Monitoring Adult Subglottic Stenosis With Spirometry and Dyspnea Index: A Novel Approach

2021 ◽  
pp. 019459982110608
Author(s):  
Eleftherios Ntouniadakis ◽  
Josefin Sundh ◽  
Mathias von Beckerath

Objective The aim was to examine the correlations among the anatomic Cotton-Myer classification, pulmonary function tests (PFTs), and patient-perceived dyspnea or dysphonia in patients with subglottic stenosis and identify measurements accurately reflecting treatment effects. Study Design Prospective cohort study. Setting Tertiary referral center. Method Fifty-two adults receiving endoscopic treatment for isolated subglottic stenosis were consecutively included. Correlations were calculated among the preoperative Cotton-Myer scale, PFTs, the Dyspnea Index (DI), and the Voice Handicap Index. Receiver operating characteristic curves were determined for PFT, DI, and Voice Handicap Index pre- and postoperative measurements. Results The Cotton-Myer classification correlated weakly with peak expiratory flow ( r = −0.35, P = .012), expiratory disproportion index ( r = 0.32, P = .022), peak inspiratory flow ( r = −0.32, P = .022), and total peak flow ( r = −0.36, P = .01). The DI showed an excellent area under the curve (0.99, P < .001), and among PFTs, the expiratory disproportion index demonstrated the best area under the curve (0.89, P < .001), followed by total peak flow (0.88, P < .001), peak expiratory flow (0.87, P < .001), and peak inspiratory flow (0.84, P < .001). Patients treated endoscopically with balloon dilatation showed a 53% decrease in expiratory disproportion index (95% CI, 41%-66%; P < .001) and a 37% improvement in peak expiratory flow (95% CI, 31%-43%; P < .001). Conclusion Expiratory disproportion index or peak expiratory flow combined with DI was a feasible measurement for the monitoring of adult subglottic stenosis. The percentage deterioration of peak expiratory flow and increase in expiratory disproportion index correlated significantly with a proportional percentage increase in DI.

2001 ◽  
Vol 95 (4) ◽  
pp. 908-912 ◽  
Author(s):  
Joseph D. Tobias ◽  
Joel O. Johnson ◽  
Kelly Sprague ◽  
Garry Johnson

Background With its introduction for widespread clinical use, there has been an increase in reports of bronchospasm related to the administration of rapacuronium. As it is commonly used for rapid sequence intubation, it has been suggested that these effects may be related to an inadequate depth of anesthesia. The current study examines the airway effects of rapacuronium in tracheally intubated, anesthetized adults. Methods Endotracheal intubation was accomplished without the use of neuromuscular blocking agents. Dynamic compliance, tidal volume, peak inspiratory flow rate, peak expiratory flow rate, and peak inflating pressure were measured after administration of either rapacuronium (1.5 mg/kg) or cis-atracurium (0.2 mg/kg) to 20 adult patients (10 received rapacuronium and 10 received cis-atracurium) anesthetized with propofol-remifentanil. Results Statistically significant increases in peak inflating pressure (22 +/- 6 to 28 +/- 9 cm H2O, P = 0.0012) and decreases in dynamic compliance (108 +/- 43 to 77 +/- 41 ml/cm H2O, P = 0.0001), peak inspiratory flow rate (0.43 +/- 0.11 to 0.39 +/- 0.09 l/s, P = 0.0062), peak expiratory flow rate (0.67 +/- 0.10 to 0.59 +/- 0.09 l/s, P = 0.0015), and tidal volume (744 +/- 152 to 647 +/- 135 ml, P = 0.0293) occurred after administration of rapacuronium. No changes were seen after administration of cis-atracurium. Conclusion These data demonstrate that rapacuronium, but not cis-atracurium, has significant airway effects in intubated, mechanically ventilated adults.


BMJ ◽  
1961 ◽  
Vol 1 (5236) ◽  
pp. 1365-1366 ◽  
Author(s):  
C. M. Tinker

1996 ◽  
Vol 9 (4) ◽  
pp. 828-833 ◽  
Author(s):  
O.F. Pedersen ◽  
T.R. Rasmussen ◽  
Ø. Omland ◽  
T. Sigsgaard ◽  
Ph.H. Quanjer ◽  
...  

2001 ◽  
Vol 51 (3) ◽  
pp. 248
Author(s):  
Chul Ho Oak ◽  
Kai Hag Sohn ◽  
Ki Ryong Park ◽  
Hyun Myung Cho ◽  
Tae Won Jang ◽  
...  

2014 ◽  
Vol 124 (6) ◽  
pp. 499-504 ◽  
Author(s):  
Kendall K. Tasche ◽  
Semirra Bayan ◽  
Nathan M. Schularick ◽  
Jeff Wilson ◽  
Henry T. Hoffman

Author(s):  
Shirley Coelho ◽  
Vicky Moore ◽  
Gareth Walters ◽  
Sherwood Burge

2016 ◽  
Vol 44 (6) ◽  
pp. 248
Author(s):  
Mardjanis Said ◽  
Sudigdo Sastroasmoro ◽  
Bambang Supriyatno ◽  
Yovita Ananta

Objective This study aims to compare peak expiratory flow mea-surement by peak flow meter and electronic spirometer in healthyelementary school children.Methods This was a cross-sectional study performed in an el-ementary school near Cipto Mangunkusumo hospital (SDNPegangsaan 01). The study group consisted of healthy childrenaged 6-12 year old. Data regarding identity and history of illnesswas taken in each subject. Routine physical examination was per-formed and recorded. Each subject performed lung function testsby means of electronic spirometer AS-7 as well as by Mini-Wrightpeak flow meter. The subject should perform a minimum of threemaneuvers for each method where only the best result was re-corded. Method comparison test to assess agreement betweentwo methods was employed in this study.Results There were 10 males and 15 females enrolled in this study.None of the subjects currently have any respiratory symptoms andsigns. This study found that the mean peak expiratory flow (PEF) byspirometer was 226.8±73.13 L/min while by peak flow meter was223.0±45.05. Mean difference between spirometer and peak flowmeter measurements is 6.2 with standard deviation of 60.82. Thesevalues resulted in limits of agreement of -115.44 to +127.84 L/min.Conclusions This study finds disagreement between electronicspirometer and Mini-Wright peak flow meter in measuring peakexpiratory flow, therefore these two devices cannot be usedinterchangeably. Mini-Wright peak flow meter still has a role inhome monitoring, but the physician should interpret the resultscarefully.


Sign in / Sign up

Export Citation Format

Share Document