Single Motor Unit Activity of Human Intrinsic Laryngeal Muscles during Respiration

1992 ◽  
Vol 101 (10) ◽  
pp. 832-840 ◽  
Author(s):  
Cheryl M. Chanaud ◽  
Christy L. Ludlow

Individual motor units in the thyroarytenoid (TA) and cricothyroid (CT) muscles were studied in 10 normal human volunteers during quiet respiration. Both tonic and phasic firing patterns were found in both TA and CT units. The rate of firing was higher during inhalation than during exhalation in phasic TA units and in tonic CT units. Tonically active units had a higher firing frequency than phasically active units in both TA and CT muscles. Phasically active units corresponded with the respiratory cycle, with firing associated with inhalation in both the TA and CT muscles. A variety of firing patterns were found between units in both the TA and CT muscles, and in one subject, units recorded from the same muscle had very different firing patterns. The results suggest that although laryngeal motoneurons are modulated by the respiratory cycle, they do not respond uniformly to respiration.

2010 ◽  
Vol 108 (6) ◽  
pp. 1530-1541 ◽  
Author(s):  
Zoia C. Lateva ◽  
Kevin C. McGill ◽  
M. Elise Johanson

We studied the innervation and organization of motor units in the brachioradialis muscle of 25 normal human subjects. We recorded intramuscular EMG signals at points separated by 15 mm along the proximodistal muscle axis during moderate isometric contractions, identified from 27 to 61 (mean 39) individual motor units per subject using EMG decomposition, and estimated the locations of the endplates and distal muscle/tendon junctions from the motor-unit action potential (MUAP) propagation patterns and terminal standing waves. In three subjects all the motor units were innervated in a single endplate zone. In the other 22 subjects, the motor units were innervated in 3–6 (mean 4) distinct endplate zones separated by 15–55 mm along the proximodistal axis. One-third of the motor units had fibers innervated in more than one zone. The more distally innervated motor units had distinct terminal waves indicating tendonous termination, while the more proximal motor units lacked terminal waves, indicating intrafascicular termination. Analysis of blocked MUAP components revealed that 19% of the motor units had at least one doubly innervated fiber, i.e., a fiber innervated in two different endplate zones by two different motoneurons, and thus belonging to two different motor units. These results are consistent with the brachioradialis muscle having a series-fibered architecture consisting of multiple, overlapping bands of muscle fibers in most individuals and a simple parallel-fibered architecture in some individuals.


2007 ◽  
Vol 103 (5) ◽  
pp. 1706-1714 ◽  
Author(s):  
Keith N. Bishop ◽  
J. Ross McClung ◽  
Stephen J. Goldberg ◽  
Mary S. Shall

The ferret has become a popular model for physiological and neurodevelopmental research in the visual system. We believed it important, therefore, to study extraocular whole muscle as well as single motor unit physiology in the ferret. Using extracellular stimulation, 62 individual motor units in the ferret abducens nucleus were evaluated for their contractile characteristics. Of these motor units, 56 innervated the lateral rectus (LR) muscle alone, while 6 were split between the LR and retractor bulbi (RB) muscle slips. In addition to individual motor units, the whole LR muscle was evaluated for twitch, tetanic peak force, and fatigue. The abducens nucleus motor units showed a twitch contraction time of 15.4 ms, a mean twitch tension of 30.2 mg, and an average fusion frequency of 154 Hz. Single-unit fatigue index averaged 0.634. Whole muscle twitch contraction time was 16.7 ms with a mean twitch tension of 3.32 g. The average fatigue index of whole muscle was 0.408. The abducens nucleus was examined with horseradish peroxidase conjugated with the subunit B of cholera toxin histochemistry and found to contain an average of 183 motoneurons. Samples of LR were found to contain an average of 4,687 fibers, indicating an LR innervation ratio of 25.6:1. Compared with cat and squirrel monkeys, the ferret LR motor units contract more slowly yet more powerfully. The functional visual requirements of the ferret may explain these fundamental differences.


1988 ◽  
Vol 65 (1) ◽  
pp. 210-217 ◽  
Author(s):  
E. van Lunteren ◽  
N. S. Cherniack ◽  
T. E. Dick

To examine the effects of upper airway negative pressure (UAW NP) afferents on respiratory muscle activity during expiration (TE), diaphragm electromyograms (EMG) and triangularis sterni EMG and single motor unit activity were recorded from supine anesthetized tracheotomized cats while they breathed 100% O2. The period of TE during which the diaphragm was electrically active (TE-1) and the period of TE during which the diaphragm was quiescent (TE-2) were both increased with continuous UAW NP (P less than 0.001 and P less than 0.05, respectively), as was TE-1 as a percent of TE (P less than 0.001). Continuous UAW NP reduced peak triangularis sterni EMG (P less than 0.001) and delayed its expiratory onset (P less than 0.005) but did not alter its duration of firing. Changes in triangularis sterni EMG were due to a combination of complete cessation of motor unit activity (2 of 17 motor units), a reduction in mean motor unit firing frequency (P less than 0.02), and a delay in the expiratory onset of motor unit activity (P less than 0.001). Qualitatively similar results were obtained when UAW NP was applied during inspiration only. We conclude that 1) UAW NP has reciprocal stimulatory and inhibitory influences on diaphragm and triangularis sterni muscle electrical activity, respectively, during expiration, and 2) the reductions in triangularis sterni EMG are due to both motor unit derecruitment and a slowing of motor unit firing frequency.


