The serum-free light chain assay cannot replace 24-hour urine protein estimation in patients with plasma cell dyscrasias

Blood ◽  
2007 ◽  
Vol 109 (8) ◽  
pp. 3611-3612 ◽  
Author(s):  
Seema Singhal ◽  
Regina Stein ◽  
Eric Vickrey ◽  
Jayesh Mehta
2019 ◽  
Vol 23 (6) ◽  
pp. 763-772
Author(s):  
Olga Kukuy ◽  
Batia Kaplan ◽  
Sizilia Golderman ◽  
Alexander Volkov ◽  
Adrian Duek ◽  
...  

Author(s):  
Joannes F.M. Jacobs ◽  
Jillian R. Tate ◽  
Giampaolo Merlini

AbstractThe serum free light chain (FLC) assay has proven to be an important complementary test in the management of patients with monoclonal gammopathies. The serum FLC assay has value for patients with plasma cell disorders in the context of screening and diagnosis, prognostic stratification, and quantitative monitoring. Nonetheless, serum FLC measurements have analytical limitations which give rise to differences in FLC reporting depending on which FLC assay and analytical platform is used. As the FLC measurements are incorporated in the International Myeloma Working Group guidelines for the evaluation and management of plasma cell dyscrasias, this may directly affect clinical decisions. As new certified methods for serum FLC assays emerge, the need to harmonise patient FLC results becomes increasingly important. In this opinion paper we provide an overview of the current lack of accuracy and harmonisation in serum FLC measurements. The clinical consequence of non-harmonized FLC measurements is that an individual patient may or may not meet certain diagnostic, prognostic, or response criteria, depending on which FLC assay and platform is used. We further discuss whether standardisation of serum FLC measurements is feasible and provide an overview of the steps needed to be taken towards harmonisation of FLC measurements.


Blood ◽  
2015 ◽  
Vol 126 (23) ◽  
pp. 2956-2956
Author(s):  
Tatiana Prokaeva ◽  
Brian Spencer ◽  
Fangui Sun ◽  
Nathaniel McConnell ◽  
Richard M O'hara ◽  
...  

Abstract Background: Serum and urine immunofixation electrophoreses (SIFE/UIFE) are routinely used for detection of clonal immunoglobulins (Ig) in AL amyloidosis. Serum free light chain (FLC) assays (Freelite®, The Binding Site Ltd., Birmingham, UK) have significantly improved the management of patients with AL amyloidosis by providing quantitative measure for the detection and monitoring of clonal plasma cell disease. However, up to 20% of patients with AL amyloidosis may have uninformative serum free light chain values. Objective: To assess the quantitative potential of serum Heavy/Light Chain (HLC) pairs (Hevylite®, The Binding Site Ltd., Birmingham, UK) assay in identification of clonal plasma cell disease in AL amyloidosis. Methods: One hundred and ninety-nine untreated patients with AL amyloidosis were included in this study. Patients with multiple myeloma or B cell lymphoproliferative diseases associated AL amyloidosis were excluded. Serum sampleswere obtained at initial evaluation and stored at -20°C. SIFE/UIFE were performed at the time of sample collection. HLC pairs were assessed by the Hevylite® assay. HLC κ/λ normal ratios (HLCR) were: 1.12-3.21 for IgG κ/λ; 0.78-1.94 for IgA κ/λ; and 1.18-2.74 for IgM κ/λ. FLCs were assessed by the Freelite® assay; FLC κ/λ normal ratio (FLCR) was 0.26-1.65. In 103 cases, FLC testing was performed at the time of sample collection; 96 cases were tested at The Binding Site. Vital status of patients was obtained from either medical records or Social Security Death Index. Follow-up ended in June 2014. Results: An abnormal HLCR was found in 74 (37.2%), an abnormal FLCR in 163 (81.9%), and SIFE/UIFE positivity in 187 (94%) of 199 patients with AL amyloidosis. Of 36 patients with a normal FLCR, 23 (63.9%) were noted with an abnormal HLCR compared to 51 (31.3%) patients in an abnormal FLCR group (P = 0.001). In total 186/199 (93.5%) patients with AL amyloidosis had abnormalities in either HLCR or FLCR, compared to 187/199 (94%) of patients who were SIFE/UIFE+ (Table 1). The combined use of both FLCR and HLCR yielded quantifiable information in 93.5% of cases; the use of both tests in combination with SIFE/UIFE identified plasma cell clonality in 100% of patients. Seventy-two cases presented with an abnormal HLCR for a single isotype and 2 in multiple Ig isotypes. In all cases, involved LC type of abnormal HLCR matched LC type identified by SIFE/UIFE. None of 12 cases that were negative on the SIFE/UIFE presented with an abnormal HLCR, however, all showed abnormalities in FLCR. Table 1. Comparative efficiency of FLCR, HLCR and Serum/Urine Immunofixation in AL Amyloidosis patients. SIFE/UIFE+ (n=187) SIFE/UIFE- (n=12) HLCR+/FLCR+ 51 (27.2%) - HLCR+/FLCR- 23 (12.3%) - HLCR-/FLCR+ 100 (53.5%) 12 (100%) HLCR-/FLCR- 13 (7%) - Overall survival was similar in patients with and without abnormal HLCR (Log rank p=0.092; Figure 1), whereas patients with an abnormal FLCR had a significantly inferior overall survival compared to those with a normal FLCR (Log rank p=0.027; Figure 2). Combined use of both HLCR and FLCR demonstrated a trend toward superior overall survival in a group of patients with an abnormal HLCR / normal FLCR (Wilcoxon p=0.037; Log rank p=0.107; Figure 3). Conclusions: The Hevylite® assay provided information in addition to other laboratory tests for clonal plasma cell disease in AL amyloidosis. The combined use of the HLCR and FLCR provided quantifiable information in 93.5% of patients. The use of both assays in combination with SIFE/UIFE detected clonal disease in all patients. HLCR has potential to quantify clonal disease in patients with uninformative FLCR results. An abnormal HLCR was not predictive of overall survival, while an abnormal FLCR was, in this series of patients. Combined use of HLCR and FLCR could be beneficial in prognostication of outcome in AL amyloidosis. Disclosures McConnell: The Binding SIte: Employment. O'hara:The Binding Site: Employment.


