scholarly journals Biomechanical Comparison of 3 Syndesmosis Repair Techniques With Suture Button Implants

2018 ◽  
Vol 6 (10) ◽  
pp. 232596711880420 ◽  
Author(s):  
Andrew S. Parker ◽  
David P. Beason ◽  
Jonathan S. Slowik ◽  
Jefferson B. Sabatini ◽  
Norman E. Waldrop
2016 ◽  
Vol 38 (2) ◽  
pp. 200-207 ◽  
Author(s):  
Thomas O. Clanton ◽  
Scott R. Whitlow ◽  
Brady T. Williams ◽  
Daniel J. Liechti ◽  
Jonathon D. Backus ◽  
...  

Background: Significant debate exists regarding optimal repair for unstable syndesmosis injuries. Techniques range from screw fixation, suture-button fixation, or a combination of the two. In this study, 3 common repairs were compared using a simulated weightbearing protocol with internal and external rotation of the foot. Methods: Twenty-four lower leg specimens with mean age 54 years (range, 38-68 years) were used for testing. Following creation of a complete syndesmotic injury (AITFL, ITFL, PITFL, interosseous membrane), specimens were repaired using 1 of 3 randomly assigned techniques: (1) one 3.5-mm syndesmotic screw, (2) 1 suture-button construct, and (3) 2 divergent suture-button constructs. Repairs were cycled for 500 cycles between 7.5 Nm of internal/external rotation torque under a constant 750 N axial compressive load in a neutral dorsiflexion position. At 0, 10, 100, and 500 cycles, torsional cyclic loading was interrupted to assess torsional resistance to rotation within a physiologic range of motion (15 degrees external rotation to 10 degrees internal rotation). Torque (Nm), rotational position (degrees), and 3-dimensional data were collected throughout the testing to characterize relative spatial relationships of the tibiofibular articulation. Results: There were no significant differences between repair techniques in resistance to internal and external rotation with respect to the intact syndesmosis. Three-dimensional analysis revealed significant differences between repair techniques for sagittal fibular translation with external rotation of the foot. Screw fixation had the smallest magnitude of posterior sagittal translation (2.5 mm), and a single suture-button construct demonstrated the largest magnitude of posterior sagittal translation (4.6 mm). Screw fixation also allowed for significantly less anterior sagittal translation with internal rotation of the foot (0.1 mm) when compared to both 1 (2.7 mm) and 2 (2.9 mm) suture-button constructs. Conclusion: All repairs provided comparable rotational stability to the syndesmosis; however, no repair technique completely restored rotational stability and tibiofibular anatomic relationships of the preinjury state. Clinical Relevance: Constructs were comparable across most conditions; however, when repairing injuries with a suture-button construct, a single suture-button construct may not provide sufficient resistance to sagittal translation of the fibula.


2013 ◽  
Vol 99 (1) ◽  
pp. 66-71 ◽  
Author(s):  
R. Roberto ◽  
B. Dezfuli ◽  
C. Deuel ◽  
S. Curtiss ◽  
S. Hazelwood

2009 ◽  
Vol 155 (1) ◽  
pp. 82-88 ◽  
Author(s):  
Jen-Huei Chang ◽  
Hsain-Chung Shen ◽  
Guo-Shu Huang ◽  
Ru-Yu Pan ◽  
Chi-Fang Wu ◽  
...  

2016 ◽  
Vol 38 (2) ◽  
pp. 208-214 ◽  
Author(s):  
Jason M. Schon ◽  
Brady T. Williams ◽  
Melanie B. Venderley ◽  
Grant J. Dornan ◽  
Jonathon D. Backus ◽  
...  

