endovascular graft
Recently Published Documents


TOTAL DOCUMENTS

212
(FIVE YEARS 26)

H-INDEX

32
(FIVE YEARS 1)

Vascular ◽  
2021 ◽  
pp. 170853812110627
Author(s):  
Julian Smith ◽  
Simon Joseph ◽  
Catherine Thoo

Background The Zenith endovascular graft (Cook Medical, Bloomington, IN, USA) is a well-recognised device used in endovascular repair of abdominal aortic aneurysms (EVAR). After a small number of reported cases of suprarenal stent separation from the main body of the graft, modifications were made to the strength and durability of the suture line attachment of the proximal bare metal component prior to release in 2003. This report describes a further case of suprarenal stent separation and type IA endoleak in a patient who underwent an EVAR using the Zenith device in 2012. Methods We present a case report of a 77-year-old male with incidental finding of type IA endoleak on a background of elective endovascular repair for 50.4-mm infrarenal abdominal aortic aneurysm (AAA), with a Cook Zenith endograft. Computed tomography (CT) demonstrated separation of the suprarenal bare metal stent from the main body of the endograft, with resultant graft migration and increase in native aneurysm sac size. Results The patient underwent semi-urgent surgery with successful placement of a bridging thoracic stent graft between the lowest renal artery and main body of the pre-existing graft. Conclusions This case report describes a rare complication of Zenith devices, additionally emphasising the importance of regular surveillance imaging following EVAR.


Author(s):  
Michel Bosiers ◽  
Tilo Kölbel ◽  
Timothy Resch ◽  
Nikolaos Tsilimparis ◽  
Giovanni Torsello ◽  
...  

2020 ◽  
Vol 3 (1) ◽  
Author(s):  
Hiroki Nagayama ◽  
Tetsuhiro Otsuka ◽  
Atsushi Miyazaki ◽  
Shunsuke Taguchi ◽  
Seiji Matsukuma ◽  
...  

Abstract Background Open surgery can be required or even fatal if incomplete deployment of stent graft (SG) occurs. We herein report the first case in which a snare was successfully used to perform endovascular therapeutic troubleshooting on the proximal portion of a Zenith Alpha thoracic endovascular graft proximal component that showed incomplete deployment. Case presentation The patient was an 80-year-old woman. She underwent thoracic endovascular aortic repair (TEVAR) for subacute phase Stanford type B ulcer-like projection aortic dissection. Although the ulcer-like projection disappeared, a follow-up computed tomography angiogram (CTA) obtained approximately 1 year postoperatively showed type Ia and Ib endoleaks. Since there is a high risk of rupture as the aneurysm diameter increases, we determined that an additional SG was indicated. An attempt was made to place the SG in Zone 3, but as the lesser curvature side of the proximal portion stopped in a position that was perpendicular to the vascular wall (downward facing), the SG proximal portion did not completely expand. A guiding sheath was inserted into the aortic arch via the left brachial artery, and, using a snare that we inserted via the femoral artery, we grasped the guiding sheath. A catheter and guidewire (GW) were inserted via the guiding sheath and then rotated under the lesser curvature of the SG proximal portion; the GW was then passed through the loop of the snare. This allowed us to insert the hard loop structure under the SG proximal portion, which in turn allowed successful repair of the incomplete deployment of the SG. Type Ia and Ib endoleaks remained but were less than those before additional TEVAR. One week later, she was discharged. One year later, CT showed no interval change in the size of aortic aneurysm with dissection, and she has been followed on an outpatient basis. Conclusions When the endovascular diameter of the proximal aortic arch is large, incomplete deployment of the proximal portion of a Zenith Alpha thoracic endovascular graft can occur, but bailout is possible through the use of the snare technique as endovascular therapy.


Aorta ◽  
2020 ◽  
Vol 08 (05) ◽  
pp. 148-151
Author(s):  
Ana Lopez-Marco ◽  
Satya Das ◽  
Robert Serafino-Wani ◽  
Sadasivam Selvakumar ◽  
Benjamin Adams ◽  
...  

AbstractEndovascular graft infection is a rare but challenging complication that requires a tailored approach to remove the infected graft and restore the arterial circulation combined with long-term antibiotic therapy. We present a case surgically treated with explant of the graft and reconstruction of the thoracoabdominal aorta. Microbiological investigation revealed growth of Neisseria meningitidis, which is extremely rare in this location, and to our knowledge, has not been previously published in the literature.


Sign in / Sign up

Export Citation Format

Share Document