Methods and clinical outcomes of in situ fenestration for aortic arch revascularization during thoracic endovascular aortic repair

Vascular ◽  
2020 ◽  
Vol 28 (4) ◽  
pp. 333-341 ◽  
Author(s):  
HL Li ◽  
YC Chan ◽  
HY Jia ◽  
SW Cheng

Objective Despite endovascular advances in fenestrated and branched devices, thoracic endovascular aortic repair (TEVAR) for arch pathologies remains challenging. The aim of this study was to provide a contemporary review on the current evidence for in situ fenestration during TEVAR and to evaluate its short- and mid-term clinical outcome in the management of arch pathology. Methods A systematic literature review on in situ fenestration of thoracic aortic stent-graft from January 2003 to September 2018 was performed under the instruction of Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) Statement. Results Our initial search yielded 169 studies, of which 21 articles were relevant to the topic and were finally included. One hundred and forty-five in situ fenestration procedures in 99 patients were reviewed, involving 25 innominate arteries (17%), 33 left common carotid arteries (23%) and 87 left subclavian arteries (60%). Twelve patients (12/99, 12%) had two-vessel fenestration and three-vessel fenestration was performed in 17 patients (17/99, 17%). Technical success was achieved in 136 arteries (136/145, 93%). Talent/Valiant with monofilament twill woven polyester fabric was the most common (50/99, 51%) stent-graft used for fenestration. Three methods reported for in situ fenestration were needle, laser and radiofrequency. Needle was the most frequently used device for fenestration, which was performed in 60 patients (60/99, 61%). Three patients (3/99, 3%) died with 30 days, none were in situ fenestration TEVAR procedure-related. Perioperative complications including one (1%) retrograde type A aortic dissection, two (2%) type II endoleaks, and three (3%) strokes were reported. The pooled estimate for overall technical success, perioperative mortality and stroke was 88.3% (95% CI, 78.6%–93.9%), 5.9% (95% CI, 2.5%–13.4%) and 9.5% (95% CI, 4.1%–20.6%), respectively. Four patients (4/96, 4%) died during follow-up, none were aortic-related. All the fenestration bridging stents were reportedly patent, with only 1 (1/96, 1%) asymptomatic left subclavian stent stenosis. Two patients (2/96, 2%) with type II endoleak from left subclavian artery required secondary intervention. Conclusion In situ fenestration appeared to be a feasible and effective method to extend proximal landing zone during TEVAR. It had an acceptable short-term result with high technical success and low fenestration related morbidity. Long-term durability data were lacking, and there was no high level evidence to recommend the routine use of in situ fenestration TEVAR for the management of arch pathology.

2018 ◽  
Vol 25 (4) ◽  
pp. 474-479 ◽  
Author(s):  
Lixin Wang ◽  
Xiushi Zhou ◽  
Daqiao Guo ◽  
Kai Hou ◽  
Zhenyu Shi ◽  
...  

Purpose: To describe a new adjustable puncture system for in situ fenestration in thoracic endovascular aortic repair (TEVAR). Technique: An adjustable puncture needle for use in conjunction with a steerable 8-F, 55-cm Fustar sheath is demonstrated in a 65-year-old man with acute complicated type B dissection involving the left subclavian artery (LSA). The puncture device features an inflatable balloon at the tip, a central lumen for 0.018-inch guidewires, and a 3-level puncture depth. After thoracic stent-graft deployment at zone 2, the needle/sheath combination was delivered from a left brachial artery access. The needle was adjusted perpendicular to the fabric of the stent-graft with the assistance of the steerable sheath. The balloon at the tip was inflated to center the needle, and the puncture depth was selected on the puncture needle system. Holding the sheath and puncture needle together, a hole was created in the graft fabric. The aperture was sequentially dilated to accommodate the mating stent selected to maintain perfusion to the LSA. This new device has been successfully applied in 6 patients treated with TEVAR for different arch pathologies. Conclusion: This new puncture device could assist in situ fenestration and improve the technical success rate.