Background: Historically, syndesmosis injuries have been repaired with screw fixation; however, some suggest that suture-button constructs may provide a more accurate anatomic and physiologic reduction. The purpose of this study was to compare changes in the volume of the syndesmotic space following screw or suture-button fixation using a preinjury and postoperative 3-D computed tomography (CT) model. The null hypothesis was that no difference would be observed among repair techniques. Methods: Twelve pairs of cadaveric specimens were dissected to identify the syndesmotic ligaments. Specimens were imaged with CT prior to the creation of a complete syndesmosis injury and were subsequently repaired using 1 of 3 randomly assigned techniques: (a) one 3.5-mm cortical screw, (b) 1 suture-button, and (c) 2 suture-buttons. Specimens were imaged postoperatively with CT. 3-D models of all scans and tibiofibular joint space volumes were calculated to assess restoration of the native syndesmosis. Analysis of variance and Tukey’s method were used to compare least squares mean differences from the intact syndesmosis among repair techniques. Results: For each of the 3 fixation methods, the total postoperative syndesmosis volume was significantly decreased relative to the intact state. The total mean decreases in volume compared with the intact state for the 1-suture-button construct, 2-suture-button construct, and syndesmotic screw were −561 mm3 (95% CI, −878 to −244), −964 mm3 (95% CI, −1281 to −647) and −377 mm3 (95% CI, −694 to −60), respectively. Conclusion: All repairs notably reduced the volume of the syndesmosis beyond the intact state. Fixation with 1 suture-button was not significantly different from screw or 2-suture-button fixation; however, fixation with 2 suture-buttons resulted in significantly decreased volume compared with screw fixation. Clinical Relevance: The results of this study suggest that the 1-suture-button repair technique and the screw fixation repair technique were comparable for reduction of syndesmosis injuries, although both may overcompress the syndesmosis.


2018 ◽  
Vol 39 (11) ◽  
pp. 1345-1354 ◽  
Author(s):  
Jessica E. Goetz ◽  
Nathan P. Davidson ◽  
M. James Rudert ◽  
Nicole Szabo ◽  
Matthew D. Karam ◽  
...  

Background: The purpose of this study was to compare mechanical behavior of conventional syndesmosis fixation devices with new anatomic repair techniques incorporating various repair augmentations to determine which approach would return rotational ankle mechanics closer to those of an intact ankle. Methods: Ten pairs of fresh-frozen through-the-knee cadaveric lower limbs were subjected to 7.5 Nm of external rotation torque while under 750 N of axial compression. After testing specimens intact and with the deltoid and syndesmotic ligament complexes completely destabilized, specimens underwent syndesmotic fixation using a screw, a suture button construct, a prototype structurally augmented flexible trans-syndesmotic fixation device, or the prototype device plus suture repairs of the anterior-inferior tibiofibular ligament and deep deltoid ligament. Syndesmotic repair devices were exchanged between tests so that each specimen was tested with 2 different fixation techniques. Whole-foot rotation angles at 7.5 Nm of applied torque were measured for comparison of the different repair strategies, and reflective markers mounted on the tibia, fibula, and talus were used to track translations and rotations of the talus and the fibula relative to the tibia during testing. Results: Syndesmotic destabilization significantly ( P < .001) increased whole-foot, talus, and fibula rotation in an axial plane and posterior fibula translation under 7.5 Nm of torque. Neither the suture button nor the augmented flexible trans-syndesmotic fixation device reduced those increases. Screw fixation or addition of anatomic ligament repairs to the augmented flexible fixation device successfully reduced axial plane rotations and sagittal plane translations to near intact levels. Conclusion: Flexible trans-syndesmotic fixation alone was found to be insufficient for restoring rotational stability to the ankle/talus or preventing sagittal plane displacement of the fibula. Clinical Relevance: Repairs to simulate anatomic structures disrupted during a syndesmosis injury were required to restore rotational stability to the foot when using flexible trans-syndesmotic fixation that may have clinical applicability.


2020 ◽  
Vol 29 (7) ◽  
pp. 1470-1478 ◽  
Author(s):  
Robert C. Williams ◽  
Randal P. Morris ◽  
Marc El Beaino ◽  
Nicholas H. Maassen