scholarly journals Voltammetric Methods in Metallothionein Research

2005 ◽  
Vol 3 (1-2) ◽  
pp. 43-53 ◽  
Author(s):  
Ivana Šestáková ◽  
Tomáš Navrátil

The application of voltammetric methods using different rates of polarisation on HMDE reveal inert or labile behaviour of Cd- or Zn- complexes in the presence of excessive cadmium or zinc ions in solution. This phenomenon was demonstrated first on the simplest phytochelatin – complex of peptide(γ-Glu-Cys)2Glywith cadmium, later on rabbit liver metallothioneins –Cd7MTin the presence of cadmium andCd5Zn2MTin the presence of zinc. Voltammetric methods can distinguish between labile and inert complexes present simultaneously and therefore could elucidate their role in reactions of metal ion transfer.Another method using different rates of polarisation – elimination voltammetry with linear scan – proved that S-tetracoordinated complexes of Cd(II) or Zn(II) in the above-mentioned metallothioneins on HMDE are reduced in the adsorbed state. This implies the possibility of increasing the sensitivity of identification or determination of the above complexes. On carbon composite electrode, similar behaviour of Cd-complexes as on HMDE was observed using differential pulse voltammetry.

2012 ◽  
Vol 48 (4) ◽  
pp. 639-649 ◽  
Author(s):  
Kellen Heloizy Garcia Freitas ◽  
Orlando Fatibello-Filho ◽  
Ivanildo Luiz de Mattos

A carbon composite electrode modified with copper (II) phosphate immobilized in a polyester resin (Cu3(PO4)2-Poly) for the determination of rutin in pharmaceutical samples by square-wave voltammetry is described herein. The modified electrode allows the determination of rutin at a potential (0.20 V vs. Ag/AgCl (3.0 mol L-1 KCl)) lower than that observed at an unmodified electrode. The peak current was found to be linear to the rutin concentration in the range from 9.9 × 10-8 to 2.5 × 10-6 mol L-1, with a detection limit of 1.2×10-8 mol L-1. The response of the electrode was stable, with no variation in baseline levels within several hours of continuous operation. The surface morphology of the modified electrode was characterized by scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) system. The results obtained are precise and accurate. In addition, these results are in agreement with those obtained by the chromatographic method at a 95% confidence level.


2004 ◽  
Vol 16 (9) ◽  
pp. 769-773 ◽  
Author(s):  
Huey Fang Teh ◽  
Xinhao Yang ◽  
Haiqing Gong ◽  
Swee Ngin Tan

2016 ◽  
Vol 40 (1) ◽  
pp. 662-673 ◽  
Author(s):  
Nada F. Atta ◽  
Asmaa H. Ibrahim ◽  
Ahmed Galal

Ionic liquid crystals mimic the natural bio-based ionic liquid crystals such as cell membrane structures in their interactions with drugs.


2011 ◽  
Vol 54 (5) ◽  
pp. 1829-1835 ◽  
Author(s):  
J. F. Ping ◽  
J. Wu ◽  
Y. B. Ying ◽  
M. H. Wang ◽  
G. Liu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document