoph von Ilberg

Sign in / Sign up

Export Citation Format

Share Document