24-Hour Contact Lens Sensor Monitoring of Intraocular Pressure-Related Profiles in Normal-Tension Glaucoma and Rates of Disease Progression

2017 ◽  
Vol 57 (4) ◽  
pp. 208-215 ◽  
Author(s):  
Katie Hoban ◽  
Robert Peden ◽  
Roly Megaw ◽  
Patricia Halpin ◽  
Andrew J. Tatham
2016 ◽  
Vol 2016 ◽  
pp. 1-8 ◽  
Author(s):  
Sarah C. Xu ◽  
Angela C. Gauthier ◽  
Ji Liu

Glaucoma is one of the leading causes of blindness worldwide. Recent studies suggest that intraocular pressure (IOP) fluctuations, peaks, and rhythm are important factors in disease advancement. Yet, current glaucoma management remains hinged on single IOP measurements during clinic hours. To overcome this limitation, 24-hour IOP monitoring devices have been employed and include self-tonometry, permanent IOP, and temporary IOP monitoring. This review discusses each IOP measuring strategy and focuses on the recently FDA-approved contact lens sensor (CLS). The CLS records IOP-related ocular patterns for 24 hours continuously. Using the CLS, IOP-related parameters have been found to be associated with the rate of visual field progression in primary open-angle glaucoma, disease progression in primary angle-closure glaucoma, and various clinical variables in ocular hypertension. The CLS has been used to quantify blink rate and limbal strain and measure the circadian rhythm in a variety of disease states including normal-tension glaucoma and thyroid eye disease. The effects of various IOP-lowering interventions were also characterized using the CLS. CLS provides a unique, safe, and well-tolerated way to study IOP-related patterns in a wide range of disease states. IOP-related patterns may help identify patients most at risk for disease progression and assist with the development of tailored treatments.


2018 ◽  
Vol 29 (5) ◽  
pp. 516-523 ◽  
Author(s):  
Naoki Tojo ◽  
Mitsuya Otsuka ◽  
Atsushi Hayashi

Purpose: Cataract surgeries have been shown to reduce intraocular pressure. We used a Sensimed Triggerfish® contact lens sensor to compare intraocular pressure levels and their fluctuation between before and after cataract surgeries in patients with normal-tension glaucoma. Methods: This was a prospective open-label study. Thirteen patients with normal-tension glaucoma were included. All patients underwent a 1-month washout and discontinued glaucoma medications during this study. In each eye, intraocular pressure fluctuations over 24 h were measured with the contact lens sensor before and at 3 months after the cataract surgery. We compared intraocular pressure levels and their fluctuation between before and after cataract surgeries. We used two approaches to evaluate the amplitude of intraocular pressure fluctuations: dual-harmonic regression analysis, and measurement of the difference between the maximum and the minimum value. Results: The mean pre-operative intraocular pressure was 14.7 ± 2.2 mm Hg and mean post-operative intraocular pressure was 11.4 ± 2.2 mm Hg. Cataract surgery significantly decreased intraocular pressure (p = 0.0005). In both methods, the post-operative fluctuations in intraocular pressure over 24 h were significantly smaller than their pre-operative counterparts (dual-harmonic regression analysis: p = 0.0171; difference between the maximum and the minimum: p = 0.0398). Conclusion: Cataract surgery decreased both intraocular pressure values and intraocular pressure fluctuations in normal-tension glaucoma patients.


2014 ◽  
Vol 93 (1) ◽  
pp. e14-e21 ◽  
Author(s):  
Luca Agnifili ◽  
Rodolfo Mastropasqua ◽  
Paolo Frezzotti ◽  
Vincenzo Fasanella ◽  
Ilaria Motolese ◽  
...  

2020 ◽  
Vol 68 (11) ◽  
pp. 2427
Author(s):  
Deepti Mittal ◽  
Suneeta Dubey ◽  
Saptarshi Mukherjee ◽  
Madhu Bhoot ◽  
YadunandanP Gupta

2017 ◽  
Vol 26 (3) ◽  
pp. 195-200 ◽  
Author(s):  
Naoki Tojo ◽  
Shinya Abe ◽  
Masaaki Ishida ◽  
Takaaki Yagou ◽  
Atsushi Hayashi

Author(s):  
Chien-Kai Tseng ◽  
Yu-Chieh Huang ◽  
Shang-Wei Tsai ◽  
Guan-Ting Yeh ◽  
Chung-Hao Chang ◽  
...  

Author(s):  
Ana Moya ◽  
Anton Guimerà ◽  
Irene Sánchez ◽  
Vladimir Laukin ◽  
Raúl Martín ◽  
...  

A new portable measuring device for monitoring intraocular pressure with a non invasive system using a prototype of contact lens has been developed. The contact lens is based on a new organic flexible highly piezo-resisitive film sensor that is glued to the central hole of a lens. The measuring system is wire connected to the contact lens and incorporates user interface methods and a Bluetooth link for bi-directional wireless data transfer. The key design aspects of such architecture are discussed in this paper. The system is designed with an architecture that can be integrated in the future in order to be placed in the contact lens. The discrete system is used to validate the electronic measurement operation and the contact lens sensor (CLS). The measurement instrument can calibrate the differences of the nominal value of the sensor and measure resistances variations that are related to pressure variations. The measuring system and the contact lens sensor were tested with an eye phantom and with enucleated pig eyes by applying pressure changes between 7 to 32 mmHg recording the electrical changes with the portable device.


2019 ◽  
Vol 207 ◽  
pp. 429
Author(s):  
Mandabi Sengupta ◽  
Chengchira A. Sangma ◽  
Mayuri Borgohain ◽  
Prafulla Sarma ◽  
Shahinur Tayab ◽  
...  