scholarly journals Comparison of Endothelial Cell Loss following the Big Bubble versus the Microbubble Incision Technique during Deep Anterior Lamellar Keratoplasty in Eyes with Keratoconus

2020 ◽  
Vol 2020 ◽  
pp. 1-5
Author(s):  
Amro Abuelkheir ◽  
Mohamed Bahgat Goweida ◽  
Nada Medhat ◽  
Hany Ahmed Helaly

Introduction. Deep anterior lamellar keratoplasty (DALK) is now becoming an increasingly popular surgical technique in treating corneal stromal pathologies with healthy endothelium. Several advantages of DALK over penetrating keratoplasty (PKP) have been described such as maintenance of globe integrity, absence of endothelial rejection, and a low rate of chronic endothelial cell loss (ECL). ECL following PKP results in 50% cell loss after 2 years from the estimated graft endothelial cell density (ECD). Although there are several reports confirming that ECL following DALK is similar to the physiologic cell loss 2 years after surgery, few reports discussed the surgically induced ECL due to difficulty in preoperative imaging of ECD. Materials and Methods. This prospective, interventional study included 20 eyes of 20 patients, who underwent DALK surgery. 11 eyes underwent DALK using the big bubble technique, while 9 eyes underwent the microbubble technique. Postoperative evaluation was done 3 months after surgery and included best spectacle corrected visual acuity (BSCVA), keratometric readings, and refraction measured using an autokeratorefractometer (Topcon KR800, Japan) and endothelial cell density (ECD) using noncontact specular microscopy (Nidek CEM-530, Japan). Results. Regarding postoperative parameters such as postoperative logMAR visual acuity, postoperative mean K, and postoperative K max, there was no statistical difference found between both groups ( P = 0.754 , P = 0.119 , and P = 0.970 , respectively). Regarding change in specular endothelial cell density and percent change in the specular endothelial cell density, again there was no statistical difference between both groups with P = 0.057 and P = 0.126 , respectively (significance defined as P < 0.05 ). Conclusion. ECD is not affected by failure of the big bubble to form and continuing DALK via the microbubble technique.

2021 ◽  
Vol 10 (11) ◽  
pp. 2421
Author(s):  
Dominika Janiszewska-Bil ◽  
Barbara Czarnota-Nowakowska ◽  
Katarzyna Krysik ◽  
Anita Lyssek-Boroń ◽  
Dariusz Dobrowolski ◽  
...  

We compared the visual and refractive outcomes, intraocular pressure (IOP), endothelial cell loss (ECL), and adverse events in keratoconus patients after deep anterior lamellar keratoplasty (DALK) and penetrating keratoplasty (PK) with the best corrected visual acuity (BCVA) below 0.3 (logMAR 0.52). This is a prospective, comparative cohort study of 90 eyes (90 patients) with a clinical diagnosis of keratoconus. Patients underwent a complete eye examination before the surgical approach, 6 and 12 months postoperatively that consisted of BCVA, refractive astigmatism (AS), central corneal thickness (CCT), IOP, and ECL. Secondary outcomes were adverse events related to the surgical procedure. With lower ECL and less adverse events, DALK was revealed to be beneficial over PK with similar visual outcomes. Results: There was no significant difference between the BCVA in the DALK and PK groups (at 6 months: 0.49 ± 0.17 vs. 0.48 ± 0.17; p = 0.48; at 12 months: 0.54 ± 0.17 vs. 0.52 ± 0.14; p = 0.41). The mean value of AS was significantly lower after the PK procedure when compared to DALK, after both 6 and 12 months of follow up (p < 0.001). The CCT in the DALK group was significantly lower when compared to the PK group (at 6 months: 452.1 ± 89.1 µm vs. 528.9 ± 69.9 µm, p < 0.0001; at 12 months: 451.6 ± 83.5 µm vs. 525.5 ± 37.1 µm). The endothelial cell loss at 12 months after surgery was significantly lower after DALK when compared to PK (p < 0.0001). DALK transplantation should be considered as an alternative procedure in the surgical treatment of keratoconus.


2004 ◽  
Vol 137 (3) ◽  
pp. 397-400 ◽  
Author(s):  
Bart T.H. van Dooren ◽  
Paul G.H. Mulder ◽  
Carla P. Nieuwendaal ◽  
W.Houdijn Beekhuis ◽  
Gerrit R.J. Melles

2021 ◽  
pp. 112067212110143
Author(s):  
Enrica Sarnicola ◽  
Caterina Sarnicola ◽  
Albert Y Cheung ◽  
Vincenzo Sarnicola

Purpose: To report our surgical experience of deep anterior lamellar keratoplasty (DALK) performed in eyes with scarring resulting from a corneal penetrating wound without tissue loss. Methods: Case series of three eyes of three patients that underwent DALK for poor vision due to a scar resulting from a previous corneal penetrating wound. Surgery was performed at least 1 year after the initial injury. Manual dissection technique was used in all cases. Preoperative and postoperative best correct visual acuity (BCVA), postoperative residual bed thickness, and postoperative endothelial cell count (ECC) were evaluated. Results: Preoperative BCVA ranged from 1.3 to 1.0 LogMAR. Two eyes were pseudophakic and one eye had a traumatic cataract. Manual DALK was successfully accomplished in all three cases. The mean residual recipient bed thickness was 103 µm (range 68–130 µm). The mean endothelial cell loss at the 6th month of follow-up was 6% (range 3%–11%) with a further 1% decrease at 4 years. One of the patients underwent cataract surgery and limbal relaxing incisions 1 year after DALK having a total endothelial cell loss of 4.8% at 2 years of follow-up. BCVA at 2 years of follow-up was 0.1 LogMAR (range 0.22–0.0 LogMAR). No episode of rejection was recorded, and all grafts remained clear at last follow-up (5 years, range 4–6 years). Conclusions: Manual DALK should be considered in cases of corneal scars in optical zone resulting from penetrating wound.