Blood ◽  
2005 ◽  
Vol 106 (11) ◽  
pp. 2563-2563
Author(s):  
David E. Smith ◽  
Jude Abadie ◽  
Daniel Bankson ◽  
Graham Mead

Abstract Introduction and Methods: The purpose of this study was to evaluate the serum free light chain (FLC) assay in its ability to improve performance of protocols designed to screen for plasma cell disorders. We measured M-protein levels using serum protein electrophoresis (SPEP) in 312 consecutive patients being screened for plasma cell disorders at the Veterans Administration Medical Center - Puget Sound. The serum kappa and lambda free light chain levels were quantitated using the serum FLC assay in these same patients. The kappa/lambda ratio was calculated using the free kappa and free lambda results from the serum FLC assay. Results: SPEP results indicated the presence of a possible monoclonal gammopathy in 77 of the 312 patients in this study. In this group of 77 patients, a plasma cell disorder was diagnosed in 27 of them. The serum FLC assay showed an abnormal kappa/lambda ratio in 20 of these 77 patients, all 20 of whom were diagnosed with multiple myeloma. In the group of 235 patients with normal SPEP results, 17 were found to have an abnormal kappa/lambda ratio. Of these 17 patients, 15 were diagnosed with multiple myeloma, one with lymphoma, and one with bladder cancer. Conclusions: Because a number of disorders and diseases can increase production of immunoglobulins, there were a significant number of false positives in the SPEP results. At the same time, there were also several false negative SPEP results. The number of both false positives and false negatives was smaller for the serum FLC assay. Further, use of SPEP and the serum FLC assay together resulted in significantly improved sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). (See Table 1.) These results indicate an important role for the serum FLC assay in screening for monoclonal gammopathies. Table 1. Performance of SPEP, sFLC, and both assays in screening for plasma cell disorders SPEP Alone sFLC Alone Both SPEP and sFLC Sensitivity 64% 88% 100% Specificity 81% 98% 99% Positive Predictive Value 35% 88% 89% Negative Predictive Value 94% 98% 100%


Blood ◽  
2006 ◽  
Vol 108 (11) ◽  
pp. 5011-5011
Author(s):  
Jerry A. Katzmann ◽  
Angela Dispenzieri ◽  
Robert Kyle ◽  
Melissa R. Snyder ◽  
Mathew F. Plevak ◽  
...  

Abstract Due to the diagnostic sensitivity of serum free light chain quantitation for monoclonal light chain diseases, it has been suggested that urine assays no longer need be performed as part of the diagnostic algorithm for monoclonal proteins. We reviewed our experience to determine the relative diagnostic contribution of urine assays. Methods: Patients with a monoclonal gammopathy and monoclonal urinary protein at initial diagnosis who also had a serum immunofixation and serum free light chain quantitation within 30 days of diagnosis were identified (n = 428). The laboratory results for serum protein electrophoresis, serum immunofixation, serum free light chain, urine protein electrophoresis, and urine immunofixation were reviewed. Results: The patients in this cohort had diagnoses of multiple myeloma, primary amyloid, monoclonal gammopathy of undetermined significance, smoldering multiple myeloma, solitary plasmacytomas, and other less frequently detected monoclonal gammopathies. By definition of the cohort, all 428 had a monoclonal urine protein. 86% had an abnormal serum free light chain K/L ratio, 81% had an abnormal serum protein electrophoresis, and 94% had an abnormal serum immunofixation. In only 2 patients, however, were all 3 serum assays normal. Both of these were patients with monoclonal gammopathy of undetermined significance (idiopathic Bence Jones proteinuria). Conclusion: Discontinuation of urine studies and reliance on a diagnostic algorithm using solely serum studies (protein electrophoresis, immunofixation, and free light chain quantitation), missed 2 of the 428 monoclonal gammopathies (0.5 %) with urinary monoclonal proteins, and these 2 cases required no medical intervention.


Sign in / Sign up

Export Citation Format

Share Document