Rapid and Sensitive Analysis of Trace Leads in Medicinal Herbs Using Laser-Induced Breakdown Spectroscopy–Laser-Induced Fluorescence (LIBS-LIF)

2019 ◽  
pp. 000370281985774 ◽  
Author(s):  
Yinhua Jiang ◽  
Juan Kang ◽  
Yarui Wang ◽  
Yuqi Chen ◽  
Runhua Li

Toxic metals in medicinal herbs are potentially harmful for people taking herbal medicines. In this work, laser-induced breakdown spectroscopy–laser-induced fluorescence (LIBS-LIF) spectroscopy was first applied to carry out rapid and sensitive trace lead analysis in medicinal herb samples. To overcome the problem of diversity on the sample size, shape, and density for different samples, original samples were pulverized to powder and then pressed into pellets for spectral analysis. A series of standard samples were self-made for building a calibration curve. As an exemplary study, lead in Rheum officinale was analyzed with LIBS-LIF spectroscopy with significantly improved analytical sensitivity. The R2 of the build linear calibration curve was 0.996 and the detection limit of lead in R. officinale was determined to be 0.13 ppm. The enhancement factor on the signal-to-background ratio was >100 under low lead concentrations if compared with LIBS analysis. The lead concentrations in several original R. officinale samples were quantitatively determined. This work demonstrated that LIBS-LIF can be successfully applied to carry out rapid, sensitive, and quantitative trace lead analysis for medicinal herbs.

2018 ◽  
Vol 33 (4) ◽  
pp. 658-662 ◽  
Author(s):  
M. Shen ◽  
C. M. Li ◽  
D. Na ◽  
Z. Q. Hao ◽  
X. Y. Li ◽  
...  

The enhanced spectral line of Y II 417.75 nm with an excitation laser working at 378.87 nm and its calibration curve.


2008 ◽  
Vol 80 (6) ◽  
pp. 1995-2000 ◽  
Author(s):  
Siu L. Lui ◽  
Yogesh Godwal ◽  
Michael T. Taschuk ◽  
Ying Y. Tsui ◽  
Robert Fedosejevs

2008 ◽  
Author(s):  
Christian Goueguel ◽  
Stéphane Laville ◽  
Hakim Loudyi ◽  
Mohamed Chaker ◽  
Mohamad Sabsabi ◽  
...  

2020 ◽  
Vol 35 (3) ◽  
pp. 626-631 ◽  
Author(s):  
Qingzhou Li ◽  
Wen Zhang ◽  
Zhiyang Tang ◽  
Ran Zhou ◽  
Jiujiang Yan ◽  
...  

LIBS-LIF technology is proposed to enhance the spectral intensity of uranium in ores and eliminate spectral interference to achieve the purpose of improving detection sensitivity.


2020 ◽  
Vol 12 (20) ◽  
pp. 2590-2598
Author(s):  
I. Rehan ◽  
K. Rehan ◽  
M. Z. Khan ◽  
S. Sultana ◽  
R. Muhammad ◽  
...  

Laser induced breakdown spectroscopy (LIBS) was applied to determine the elemental distribution of nutritional and trace heavy metals in pepper powders available in Pakistan using the standard calibration curve (CC)-LIBS technique.


Sign in / Sign up

Export Citation Format

Share Document