Applicability and Durability of Valve-Sparing Tetralogy of Fallot Repair

2021 ◽  
Vol 12 (5) ◽  
pp. 628-634
Author(s):  
Elizabeth H. Stephens ◽  
Brian L. Wolfe ◽  
Abhinav A. Talwar ◽  
Angira Patel ◽  
Joseph A. Camarda ◽  
...  

Background: Although valve-sparing repair remains ideal for patients with tetralogy of Fallot, the durability of valve-sparing repair and which patients may have been better served with a transannular patch remain unclear. Methods: Retrospective review was performed of tetralogy of Fallot operations at our institution from January 2008 to December 2018. Standard demographic data were collected, including echocardiographic parameters, operative details, and clinical outcomes. Statistical analysis was performed comparing the transannular patch and valve-sparing repair groups. Results: Sixty-seven patients underwent tetralogy of Fallot repair with a median age of 4.5 (3.2-6.0) months and weight of 5.8 (5.2, 6.7) kg. Seventeen (25%) patients underwent transannular patch repair and 50 (75%) patients underwent valve-sparing repair. There was no difference in age or weight between patients who underwent a transannular patch repair and those who underwent a valve-sparing repair. At last follow-up (median 42 months), there was a trend of a higher peak pulmonary valve/right ventricular outflow tract gradient ( P = .06) in the valve-sparing group, but no difference in the pulmonary valve annulus z-scores. Additionally, the pulmonary valve z-scores in the valve-sparing group decreased from −2.3 ± 1.0 on predischarge echocardiogram of to −1.2 ± 1.6 on last follow-up, with the peak gradient on predischarge 23 (0-37) mm Hg remaining stable on last follow-up at 18 (0-29) mm Hg. There was one reoperation: pulmonary valve replacement six years after a transannular patch. Conclusions: Obtaining a postrepair pulmonary valve z-score of −2 yields satisfactory, stable valve-sparing repair with pulmonary valve growth, acceptable gradients, minimal regurgitation, and high freedom from reintervention during follow-up.

Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Elizabeth H Stephens ◽  
Bryan L Wolfe ◽  
Abhinav A Talwar ◽  
Angira Patel ◽  
Joseph Camarda ◽  
...  

Introduction: While valve-sparing repair is ideal for Tetralogy of Fallot (TOF), it’s durability and which patients may benefit from a transannular patch remains unclear. To this end, we reviewed our experience with valve-sparing TOF repair. Methods: Retrospective review was performed of all primary TOF operations at our institution from 1/2008 to 12/2018. Standard demographic, operative, and echo data were collected, along with clinical outcomes. Transannular patch and valve-sparing repair groups were then compared. Results: Sixty-eight patients underwent TOF repair with a mean age of 4.1±2.2 months and weight of 5.7±1.8 kg. There was no difference in age or weight between patients who underwent a transannular patch repair and valve-sparing repair (Table). There was also no difference in the frequency of hypercyanotic spells or beta-blocker use. As expected the pre-operative pulmonary valve size and z-score were significantly different between groups. Bypass times were longer in the transannular patch group (176±40 vs. 144±40 minutes, p=0.005). There were no differences in post-operative complications. At last follow-up (median 41.5 months) there was a trend of a higher peak pulmonary valve gradient (p=0.07) in the valve-sparing group, but no difference in pulmonary valve annulus z-scores. Additionally, the pulmonary valve z-scores in the valve-sparing group decreased from -2.3±1.0 on pre-discharge echocardiogram to -1.2±1.6 on last follow-up, with the peak gradient on pre-discharge 20 (33) mmHg stable on last follow-up at 18 (29) mmHg and degree of pulmonary regurgitation stable. There was one reoperation in the cohort: a pulmonary valve replacement in a patient who had undergone a transannular patch repair 6 years prior. Conclusions: Valve-sparing TOF patients demonstrated stable repairs with pulmonary valve growth, acceptable gradients, minimal regurgitation, and high freedom from re-intervention during follow-up.


2017 ◽  
Vol 8 (2) ◽  
pp. 189-195
Author(s):  
Elizabeth H. Stephens ◽  
Jennifer Tingo ◽  
Marc Najjar ◽  
Betul Yilmaz ◽  
Stéphanie Levasseur ◽  
...  

Background: Repair of complete atrioventricular canal (CAVC) with tetralogy of Fallot (TOF) is a challenging operation increasingly being performed as a complete, primary repair in infancy. Previous studies have focused on perioperative outcomes; however, midterm valve function, ventricular function, and residual obstruction have received little attention. Methods: We retrospectively reviewed 20 patients who underwent CAVC/TOF repair (January 2005 to December 2014). A two-patch repair was used in all patients to correct the CAVC defect. Tetralogy of Fallot repair included transannular patch in 11 (65%) patients and valve-sparing in 6 (35%) patients. Results: The average age at surgery was 72 ± 122 weeks, 40% were male, and 80% had trisomy 21. Mean echo follow-up was 3.0 ± 3.0 years. There were no in-hospital or late mortalities. The rate of reoperation was 20%. At the latest follow-up, moderate left atrioventricular valve regurgitation was present in three (15%) patients and mild stenosis present in seven (35%) patients. One (5%) patient had moderate right ventricular outflow tract (RVOT) obstruction. The valve-sparing population was smaller at the time of surgery than the non-valve-sparing cohort (body surface area: 0.28 ± 0.04 vs 0.42 ± 0.11, P = .002) and less likely to have had a previous shunt (0% vs 64%, P = .01). Among the valve-sparing patients (six), at the latest follow-up, moderate pulmonary insufficiency was present in two (33%) patients. Conclusion: Repair of CAVC concomitant with TOF can be performed with low mortality and acceptable perioperative morbidity. Management of the RVOT remains a challenge for the long term.