1997 ◽  
Vol 78 (6) ◽  
pp. 3061-3068 ◽  
Author(s):  
Ole Kiehn ◽  
Torsten Eken

Kiehn, O. and T. Eken. Prolonged firing in motor units: evidence of plateau potentials in human motoneurons? J. Neurophysiol. 78: 3061–3068, 1997. Serotonin (5-HT) and norepinephrine-dependent plateau potentials are found in spinal motoneurons in reduced turtle and cat preparations. Triggering the plateau potential by short-lasting synaptic excitation causes a prolonged self-sustained firing, which can be terminated by short-lasting synaptic inhibition. The presence of plateau potentials can also allow neurons to fire in a bistable manner, i.e., shifting between stable low and high firing frequencies. Such a bistable firing behavior has been found in soleus motor units in unrestrained rats. In the present study single motor-unit activity was recorded from low-threshold units in human soleus and tibialis anterior muscles to evaluate whether a bistable firing behavior and/or prolonged firing could be evoked. Vibration of the homonymous muscle tendon (30–100 Hz, 2–10 s) was used as excitatory input to the motoneuron pool. Brief excitation while the muscle was electrically silent induced firing during the vibration and sometimes recruited units into prolonged stable firing outlasting the vibratory stimulus. However, a bistable firing behavior, i.e., vibration-induced maintained shifts between two stable levels of firing, could not be convincingly demonstrated. The reason for this was twofold. First, low-threshold human motor units tended to jump to a “preferred firing range” shortly after voluntary recruitment. This firing range was the same as when units were recruited from silence into prolonged firing by vibration. Below the preferred firing range, maintained firing was unstable and usually only possible when subjects were listening to the spike potentials or had visual force-feedback. Second, vibration when units were firing in the preferred firing range caused a transient increase in firing frequency but no maintained frequency shifts. Recordings from pairs of motor units showed that short-lasting vibration could recruit one unit into prolonged firing, while a second unit, which already fired in its preferred firing range, only transiently increased its firing rate during the vibration. This suggests that the prolonged firing was not the result of an increase in the common synaptic drive to the motoneuron pool. We conclude that a bistable firing behavior as seen in intact rats is probably absent in human low-threshold motor units, but that prolonged firing could be seen in response to short-lasting excitation. This latter phenomenon is compatible with the existence of plateau potentials, which have to have a threshold close to the threshold for sodium spike generation.


1998 ◽  
Vol 80 (1) ◽  
pp. 365-376 ◽  
Author(s):  
Torsten Eken

Eken, Torsten. Spontaneous electromyographic activity in adult rat soleus muscle. J. Neurophysiol. 80: 365–376, 1998. Single-motor-unit and gross electromyograms (EMG) were recorded from the soleus muscle in six unrestrained rats. The median firing frequencies of nine motor units were in the 16–25 Hz range, in agreement with previous studies. One additional motor unit had a median firing frequency of 47 Hz. This unit and one of the lower-frequency units regularly fired doublets. Motor-unit firing frequency was well correlated to whole-muscle EMG during locomotion. Integrated rectified gross EMG revealed periods of continuous modulation, phasic high-amplitude events, and tonic low-amplitude segments. The tonic segments typically were caused by a small number of motor units firing at stable high frequencies (20–30 Hz) for extended periods of time without detectable activity in other units. This long-lasting firing in single motor units typically was initiated by transient mass activity, which recruited many units. However, only one or a few units continued firing at a stable high frequency. The tonic firing terminated spontaneously or in conjunction with an episode of mass activity. Different units were active in different tonic segments. Thus there was an apparent dissociation between activity in different single motor units and consequently between single-motor-unit activity and whole-muscle EMG. It is proposed that the maintained tonic motor-unit activity is caused by intrinsic motoneuron properties in the form of depolarizing plateau potentials.


2010 ◽  
Vol 12 (S1) ◽  
Author(s):  
Cameron J Holloway ◽  
Lowri E Cochlin ◽  
Ion Codreanu ◽  
Edward Bloch ◽  
Marzieh Fatemianl ◽  
...  