Author(s):  
Lydia Hanna ◽  
Ammar Abdullah ◽  
Richard Gibbs ◽  
Michael Jenkins ◽  
Mohammad Hamady

Abstract Purpose To describe the dual purpose of left subclavian artery (LSA) scallop endografts to create the proximal landing zone (PLZ) and facilitate antegrade left-sided upper extremity access for branched endovascular aortic repair (BEVAR) of Type II thoracoabdominal aneurysms (TAAA) with a short PLZ. Technique Three patients with an inadequate (< 20 mm) PLZ underwent a 2-stage repair of Type II TAAA. Following femoral cut-down, a custom-made LSA scallop endograft was deployed into zone 2 to create the PLZ and maintain perfusion to the LSA. In a second procedure 36–96 days after insertion of the scalloped thoracic stent-graft, a branched abdominal stent-graft was subsequently deployed to dock into the proximal scallop endograft as the second stage. Via a left axillary conduit, a 12Fr sheath was used to cannulate the LSA scallop to facilitate selective catheterisation of antegrade branch cuffs and renovisceral target vessels, and insertion and deployment of bridging stents. The LSA scallop was also used to selectively catheterise and stent the perfusion branches via left-sided brachial puncture that were left open in each of the three cases 8–14 days after the second procedure to minimise the risk of spinal cord ischaemia. There were no neurological or endoleak complications. Conclusion LSA scallop endografts are a feasible and useful adjunct to create the PLZ and to provide antegrade access for visceral stenting of branches and target vessels through the LSA scallop in branched endovascular repair of Type II TAAA with short PLZ.


Author(s):  
Chi Ying Simon Chow ◽  
Yan Kit Ho ◽  
Takuya Fujikawa ◽  
Kevin Lim ◽  
Cheuk Man Chu ◽  
...  

Background and aim of the study The Valiant NavionTM stent graft system is a third-generation low profile thoracic endograft designed for thoracic endovascular aortic repair. In this population analysis, we report on the first Asian all-comers experience and outcomes who underwent thoracic endovascular aortic repair with the use of this new stent graft system. Methods Between May 2019 and October 2020, 21 patients with different aortic pathologies were prospectively recruited and retrospectively analyzed. Important clinical and device-related outcomes were evaluated. The endpoints included short-term survival, technical success, access failures, major vascular and clinical complications, endoleaks, and hospital stay. Results The commonest indication of stenting was penetrating aortic ulcers (28.6%) and 6 (28.6%) patients had emergency stenting performed for aortic transection or rupture. 30 days of survival post-procedure was recorded and complete. There were no major vascular complications. Deployment accuracy was 100%, and the technical success rate was 94.7% (18/19) with 1 patient having a type 2 endoleak on follow-up imaging. No neurological complications were noted. The mean operative time was 95 +/- 73.6 mins and the mean fluoroscopy time was 16.2 +/- 10.8 mins. Mean hospital stay for elective zone 2, 3 and 4 stenting was 5.3 +/- 3.8 days, and only 1 patient post zone 1 TEVAR required a brief (0.5 days) ICU stay. All procedures were performed via the percutaneous transfemoral route with 100% success in percutaneous closure. Conclusion This first reported Asian case series demonstrated versatility, safety, and efficacy of the Valiant NavionTM stent in Asian patients with different aortic pathologies


Vascular ◽  
2019 ◽  
Vol 27 (4) ◽  
pp. 369-377 ◽  
Author(s):  
Yonghui Qiao ◽  
Le Mao ◽  
Ying Ding ◽  
Jianren Fan ◽  
Kun Luo ◽  
...  

Objectives The left subclavian artery during thoracic endovascular aortic repair could be reconstructed by in situ fenestration. This study aims to evaluate the effects of thoracic endovascular aortic repair with in situ fenestration thoracic endovascular aortic repair on the hemodynamics. Methods A male patient suffering from aortic dissection is treated by in situ fenestration thoracic endovascular aortic repair and the fenestration stent implanted in the left subclavian artery is partially protruding in the aortic arch for the stability. Two-phase non-Newtonian blood model is applied and three-element Windkessel model is implemented to reproduce physiological pressure waves. Simulations are carried out in three postoperative models to analyze different in situ fenestration thoracic endovascular aortic repair strategies; Case A: the protrusion length of fenestration stent is 23.2 mm representing the clinical postthoracic endovascular aortic repair aorta; Case B: the protrusion length is reduced by half simulating the improved surgery; Case C: the protruding portion is removed to simulate the ideal fenestration. Results In Case A, a pressure difference is found on the fenestration stent surface and a blood acceleration phenomenon around the stent is observed. Only 2.36% of the inlet blood flow is assigned to the left subclavian artery. In the improved surgery, the blood supply to the left subclavian artery is elevated to 4.01%. As for the ideal fenestration, a further improvement is observed (6.14%). Moreover, the aortic arch surface exposed to low time-averaged wall shear stress expands significantly when the protrusion length is shortened. Conclusions Overall, we conclude that appropriately shortening the protrusion length of the stent-graft may improve the efficacy of in situ fenestration thoracic endovascular aortic repair from the perspective of hemodynamics.