2021 ◽  
pp. 112067212198963
Author(s):  
Martina Menchini ◽  
Francesco Sartini ◽  
Filippo Tatti ◽  
Enrico Peiretti ◽  
Michele Figus

Purpose: To report a case of fully dislocated XEN Gel Implant device into the anterior chamber, 18 months after its implantation and its impact on endothelial cell density. Result: A 75-year-old man with a history of multiple glaucoma surgeries during the last three years presented with an entirely dislocated XEN Gel implant into the anterior chamber. An endothelial cell density reduction was observed over 18 months. Thus, the implant was removed. In the short-term after surgery, the endothelial cell loss rate reduced. Conclusion: XEN Gel Implant can dislocate into the anterior chamber, increasing endothelial cell loss in an eye already underwent multiple surgical procedures with subsequent adverse events. Therefore, if the implant seems displaced, the endothelial cell density should be monitored, and the length of the free-tube segment within the anterior chamber should be measured, during the patient’s follow-up.


2020 ◽  
pp. bjophthalmol-2020-316653
Author(s):  
Cristina Bovone ◽  
Yoav Nahum ◽  
Vincenzo Scorcia ◽  
Giuseppe Giannaccare ◽  
Rossella Spena ◽  
...  

Background/aimsTo evaluate the clinical outcomes of deep anterior lamellar keratoplasty performed by stromal peeling in eyes that have previously undergone penetrating keratoplasty (PK) for keratoconus.MethodsStandardised stromal exchange included (1) 9 mm trephination of the recipient bed outside the old PK wound, (2) creation of a partial anterior corneal flap through lamellar dissection across the PK wound, (3) opening the stromal component of the old PK wound using blunt-tipped Vannas scissors until a plane of separation is reached, (4) severing the attachment of the PK surgical scar from the recipient host, (5) peeling the stroma of the PK graft from the underlying tissue and (6) suturing the donor anterior corneal lamella prepared by microkeratome dissection (450 µm depth, 9 mm diameter). Main outcome measures were success rate, best spectacle-corrected visual acuity (BSCVA) and endothelial cell loss (ECL).ResultsOf 21 post-PK eyes, stromal exchange succeeded in all but three cases, which were converted to a two-piece mushroom PK. After complete suture removal, mean BSCVA significantly improved from 0.95±0.39 logMAR preoperatively to 0.23±0.17 logMAR (p<0.001). Mean ECL was 5.4±23.2%. Double anterior chamber formation occurred in eight cases (44%), which all resolved after a single re-bubbling.ConclusionIn post-PK eyes, stromal exchange can be performed by means of simple peeling without deep anterior lamellar dissection of the previous PK graft. Large-diameter (9 mm) repeat keratoplasty through stromal peeling yields excellent visual outcomes and minimal ECL. Double anterior chamber formation may complicate the postoperative course, but prompt intervention allows successful management.


Sensors ◽  
2020 ◽  
Vol 20 (2) ◽  
pp. 428
Author(s):  
Shoujing Guo ◽  
Nicolas R. Sarfaraz ◽  
William G. Gensheimer ◽  
Axel Krieger ◽  
Jin U. Kang

Deep anterior lamellar keratoplasty (DALK) is a highly challenging procedure for cornea transplant that involves removing the corneal layers above Descemet’s membrane (DM). This is achieved by a “big bubble” technique where a needle is inserted into the stroma of the cornea down to DM and the injection of either air or liquid. DALK has important advantages over penetrating keratoplasty (PK) including lower rejection rate, less endothelial cell loss, and increased graft survival. In this paper, we successfully designed and evaluated the optical coherence tomography (OCT) distal sensor integrated needle for a precise big bubble technique. We successfully used this sensor for micro-control of a robotic DALK device termed AUTO-DALK for autonomous big bubble needle insertion. The OCT distal sensor was integrated inside a 25-gauge needle, which was used for pneumo-dissection. The AUTO-DALK device is built on a manual trephine platform which includes a vacuum ring to fix the device on the eye and add a needle driver at an angle of 60 degrees from vertical. During the test on five porcine eyes with a target depth of 90%, the measured insertion depth as a percentage of cornea thickness for the AUTO-DALK device was 90.05 % ± 2.33 % without any perforation compared to 79.16 % ± 5.68 % for unassisted free-hand insertion and 86.20 % ± 5.31 % for assisted free-hand insertion. The result showed a higher precision and consistency of the needle placement with AUTO-DALK, which could lead to better visual outcomes and fewer complications.


Sign in / Sign up

Export Citation Format

Share Document