linear calibration
Recently Published Documents


TOTAL DOCUMENTS

523
(FIVE YEARS 151)

H-INDEX

33
(FIVE YEARS 4)

2022 ◽  
Author(s):  
Shomik Verma ◽  
Miguel Rivera ◽  
David O. Scanlon ◽  
Aron Walsh

Understanding the excited state properties of molecules provides insights into how they interact with light. These interactions can be exploited to design compounds for photochemical applications, including enhanced spectral conversion of light to increase the efficiency of photovoltaic cells. While chemical discovery is time- and resource-intensive experimentally, computational chemistry can be used to screen large-scale databases for molecules of interest in a procedure known as high-throughput virtual screening. The first step usually involves a high-speed but low-accuracy method to screen large numbers of molecules (potentially millions) so only the best candidates are evaluated with expensive methods. However, use of a coarse first-pass screening method can potentially result in high false positive or false negative rates. Therefore, this study uses machine learning to calibrate a high-throughput technique (xTB-sTDA) against a higher accuracy one (TD-DFT). Testing the calibration model shows a ~5-fold decrease in error in-domain and a ~3-fold decrease out-of-domain. The resulting mean absolute error of ~0.14 eV is in line with previous work in machine learning calibrations and out-performs previous work in linear calibration of xTB-sTDA. We then apply the calibration model to screen a 250k molecule database and map inaccuracies of xTB-sTDA in chemical space. We also show generalizability of the workflow by calibrating against a higher-level technique (CC2), yielding a similarly low error. Overall, this work demonstrates machine learning can be used to develop a both cheap and accurate method for large-scale excited state screening, enabling accelerated molecular discovery across a variety of disciplines.


Abstract A systematic DoE and Analytical Quality by Design (AQbD) approach was utilized for the development and validation of a novel stability indicating high-performance thin–layer chromatographic (HPTLC) method for Rivaroxaban (RBN) estimation in bulk and marketed formulation. A D-optimal design was used to screen the effect of solvents, volume of solvents, time from spotting to development and time for development to scanning. ANOVA results and Pareto chart revealed that toluene, methanol, water and saturation time had an impact on retention time. The critical method and material attributes were further screened by Box-Behnken design (BBD) to achieve optimal chromatographic condition. A stress degradation study was carried out and structure of major alkaline degradant was elaborated. According to the design space, a control strategy was used with toluene: methanol: water (6:2:2) and the saturation time was 15 min. A retention factor (RF) of 0.59 ± 0.05 was achieved for RBN using chromatographic plate precoated with silica gel at detection wavelength 282 nm with optimized conditions. The linear calibration curve was achieved in the concentration range of 200–1,200 ng/band with r 2 > 0.998 suggesting good coordination between analyte concentration and peak areas. The quadratic model was demonstrated as the best fit model and no interaction was noted between CMAs. The optimized HPTLC method was validated critically as stated in International Conference on Harmonization (ICH) Q2 (R1) guideline and implemented successfully for stress degradation study of RBN. The developed HPTLC method obtained through AQbD application was potentially able to resolve all degradants of RBN achieved through forced degradation study. The obtained results demonstrate that a scientific AQbD approach implementation in HPTLC method development and stress degradation study drastically minimizes the number of trials in experiments, ultimately time and cost of analysis could be minimized.