2021 ◽  
pp. 152660282110612
Author(s):  
Ahmed Eleshra ◽  
Giuseppe Panuccio ◽  
Konstantinos Spanos ◽  
Fiona Rohlffs ◽  
Yskert von Kodolitsch ◽  
...  

Objectives The aim of this study is to report the safety and effectiveness of thoracic endovascular aortic repair (TEVAR) in a native proximal landing zone (PLZ) 2 for chronic type B aortic dissection (TBAD) patients with genetic aortic syndrome (GAS). Methods A retrospective review of a single center database to identify patients with GAS treated with TEVAR in native PLZ 2 for chronic TBAD and thoracic false lumen aneurysm between February 2012 and February 2018 was undertaken. Results In total, 31 patients with GAS (24 Marfan syndrome [MFS], 5 Loeys-Dietz syndrome [LDS], and 2 vascular Ehlers-Danlos syndrome [vEDS]) were treated by endovascular repair. Nineteen patients were treated by TEVAR as index procedures with 8 patients (5 females, mean age = 55, range = 36–79 years old) receiving TEVAR in native PLZ 2. Left subclavian artery (LSA) perfusion was preserved in all 8 patients: by left common carotid artery-LSA bypass in 6 patients, chimney stenting of the LSA in 1 patient, and partial coverage of LSA ostium in 1 patient. Technical success was achieved in all patients (100%). There was no 30 day mortality (0%). The 30 day morbidity (0%) was free from major complications. The median follow-up was 40 months (range = 7–79). One patient died due to non-aortic-related cause. Native PLZ 2 was free from complications in MFS patients (5/8). Two patients with LDS developed type Ia endoleak with aneurysmal progression. One patient was treated by proximal extension with a double inner branched arch stent-graft landing in the replaced ascending aorta. The other one was treated with frozen elephant trunk. Conclusion Thoracic endovascular aortic repair in native PLZ 2 was safe and effective with no early or midterm PLZ complications in patients with MFS with chronic TBAD in this limited series. Native PLZ 2 is not safe in patients with LDS and should only be used in emergencies as a bridging to open repair.


2019 ◽  
Vol 56 (3) ◽  
pp. 587-594 ◽  
Author(s):  
Huey-Shiuan Kuo ◽  
Jih-Hsin Huang ◽  
Jer-Shen Chen

Abstract OBJECTIVES This study aimed to evaluate the efficacy and safety of a handmade fenestrated stent graft over an aortic stent graft for preserving the left subclavian artery (LSA) in thoracic endovascular aortic repair (TEVAR). METHODS From July 2015 to October 2018, a total of 32 consecutive patients with various thoracic aortic pathologies who underwent TEVAR in which handmade fenestration over a thoracic aortic stent graft was used for LSA were included. Outcomes including technical success, procedure-related complications, perioperative mortality and morbidity and graft patency were analysed. RESULTS Twenty-four patients (75.00%) presented with aortic dissection, 5 patients (15.63%) with thoracic aortic aneurysm and 2 patients (6.25%) with penetrating aortic ulcer; 1 patient (3.13%) required re-TEVAR due to endoleak and sac expansion from previous TEVAR for thoraco-abdominal aneurysm. TEVAR was performed in a zone 2 landing with single fenestration for LSA (26 patients, 81.25%), zone 1 landing with double fenestration for both LSA and left common carotid artery (5 patients, 15.63%) or zone 1 landing with single fenestration for LSA and a chimney graft for left common carotid artery (1 patient, 3.13%). The technical success rate, defined as the successful alignment of fenestration to LSA, was 93.75%. At a mean follow-up of 17.3 months, 4 cases of endoleak and 2 cases of stent graft-induced new entry were noted, 3 of which were treated endovascularly. CONCLUSIONS Our preliminary results demonstrate the viability of preserving LSA blood flow in TEVAR using a handmade stent graft fenestration to treat various aortic pathologies in various clinical situations and the technical feasibility and short-term results that may justify the use of this method in emergency cases.


Sign in / Sign up

Export Citation Format

Share Document