The Silicon Content of Body Fluids

1982 ◽  
Vol 27 (1) ◽  
pp. 17-19 ◽  
Author(s):  
J. W. Dobbie ◽  
Mary J. B. Smith

Samples of bile, pancreatic juice, cerebrospinal, pleural, peritoneal, synovial and amniotic fluid obtained from patients during routine clinical procedures were analysed for their silicon (Si) content by atomic absorption spectroscopy (AAS). Similar Si concentrations were found in each fluid, while these in turn were shown to be similar to the concentration of Si in the serum of 50 healthy subjects (mean serum Si 21.5 μmol/l, SD±4.5). The concentration of Si in 24-hour collections of urine from 50 healthy subjects was also determined (mean urinary Si 194 μmol/l, SD±94). A comparative study was made of serum Si levels in nine different species of domesticated animal.

2018 ◽  
Vol 28 (4) ◽  
pp. 1259-1264
Author(s):  
Kiril Lisichkov ◽  
Katerina Atkovska ◽  
Neven Trajchevski ◽  
Orce Popovski ◽  
Nadica Todorovska

The presence of some chemical compounds at higher levels than maximum permissible concentrations (MPC) in the drinking water, suggests of water resources pollution. In this paper the following elements were analyzed: total arsenic, cadmium, lead, cooper and zinc. Twelve samples of water from the water supply system from the city of Skopje were examined during one year from three different springs. Also, ten samples of bottled water from three producers from the Macedonian market were tested.The determined average mass concentrations of total As, Cd(II), Pb(II), Cu(II) and Zn(II) in the analyzed water samples from the water supply system are 1.35 μg/l, 0.06 μg/l, 0.6 μg/l, 0.9 μg/l and 1,12 μg/l, respectively, and for the tested bottled water, the mean values ranges from 0.56 - 0.83 μg total As / l, 0.053 - 0.056 μg Cd(II)/l, 0.51 - 0.54 μg Pb(II)/l , 0.6 - 0.87 μg Cu(II)/l and 0.68 - 0.8 μg Zn(II)/l water.The following instrumental analytical methods and techniques were used for the analysis of the tested samples of drinking water: flame atomic absorption spectroscopy (AAS), atomic absorption spectroscopy with hydride cеll, electrothermal atomic absorption spectroscopy.The obtained results are shown in tables and graphic form. According to the obtained results a comparative analysis was carried out indicate that it is a water of good quality that can be used in different branches of the process industry.The obtained results in this paper do not exceed the values of the MPC of the Republic of Macedonia prescribed by the legal regulations for the drinking water, which confirm the health safety of the drinking water from the water supply system in the city of Skopje and the packed waters from the Macedonian market in relation to the tested elements.


Sign in / Sign up

Export Citation Format

Share Document