2016 ◽  
Vol 43 (3) ◽  
pp. 207-213 ◽  
Author(s):  
Shantanu Pande ◽  
Jugal K. Sharma ◽  
C.R. Siddartha ◽  
Anubhav Bansal ◽  
Surendra K. Agarwal ◽  
...  

Tetralogy of Fallot often requires reconstruction of the right ventricular outflow tract with a transannular patch (TAP), but this renders the pulmonary valve incompetent and eventually leads to right ventricular dysfunction. We retrospectively evaluated the efficacy of a reconstructed pulmonary valve and annulus in 70 patients who underwent, from December 2006 through December 2010, complete correction of tetralogy of Fallot. We divided the 70 patients into 2 groups in accordance with whether they required (n=50) or did not require (n=20) a TAP. We used autologous untreated pericardium to fashion the TAP and to create both an annulus of the correct size and a competent pulmonary valve with native leaflets. We evaluated the efficiency of this procedure both functionally and anatomically. The median age of the patients was 11 years (range, 2–38 yr). There were 56 males, with no significant difference in sexual distribution between groups. The clinical follow-up was 88% for 57.5 months, and the echocardiographic follow-up was 80% for 36 months. There was no significant difference in outflow gradient or in the occurrence of pulmonary insufficiency between the TAP group (none, 31; mild, 12; moderate, 6; and severe, 1) and the No-TAP group (none, 16; moderate, 2; and severe, 2) (P=0.59). Nor was there any thickening or calcification in the constructed valves. We conclude that pulmonary valves constructed of untreated autologous pericardium performed as well as native valves after total tetralogy of Fallot correction at midterm.


Author(s):  
Oleg Fedevych ◽  
Ramana Dhannapuneni ◽  
Rafael Guerrero ◽  
Attilio Lotto

We present a surgical case of native pulmonary valve (PV) restoration in a 16-year-old boy with a previous history of transannular patch repair of tetralogy of Fallot in infancy. The PV was restored by approximation of split anterior commissure in the presence of developed and pliable leaflets well preserved after initial surgery. Postoperative echocardiogram showed a competent valve with peak velocity of 2.8 m/s. At six-week follow-up, the patient remained well, and echocardiogram demonstrated a competent PV with decreased velocity of 2.1 m/s across it. We encourage a mindful preservation of PV leaflets whenever it is possible at time of initial repair to implement this relatively easy operation to restore PV function later in life.


2017 ◽  
Vol 25 (6) ◽  
pp. 985-986 ◽  
Author(s):  
Khushboo N Parikh ◽  
Nishant C Shah ◽  
Joseph B Clark ◽  
John L Myers

1970 ◽  
Vol 6 (1) ◽  
pp. 48-50
Author(s):  
Md Mazibur Rahman

A 25 years male patient of Tetralogy of Fallot (TOF) with congenital absent of pulmonary valve (APV) presented with symptoms of palpitation and exertional respiratory distress without congestive heart failure. He underwent successful repair of intracardiac defects. The procedures consisted of patch closure of ventricular septal defect and right. ventricular outflow tract reconstruction with a monocusp transannular patch. Resection or plication of dilated pulmonary artery was not required. The patient is doing well without any symptoms. Key words: Tetralogy of Fallot; Absent pulmonary valve DOI: 10.3329/uhj.v6i1.7197University Heart Journal Vol.6(1) 2010 pp.48-50


Author(s):  
Ahmadali Amirghofran ◽  
Fatemeh Edraki ◽  
Mohammadreza Edraki ◽  
Gholamhossein Ajami ◽  
Hamid Amoozgar ◽  
...  

Abstract OBJECTIVES The prevention of pulmonary insufficiency (PI) is a crucial part of the tetralogy of Fallot repair. Many techniques have been introduced to construct valves from different materials for the right ventricular outflow tract, including the most commonly constructed monocusp valves. We are introducing a new bicuspid valve made intraoperatively using the autologous right atrial appendage (RAA) to prevent PI in these patients. METHODS The RAA valve was constructed and used in 21 patients with tetralogy of Fallot. The effective preservation of the native valve was impossible in all patients because of either a severe valve deformity or a small annulus. The RAA valve was created after ventricular septal defect closure and right ventricular outflow tract myectomy and was covered with a bovine transannular pericardial patch. The perioperative data were evaluated, and the echocardiography results were assessed immediately after operations and in follow-up with a median of 10.5 months. The data were retrospectively compared with 10 other patients with similar demographic data but with only transannular patches. RESULTS The mean age of the patients was 13.3 months. No mortality or related morbidity occurred after repair using the RAA valve. The PI severity early after the operation was trivial or no PI in 18 patients, and mild PI was observed in 3 patients, which progressed to moderate PI in one of them in the mean 12-month follow-up period. Fifteen patients had mild or no pulmonary stenosis, while moderate pulmonary stenosis was observed in 6 others. Compared with the other 10 patients with only transannular patches, the RAA valve patients had prolonged operative and clamping times, but no difference in postoperative course and shorter hospital stays. The degree of PI was, of course, significantly less in the RAA valve patients, but pulmonary stenosis was the same. CONCLUSIONS The RAA valve construction is a safe and effective technique to prevent PI after the tetralogy of Fallot repair, at least in terms of short- and mid-term results. A longer follow-up period is needed to confirm if this new valve can eliminate or significantly delay the need for pulmonary valve replacement in these patients.


Sign in / Sign up

Export Citation Format

Share Document