scholarly journals A late presentation of pulmonary valve endocarditis following closure of patent ductus arteriosus in the childhood: A case report

2016 ◽  
Vol 2 ◽  
pp. 205555201667121
Author(s):  
Rajeev Trehan ◽  
Meena Trehan ◽  
Sharada Venkata Eshwarapragada
2020 ◽  
Vol 72 (1) ◽  
Author(s):  
Sanjeev H. Naganur ◽  
C. R. Pruthvi ◽  
Dinakar Bootla ◽  
Krishna Prasad ◽  
V. Krishna Santosh ◽  
...  

2012 ◽  
Vol 23 (2) ◽  
pp. 197-202 ◽  
Author(s):  
Mazeni Alwi ◽  
Rahmat R. Budi ◽  
Marhisham Che Mood ◽  
Ming C. Leong ◽  
Hasri Samion

AbstractObjectiveTo determine the feasibility and safety of the Conquest Pro wire as an alternative to radiofrequency wire for perforation of atretic pulmonary valve and subsequent balloon dilatation and patent ductus arteriosus stenting in patients with pulmonary atresia with intact ventricular septum.BackgroundRadiofrequency valvotomy and balloon dilatation has become the standard of care for pulmonary atresia with intact ventricular septum in many institutions today.MethodsWe report eight consecutive patients in whom we used the Conquest Pro coronary guidewire, a stiff wire normally reserved for revascularisation of coronary lesions with chronic total occlusion, for perforation of atretic pulmonary valve and subsequent balloon dilatation, and stenting of the patent ductus arteriosus.ResultsPerforation of atretic pulmonary valve was successful in seven out of eight cases. Radiofrequency valvotomy was employed after failure of perforation by the Conquest Pro wire in one case where the right ventricular outflow tract was broad based and tapered towards the pulmonary valve, and was heavily trabeculated. Failure of the Conquest Pro wire to perforate the pulmonary valve plate was mainly attributed by the failure to engage the wire at the correct position.ConclusionThe Conquest Pro wire for perforation and subsequent interventions in the more straightforward cases of pulmonary atresia with intact ventricular septum is effective and safe, simplifying the entire procedure. However, the radiofrequency generator and wires remain essential tools in the paediatric interventional catheter laboratory.


2012 ◽  
Vol 81 (1) ◽  
pp. 17-23
Author(s):  
M. Gozalo-Marcilla ◽  
C. J. Seymour ◽  
S. Schauvliege ◽  
T. Bosmans ◽  
F. Gasthuys

Patent ductus arteriosus (PDA) is one of the most common congenital vascular abnormalities in the dog. In veterinary medicine, surgical ligation (SL) and transarterial occlusion (TO) are two possible treatments that require general anesthesia. Two 4-month-old dogs were anesthetized for the correction of PDA, one by SL and the other by TO. Two different anesthetic and analgesic protocols were used, and were chosen to avoid potential complications. This case report describes two possible anesthetic approaches for PDA corrective surgery (SL and TO).


PEDIATRICS ◽  
1967 ◽  
Vol 39 (3) ◽  
pp. 446-448
Author(s):  
COLETTE M. KOHLER ◽  
DAN G. MCNAMARA

The presence of patent ductus arteriosus without a typical continuous murmur has long been recognized, especially in the presence of pulmonary hypertension, or a small ductus, or with associated cardiac defects; however, there are only a few reports of documented, intermittently disappearing murmurs occurring in individuals over 6 months of age with a substantial shunt in the absence of pulmonary hypertension or associated defects. Danilowicz, et al. have recently reported delayed closure of the ductus anteriosus up to 6 months of age in some premature infants. We present this case report of a 2½-year-old boy with patent ductus arteriosus with cardiac catheterizations during the disappearance and subsequent reappearance of a continuous murmur with documentation of absence of shunting when the murmur was absent and substantial shunting if the murmur was present.


Sign in / Sign up

Export Citation Format

Share Document