Author(s):  
DEWI PATMAYUNI ◽  
T. N. SAIFULLAH SULAIMAN ◽  
ABDUL KARIM ZULKARNAIN ◽  
SHAUM SHIYAN

Objective: This study aims to increase the solubility of simvastatin (SIM), a hydrophobic drug, by incorporating it into PCL-PEG-PCL triblock copolymer micelles and validating the assay method used, namely Uv-Vis spectrophotometric. Methods: The shake flask method was used to determine the increase in solubility experienced by SIM after being incorporated into the micellar system. The values ​​of maximum wavelength (λmax), linearity, LOD, LOQ, accuracy, and precision were used as parameters measured to assess the validity of the assay method used. Results: The results showed that PCL-PEG-PCL triblock copolymer micelles could increase SIM solubility by 9.7 times (89.49±5.75 µg/ml) compared to SIM without modification (9.19±0.24 µg/ml). The validation results show the λmax value of 239 nm, a linear calibration curve with an R-value of 0.9994, LOD and LOQ of 0.33 µg/ml and 1.00 µg/ml, accurate measurement with recovery at concentrations of 80%, 100%, and 120% were 102.93±1.32%, 100.78±0.40%, and 104.58±0.79% and also had good precision ​​with RSD<2%. Conclusion: The PCL-PEG-PCL triblock copolymer micelles can increase SIM solubility and the Uv-Vis spectrophotometric method has been validated successfully for the quantitative analysis of SIM in PCL-PEG-PCL triblock copolymer micelles.


2021 ◽  
Vol 12 (4) ◽  
pp. 469-481
Author(s):  
Muhammad Jamaluddin Ahmed ◽  
Muhammad Jihan Uddin ◽  
Muhammad Emdadul Hoque

A new spectrophotometric reagent, salicylaldehyde-orthoaminophenol (Sal-OAP) has been synthesized and characterized for the determination of selenium through novel reaction techniques. Also, a new highly selective, and sensitive spectrophotometric method for the nano-trace determination of selenium using salicylaldehyde-orthoaminophenol (Sal-OAP) has been developed. Sal-OAP undergoes reaction in a slightly acidic solution (0.0001-0.0002 M H2S04) with selenium (IV) to give an orange-red chelate, which has an absorption maximum at 379 nm. The reaction is instantaneous and absorbance remains stable for over 24 h. The average molar absorption co-efficient and Sandell’s sensitivity were found to be 6.4×105 L/mol.cm and 1.0 ng/cm2 of, respectively. Linear calibration graphs were obtained for 0.001-40.000 mg/Lof Se having detection limit of 0.1 µg/L and RSD 0-2 %. The stoichiometric composition of the chelate is 1:2 (Se:Sal-OAP). A large excess of over 60 cations, anions and some common complexing agents, such as chloride, azide, tartrate, EDTA, SCN¯etc., do not interfere in the determination. The developed method was successfully used in the determination of selenium in several Certified Reference Materials (Alloys, steels, human urine, bovine liver, drinking water, tea, milk, soil, and sediments) as well as in some environmental waters (Potable and polluted), biological fluids (Human blood, urine, hair, and milk), soil samples, food samples (Vegetables, rice, and wheat) and pharmaceutical samples (Tablet and syrup) and solutions containing both selenium (IV) and selenium (VI) as well as complex synthetic mixtures. The results of the proposed method for assessing biological, food and vegetables and soil samples were comparable with ICP-OES and AAS were found to be in excellent agreement. The method has high precision and accuracy (s = ±0.01 for 0.5 mg/L).


Biosensors ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 507
Author(s):  
Mukesh Thapa ◽  
Ryong Sung ◽  
Yun Seok Heo

Understanding the levels of glucose (G) and lactate (L) in blood can help us regulate various chronic health conditions such as obesity. In this paper, we introduced an enzyme-based electrochemical biosensor adopting glucose oxidase and lactate oxidase on two working screen-printed carbon electrodes (SPCEs) to sequentially determine glucose and lactate concentrations in a single drop (~30 µL) of whole blood. We developed a diet-induced obesity (DIO) mouse model for 28 weeks and monitored the changes in blood glucose and lactate levels. A linear calibration curve for glucose and lactate concentrations in ranges from 0.5 to 35 mM and 0.5 to 25 mM was obtained with R-values of 0.99 and 0.97, respectively. A drastic increase in blood glucose and a small but significant increase in blood lactate were seen only in prolonged obese cases. The ratio of lactate concentration to glucose concentration (L/G) was calculated as the mouse’s gained weight. The results demonstrated that an L/G value of 0.59 could be used as a criterion to differentiate between normal and obesity conditions. With L/G and weight gain, we constructed a diagnostic plot that could categorize normal and obese health conditions into four different zones. The proposed dual electrode biosensor for glucose and lactate in mouse whole blood showed good stability, selectivity, sensitivity, and efficiency. Thus, we believe that this dual electrode biosensor and the diagnostic plot could be used as a sensitive analytical tool for diagnosing glucose and lactate biomarkers in clinics and for monitoring obesity.


