Assessment of glenoid baseplate initial micromotion and fixation strength in reverse total shoulder arthroplasty designs using a direct shear force methodology

2021 ◽  
pp. 175857322110329
Author(s):  
Therese E Parr ◽  
Jennifer K Anderson ◽  
Alan M. Marionneaux ◽  
John M Tokish ◽  
Stefan J Tolan ◽  
...  

Background In a reverse total shoulder arthroplasty, the altered glenohumeral joint center of rotation subjects the glenoid baseplate to increased shear forces and potential loosening. Methods This study examined glenoid baseplate micromotion and initial fixation strength with the application of direct shear force in a Sawbone model. The reverse total shoulder arthroplasty systems examined were the DJO Reverse® Shoulder Prosthesis, the Exactech Equinoxe® Reverse System, and the Tornier AequalisTM Reverse Shoulder Prosthesis. Specimens were cyclically tested with increasing shear loads until 150 µm of displacement between the implant and glenoid was achieved, and subsequently until failure, classified as either 1 cm of implant/glenoid displacement or fracture. Results The average load withstood for the 150 µm threshold for DJO, Tornier, and Exactech was 460 ± 88 N, 525 ± 100 N, and 585 ± 160 N, respectively. The average total load at device failure for DJO, Tornier, and Exactech was 980 ± 260 N, 1260 ± 120 N, and 1350 ± 230 N, respectively. Discussion The Exactech implant design trended toward requiring more load to induce micromotion at each threshold and to induce device failure, most commonly seen as inferior screw pull out. This study proposes design features that may enhance fixation and suggests little risk of initial micromotion or failure during initial post-operative recovery.

JBJS Reviews ◽  
2019 ◽  
Vol 7 (5) ◽  
pp. e7-e7 ◽  
Author(s):  
Jorge Rojas ◽  
Kyubo Choi ◽  
Jacob Joseph ◽  
Uma Srikumaran ◽  
Edward G. McFarland

Joints ◽  
2016 ◽  
Vol 04 (04) ◽  
pp. 236-246
Author(s):  
Stefano Petrillo ◽  
Umile Longo ◽  
Lawrence Gulotta ◽  
Alessandra Berton ◽  
Andreas Kontaxis ◽  
...  

Purpose:the past decade has seen a considerable increase in the use of research models to study reverse total shoulder arthroplasty (RTSA). Nevertheless, none of these models has been shown to completely reflect real in vivo conditions. Methods: we performed a systematic review of the literature matching the following key words: “reverse total shoulder arthroplasty” or “reverse total shoulder replacement” or “reverse total shoulder prosthesis” and “research models” or “biomechanical models” or “physical simulators” or “virtual simulators”. The following databases were screened: Medline, Google Scholar, EMBASE, CINAHIL and Ovid. We identified and included all articles reporting research models of any kind, such as physical or virtual simulators, in which RTSA and the glenohumeral joint were reproduced. Results: computer models and cadaveric models are the most commonly used, and they were shown to be reliable in simulating in vivo conditions. Bone substitute models have been used in a few studies.Mechanical testing machines provided useful information on stability factors in RTSA. Conclusions: because of the limitations of each individual model, additional research is required to develop a research model of RTSA that may reduce the limitations of those presently available, and increase the reproducibility of this technique in the clinical setting.


Sign in / Sign up

Export Citation Format

Share Document