Zenith AAA endovascular graft suprarenal bare metal stent separation with graft migration and type IA endoleak

Vascular ◽  
2021 ◽  
pp. 170853812110627
Author(s):  
Julian Smith ◽  
Simon Joseph ◽  
Catherine Thoo

Background The Zenith endovascular graft (Cook Medical, Bloomington, IN, USA) is a well-recognised device used in endovascular repair of abdominal aortic aneurysms (EVAR). After a small number of reported cases of suprarenal stent separation from the main body of the graft, modifications were made to the strength and durability of the suture line attachment of the proximal bare metal component prior to release in 2003. This report describes a further case of suprarenal stent separation and type IA endoleak in a patient who underwent an EVAR using the Zenith device in 2012. Methods We present a case report of a 77-year-old male with incidental finding of type IA endoleak on a background of elective endovascular repair for 50.4-mm infrarenal abdominal aortic aneurysm (AAA), with a Cook Zenith endograft. Computed tomography (CT) demonstrated separation of the suprarenal bare metal stent from the main body of the endograft, with resultant graft migration and increase in native aneurysm sac size. Results The patient underwent semi-urgent surgery with successful placement of a bridging thoracic stent graft between the lowest renal artery and main body of the pre-existing graft. Conclusions This case report describes a rare complication of Zenith devices, additionally emphasising the importance of regular surveillance imaging following EVAR.

2018 ◽  
Vol 5 (5) ◽  
pp. 12-17 ◽  
Author(s):  
M. A. Chernyavskiy ◽  
B. S. Artyushin ◽  
A. V. Chernov ◽  
Yu. A. Kudaev ◽  
D. V. Chernova ◽  
...  

This article demonstrates a case of effective and save endovascular treatment of distal aortic dissection and underlines its advantages over open surgery. The case describes successful implantation of bare metal stent into abdominal aorta. The patient of 78 years old underwent thoracic endovascular aortic repair as first stage, then bare metal stent implantation as second stage. There were no complications. CT-scan in 3 month showed no endoleaks or stent migration.


2014 ◽  
Vol 36 (1) ◽  
pp. 116-118
Author(s):  
Mustafa Adem Tatlısu ◽  
Serhan Özcan ◽  
Emre Aruğaslan ◽  
Ahmet Zengin ◽  
Mehmet Karaca ◽  
...  

2014 ◽  
Vol 36 (1) ◽  
pp. 116
Author(s):  
Mustafa Adem Tatlısu ◽  
Serhan Özcan ◽  
Emre Aruğaslan ◽  
Ahmet Zengin ◽  
Mehmet Karaca ◽  
...  

2008 ◽  
Vol 47 (4) ◽  
pp. 898
Author(s):  
John K. Bellos ◽  
Marios Moustardas ◽  
Christos D. Liapis

2011 ◽  
Vol 5 (1) ◽  
Author(s):  
Konstantinos M Lampropoulos ◽  
Themistoklis A Iliopoulos ◽  
Werner Budts

2007 ◽  
Vol 37 (5) ◽  
pp. 230 ◽  
Author(s):  
Yoon-Sung Cho ◽  
Hyun-Gwang Jung ◽  
Tae-Woo Kim ◽  
Kang-Min Kim ◽  
Jae-Hoon Chang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document