scholarly journals 211 MRI of coronary vessel wall injury in a swine model of coronary intervention using an eletrostatically stabilized VSOP nanoparticle

2008 ◽  
Vol 10 (Suppl 1) ◽  
pp. A72 ◽  
Author(s):  
Christian von Bary ◽  
Anne Preissel ◽  
Susanne Wagner ◽  
Marcus R Makowski ◽  
Alexandra Keithahn ◽  
...  
2018 ◽  
Vol 39 (18) ◽  
pp. 1656-1656
Author(s):  
Aslihan Erbay ◽  
Youssef S Abdelwahed ◽  
Barbara E Stähli ◽  
Ulf Landmesser ◽  
David M Leistner

2007 ◽  
Vol 188 (1) ◽  
pp. 70-74 ◽  
Author(s):  
Paul M. Bansmann ◽  
Andrew N. Priest ◽  
Kai Muellerleile ◽  
Alexander Stork ◽  
Gunnar K. Lund ◽  
...  

2011 ◽  
Vol 13 (S1) ◽  
Author(s):  
Andrew D Scott ◽  
Jennifer Keegan ◽  
Raad H Mohiaddin ◽  
David N Firmin

2014 ◽  
Vol 59 (12) ◽  
pp. 1779-1786 ◽  
Author(s):  
K. Z. Abd-Elmoniem ◽  
A. B. Unsal ◽  
S. Eshera ◽  
J. R. Matta ◽  
N. Muldoon ◽  
...  

2021 ◽  
Author(s):  
Koji Matsumoto ◽  
Hajime Yokota ◽  
Takafumi Yoda ◽  
Ryota Ebata ◽  
Hiroki Mukai ◽  
...  

Abstract Background: Magnetic resonance vessel wall imaging is desirable for evaluating Kawasaki disease (KD)-associated coronary arterial lesions. Purpose: To evaluate reproducibility of three-dimensional turbo spin-echo (3D-TSE) and two-dimensional dual inversion-recovery turbo spin-echo (2D-DIR-TSE) for coronary vessel wall imaging in KD.Methods: Ten patients were prospectively enrolled. Coronary vessel wall imaging with axial-slice orientation 3D-TSE and 2D-DIR-TSE were acquired for cross-sectional images in aneurysmal and normal regions. Lumen area (LA), wall area (WA), and normalized wall index (NWI) of cross-sectional images were measured in both regions. Reproducibility between 3D-TSE and 2D-DIR-TSE was evaluated via intraclass correlation coefficients (ICCs) and Bland-Altman plots.Results: 48 points (aneurysmal, 27; normal, 21) were evaluated. There were high ICCs between 3D-TSE and 2D-DIR-TSE in LA (0.95) and WA (0.95). In aneurysmal regions, 95% limits of agreement were LA, WA, and NWI of -29.9–30.4 mm2, -18.8–15.0 mm2, and -0.22–0.20, respectively. In normal regions, the 95% limits of agreement were LA, WA, and NWI of -4.44–4.38 mm2, -3.51–4.30 mm2, and -0.14–0.16, respectively. No fixed and proportional biases between 3D-TSE and 2D-DIR-TSE images in aneurysmal and normal regions were noted.Conclusions: 3D-TSE was reproducible with conventional 2D-DIR-TSE for coronary vessel wall assessment on KD.


Author(s):  
Thomas Wurster ◽  
Ulf Landmesser ◽  
Leif-Christopher Engel ◽  
Boris Bigalke ◽  
Marcus Makowski

Sign in / Sign up

Export Citation Format

Share Document