Influence of a Fibrothorax on the Flow/Volume Curve

Respiration ◽  
1988 ◽  
Vol 54 (3) ◽  
pp. 197-200 ◽  
Author(s):  
C.T. Bolliger ◽  
M.A. de Kock
1979 ◽  
Vol 46 (5) ◽  
pp. 867-871 ◽  
Author(s):  
A. Vinegar ◽  
E. E. Sinnett ◽  
D. E. Leith

Awake mice (22.6--32.6 g) were anesthetized intravenously during head-out body plethysmography. One minute after pentobarbital sodium anesthesia, tidal volume had fallen from 0.28 +/- 0.04 to 0.14 +/- 0.02 ml and frequency from 181 +/- 20 to 142 +/- 8. Functional residual capacity (FRC) decreased by 0.10 +/- 0.02 ml. Expiratory flow-volume curves were linear, highly repeatable, and submaximal over substantial portions of expiration in awake and anesthetized mice; and expiration was interrupted at substantial flows that abruptly fell to and crossed zero as inspiration interrupted relaxed expiration. FRC is maintained at a higher level in awake mice due to a higher tidal volume and frequency coupled with expiratory braking (persistent inspiratory muscle activity or increased glottal resistance). In anesthetized mice, the absence of braking, coupled with reductions in tidal volume and frequency and a prolonged expiratory period, leads to FRCs that approach relaxation volume (Vr). An equation in derived to express the difference between FRC and Vr in terms of the portion of tidal volume expired without braking, the slope of the linear portion of the expiratory flow-volume curve expressed as V/V, the time fraction of one respiratory cycle spent in unbraked expiration, and respiratory frequency.


2013 ◽  
Vol 58 (10) ◽  
pp. 1643-1648 ◽  
Author(s):  
M. Nozoe ◽  
K. Mase ◽  
S. Murakami ◽  
M. Okada ◽  
T. Ogino ◽  
...  

1990 ◽  
Vol 68 (6) ◽  
pp. 2550-2563 ◽  
Author(s):  
R. K. Lambert

A computational model for expiration from lungs with mechanical nonhomogeneities was used to investigate the effect of such nonhomogeneities on the distribution of expiratory flow and the development of alveolar pressure differences between regions. The nonhomogeneities used were a modest constriction of the peripheral airways and a 50% difference in compliance between regions. The model contains only two mechanically different regions but allows these to be as grossly distributed as left lung-right lung or to be distributed as a set of identical pairs of parallel nonhomogeneous regions with flows from each merging in a specified bronchial generation. The site of flow merging had no effect on the flow-volume curve but had a significant effect on the development of alveolar pressure differences (delta PA). With the peripheral constriction, greater values of delta PA developed when flows were merged peripherally rather than centrally. The opposite was true in the case of a compliance nonhomogeneity. The delta PA values were smaller at submaximal flows. Plots of delta PA vs. lung volume were similar to those obtained experimentally. These results were interpreted in terms of the expression used for the fluid mechanics of the merging flows. delta PA was greater when the viscosity of the expired gas was increased or when its density was reduced. Partial forced expirations were shown to indicate the presence of mechanical nonhomogeneity.


2011 ◽  
Vol 4 (3) ◽  
pp. 116-118 ◽  
Author(s):  
Juan Antonio Mazzei ◽  
Analía Barro ◽  
Mariano Egidio Mazzei ◽  
Tamara Portas ◽  
Hugo Esteva

1982 ◽  
Vol 29 (1) ◽  
pp. 30-36
Author(s):  
Song Hyun Nam ◽  
Hyun Ha Park ◽  
Re Hwe Kim ◽  
Sung Koo Han ◽  
Ye Won Kim ◽  
...  

2008 ◽  
pp. 91-97 ◽  
Author(s):  
G. A. Lyubimov ◽  
I. M. Skobeleva ◽  
G. M. Sakharova ◽  
A. V. Suvorov

This report introduces a mathematical model of forced expiration to analyze pulmonary function. Results of 3-year lung function monitoring of an ex-smoker have been shown in the paper. Actual values of lung volumes and airway resistance were used for modeling. The computerized data were compared to the flow-volume curve parameters and lung volumes measured during the forced expiration. Weak correlation between the "flow-volume" curve parameters and the time after quitting smoking together with significant change in the lung volumes and the airway resistance seen in the study could be due to some processes which have not been followed in this study (lung compliance, airway resistance at forced expiration, and elastic properties of airway walls).The results demonstrated that mathematical models could increase informative value of pulmonary functional tests. In addition, the model could emphasize additional functional tests for better diagnostic usefulness of functional investigations.


2017 ◽  
Vol 59 (5) ◽  
pp. 594
Author(s):  
Özlem Cavkaytar ◽  
Ayşe Büyükçam ◽  
Özlem Tekşam ◽  
Deniz Doğru-Ersöz ◽  
Zuhal Akçören ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document