Sensors ◽  
2021 ◽  
Vol 21 (23) ◽  
pp. 7848
Author(s):  
Vitorino Biazi ◽  
Letícia Avellar ◽  
Anselmo Frizera ◽  
Arnaldo Leal-Junior

Shape reconstruction is growing as an important real-time monitoring strategy for applications that require rigorous control. Polymer optical fiber sensors (POF) have mechanical properties that allow the measurement of large curvatures, making them appropriate for shape sensing. They are also lightweight, compact and chemically stable, meaning they are easy to install and safer in risky environments. This paper presents a sensor system to detect angles in multiple planes using a POF-intensity-variation-based sensor and a procedure to detect the angular position in different planes. Simulations are performed to demonstrate the correlation between the sensor’s mechanical bending response and their optical response. Cyclic flexion experiments are performed at three test frequencies to obtain the sensitivities and the calibration curves of the sensor at different angular positions of the lateral section. A Fast Fourier Transform (FFT) analysis is tested as a method to estimate angular velocities using POF sensors. The experimental results show that the prototype had high repeatability since its sensitivity was similar using different test frequencies at the same lateral section position. The proposed approach proved itself feasible considering that all linear calibration curves presented a coefficient of determination (R2) higher than 0.9.


Molecules ◽  
2021 ◽  
Vol 26 (22) ◽  
pp. 6991
Author(s):  
Sooyoung Lee ◽  
Wang-Seob Shim ◽  
Heejo Yoo ◽  
Sanghee Choi ◽  
Jiyoung Yoon ◽  
...  

A sensitive and reproducible liquid chromatography-tandem mass spectrometry (LC-MS/MS) system was developed and fully validated for the simultaneous determination of ephedrine and pseudoephedrine in human plasma after oral administration of the herbal prescription Ojeok-san (OJS); 2-phenylethylamine was used as the internal standard (IS). Both compounds presented a linear calibration curve (r2 ≥ 0.99) over a concentration range of 0.2–50 ng/mL. The developed method was fully validated in terms of selectivity, lower limit of quantitation, precision, accuracy, recovery, matrix effect, and stability, according to the regulatory guidelines from the U.S. Food and Drug Administration and the Korea Ministry of Food and Drug Safety. This validated method was successfully applied for the pharmacokinetic assessment of ephedrine and pseudoephedrine in 20 healthy Korean volunteers administered OJS.


Materials ◽  
2021 ◽  
Vol 14 (21) ◽  
pp. 6700
Author(s):  
Ramaraj Sukanya ◽  
Karuppaiah Balamurugan ◽  
Shen-Ming Chen ◽  
Ramachandran Rajakumaran ◽  
K. Muthupandi ◽  
...  

In this study, we synthesized heterostructured zinc stannate/tin oxide microparticles (ZTO/TO MPs) by a simple coprecipitation method and used them as an effective electrode material for the electrochemical detection of the antibacterial drug secnidazole (SCZ). The as-prepared ZTO/TO MPs were characterized by XRD, Raman, FE-SEM, HR-TEM, EDX, and XPS analyses. The physiochemical studies clearly proved that the fabricated ZTO/TO MPs were formed in a heterostructure phase without other impurities. A glassy carbon electrode modified with the synthesized ZTO/TO MPs showed an excellent and improved electrocatalytic activity in the electrochemical reduction of SCZ. Using differential pulse voltammetry (DPV), an impressive linear calibration range, extending from 0.01 to 193 μM, was observed, coupled with a detection limit of 0.0054 μM and a sensitivity of 0.055 μA/μM. In addition, the ZTO/TO MPs/GCE showed very good selectivity for the detection of SCZ in the presence of a number of biological, inorganic, and structurally related compounds. Finally, the ZTO/TO MPs/GCE was investigated for the analysis of SCZ in human blood serum samples. A very good recovery was obtained when spiking the blood serum with SCZ, highlighting the good applicability of the ZTO/TO MPs/GCE for the electrochemical analysis of SCZ in complex biological samples.


Sign in / Sign up

Export Citation Format

Share Document