2014 ◽  
Vol 112 (7) ◽  
pp. 1685-1691 ◽  
Author(s):  
Christopher J. Dakin ◽  
Brian H. Dalton ◽  
Billy L. Luu ◽  
Jean-Sébastien Blouin

Rectification of surface electromyographic (EMG) recordings prior to their correlation with other signals is a widely used form of preprocessing. Recently this practice has come into question, elevating the subject of EMG rectification to a topic of much debate. Proponents for rectifying suggest it accentuates the EMG spike timing information, whereas opponents indicate it is unnecessary and its nonlinear distortion of data is potentially destructive. Here we examine the necessity of rectification on the extraction of muscle responses, but for the first time using a known oscillatory input to the muscle in the form of electrical vestibular stimulation. Participants were exposed to sinusoidal vestibular stimuli while surface and intramuscular EMG were recorded from the left medial gastrocnemius. We compared the unrectified and rectified surface EMG to single motor units to determine which method best identified stimulus-EMG coherence and phase at the single-motor unit level. Surface EMG modulation at the stimulus frequency was obvious in the unrectified surface EMG. However, this modulation was not identified by the fast Fourier transform, and therefore stimulus coherence with the unrectified EMG signal failed to capture this covariance. Both the rectified surface EMG and single motor units displayed significant coherence over the entire stimulus bandwidth (1–20 Hz). Furthermore, the stimulus-phase relationship for the rectified EMG and motor units shared a moderate correlation ( r = 0.56). These data indicate that rectification of surface EMG is a necessary step to extract EMG envelope modulation due to motor unit entrainment to a known stimulus.


2018 ◽  
Vol 120 (4) ◽  
pp. 1525-1533
Author(s):  
Yue Zhang ◽  
Yuchio Yanagawa ◽  
Yasuhiko Saito

We previously reported that cholinergic current responses mediated via nicotinic acetylcholine (ACh) receptors (nAChRs) in the prepositus hypoglossi nucleus (PHN), which participates in gaze control, can be classified into distinct types based on different kinetics and are mainly composed of α7- and/or non-α7-subtypes: fast (F)-, slow (S)-, and fast and slow (FS)-type currents. In this study, to clarify how each current type is related to neuronal activities, we investigated the relationship between the current types and the membrane properties and the firing responses that were induced by each current type. The proportion of the current types differed in neurons that exhibited different afterhyperpolarization (AHP) profiles and firing patterns, suggesting that PHN neurons show a preference for specific current types dependent on the membrane properties. In response to ACh, F-type neurons showed either one action potential (AP) or multiple APs with a short firing duration, and S-type neurons showed multiple APs with a long firing duration. The firing frequency of F-type neurons was significantly higher than that of S-type and FS-type neurons. An α7-subtype-specific antagonist abolished the firing responses of F-type neurons and reduced the responses of FS-type neurons but had little effect on the responses of S-type neurons, which were reduced by a non-α7-subtype-specific antagonist. These results suggest that the different properties of the current types and the distinct expression of the nAChR subtypes in PHN neurons with different membrane properties produce unique firing responses via the activation of nAChRs. NEW & NOTEWORTHY Prepositus hypoglossi nucleus (PHN) neurons show distinct nicotinic acetylcholine receptor (nAChR)-mediated current responses. The proportion of the current types differed in the neurons that exhibited different afterhyperpolarization profiles and firing patterns. The nAChR-mediated currents with different kinetics induced firing responses of the neurons that were distinct in the firing frequency and duration. These results suggest that the different properties of the current types in PHN neurons with different membrane properties produce unique firing responses via the activation of nAChRs.


1991 ◽  
Vol 66 (6) ◽  
pp. 1838-1846 ◽  
Author(s):  
R. K. Powers ◽  
M. D. Binder

1. The tension produced by the combined stimulation of two to four single motor units of the cat tibialis posterior muscle was compared with the algebraic sum of the tensions produced by each individual motor unit. Comparisons were made under isometric conditions and during imposed changes in muscle length. 2. Under isometric conditions, the tension resulting from combined stimulation of units displayed marked nonlinear summation, as previously reported in other cat hindlimb muscles. On average, the measured tension was approximately 20% greater than the algebraic sum of the individual unit tensions. However, small trapezoidal movements imposed on the muscle during stimulation significantly reduced the degree of nonlinear summation both during and after the movement. This effect was seen with imposed movements as small as 50 microns. 3. The degree of nonlinear summation was not dependent on motor unit size or on stimulus frequency. The effect was also unrelated to tendon compliance because the degree of nonlinear summation of motor unit forces was unaffected by the inclusion of different amounts of the external tendon between the muscle and the force transducer. 4. Our results support previous suggestions that the force measured when individual motor units are stimulated under isometric conditions is reduced by friction between the active muscle fibers and adjacent passive fibers. These frictional effects are likely to originate in the connective tissue matrix connecting adjacent muscle fibers. However, because these effects are virtually eliminated by small movements, linear summation of motor unit tensions should occur at low force levels under nonisometric conditions.(ABSTRACT TRUNCATED AT 250 WORDS)


Sign in / Sign up

Export Citation Format

Share Document