scholarly journals Posterior pole retinotomy for treatment of recurrent macular hole retinal detachment in highly myopic eyes: a pilot study

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Xianggui Wang ◽  
Xuezhi Zhou ◽  
Ying Zhu ◽  
Huizhuo Xu

Abstract Background To investigate the feasibility and efficacy of posterior pole retinotomy to treat recurrent macular hole retinal detachment (MHRD) in highly myopic patients. Methods We performed a retrospective study and reviewed the medical records in our hospital between January 1, 2016 and December 31, 2018. Highly myopic patients who received posterior pole retinotomy with silicone oil tamponade for their recurrent MHRD after pars plana vitrectomy were included in the analysis. Postoperative retinal reattachment, best-corrected visual acuity (BCVA), macular hole closure, and complications were evaluated. Results There were 11 patients (11 eyes) included in this study. All retinas were reattached. Silicone oil was successfully removed from all eyes 1.5–3 months after the surgery. Macular holes were completely closed in three eyes and remained flat open in eight eyes. The BCVA of all eyes improved significantly at 12 months after surgery (logarithm of the minimal angle of resolution, pre vs. postoperatively, 1.87 ± 0.44 vs. 1.15 ± 0.24, P < 0.05). None of the patients had complications such as endophthalmitis, fundus hemorrhage, retinal redetachment, and proliferative vitreoretinopathy. Conclusion Posterior pole retinotomy is a safe and effective surgery to treat recurrent MHRD after pars plana vitrectomy in highly myopic patients.

2018 ◽  
Vol 28 (5) ◽  
pp. 503-514 ◽  
Author(s):  
Janusz Pieczynski ◽  
Patrycja Kuklo ◽  
Andrzej Grzybowski

Purpose: To evaluate usefulness of posterior vitrectomy with silicone oil tamponade for primary and secondary macular hole closure. Methods: We searched for publications on the surgical treatment of full-thickness idiopathic and recurrent macular hole. We divided reports into two groups: primary macular hole repair and recurrent macular hole repair with silicone oil tamponade. Results: In primary macular hole treatment, different authors confirmed effectiveness of silicone oil tamponade. They suggest that the most important factor for successful outcome was completeness of vitreous cavity filling with oil. Complications after this method were comparable to those after gas tamponade. However, even if good anatomical results are achieved in secondary macular hole closure, visual acuity is sometimes less rewarding. Conclusion: There are reports on good efficacy of silicone oil tamponade for primary and recurrent macular hole closure. Anatomical closure and visual acuity rates in pars plana vitrectomy with silicone oil and with gas filling are comparable. Gas tamponade seems to be safer and needs no more surgery. Postoperative complications in both methods are similar, but all patients with silicone oil filling need to undergo a reoperation to have the silicone removed. There are also other surgical techniques for primary macular hole closure as well as for unsuccessful primary macular hole procedures. We think that primary macular hole closure should be performed with gas tamponade, supported with different adjuvants, as a method of choice. Silicone oil tamponade could be still an alternative in cases, when there are no more efficient techniques or possibilities to treat with success recurrent macular hole.


2020 ◽  
Vol 2020 ◽  
pp. 1-4
Author(s):  
A. Altun

Purpose. We aimed at reminding that X-linked retinoschisis may also be seen in female patients and share our vitreoretinal surgical experience. Methods. The patient underwent pars plana vitrectomy including the closure of the macular holes with inverted ILM flap technique bilaterally. Lens extractions were performed by phacoemulsification during the removal of silicone oil endotamponade. Patient. An 18-year-old girl with X-linked retinoschisis and large macular holes in both eyes presented to the clinic of ophthalmology. It was confirmed that the patient had RS1 mutation Results. Nine-month-follow-up was uneventful for retinal findings. Significant improvement in visual acuity was achieved, and macular holes were remained closed. Conclusion. In cases with large macular holes due to XLR, an inverted ILM flap technique might be safe and effective. Four-month-silicone-endotamponade might be sufficient.


2016 ◽  
Vol 7 (6) ◽  
pp. 43-46
Author(s):  
Lalit Agarwal ◽  
Nisha Agrawal ◽  
Pratap Karki ◽  
Abhishek Anand

Background:  A macular hole is a full-thickness defect of retinal tissue involving the anatomic fovea, thereby affecting central visual acuity. Pars plana vitrectomy and gas tamponade is a recognised modality of treatment for macular hole.Larger holes are more likely to remain open after repair and late reopening after an initially closed macular hole is seen in macular holes larger than 400 μm.Aims and Objective: To evaluate the anatomical and functional outcome of pars plana vitrectomy with internal limiting membrane peeling for chronic stage 3 macular hole.Materials and Methods: Records of 15 patients with stage 3 chronic macular holes operated from 1st January 2013 to 30th June 2013 and completed 1 year of follow up were retrospectively evaluated and included in the study. Preoperative best distance corrected visual acuity (BCVA), preoperative macular hole size, final BCVA and macular hole status at 1 year follow up were recorded. Macular hole closure and visual improvement was calculated. Correlation of macular hole closure and visual improvement with various macular hole parameter was estimated.Results: Eleven (73.3%) macular holes closed at 1 year follow-up. Mean BCVA improved from 1.2 ± 0.27 to 0.89 ± 0.36 logarithm of minimum angle of resolution at 1 year (p<0.001). Visual improvement was seen in only eight (53.3%) eyes. Both macular hole closure and visual improvement showed no correlation with minimum linear diameter, base diameter and hole height.Conclusion: Chronic stage 3 macular hole can be closed successfully in majority of patients with fairly good visual improvement. Macular hole parameters of stage 3 holes may not have any correlation with the anatomical and visual outcome.Asian Journal of Medical Sciences Vol.7(6) 2016 43-46


2018 ◽  
Vol 24 (29) ◽  
pp. 3476-3493 ◽  
Author(s):  
Dorota Raczyńska ◽  
Kamila Mitrosz ◽  
Krystyna Raczyńska ◽  
Leopold Glasner

Purpose: Pars plana vitrectomy (PPV) and silicone oil endotamponade have been used as a treatment in rhegmatogenous retinal detachment (RRD). Improvement in the modality of spectral-domain optical coherence tomography (SD-OCT) allows for the assessment of ganglion cell layer-inner plexiform layer (GCL-IPL) in the macular region. Information about the GCL-IPL status may be a response to the question as to why the visual recovery after PPV with silicone oil tamponade is incomplete. The aim of the study was to evaluate the impact of silicone oil on GCL-IPL and compare it with other endotamponade types such as Sulfur hexafluoride gas (SF6), Perfluoropropane gas (C3F8) used during PPV performed due to RRD. Patients and Methods: The study involved 57 eyes after PPV and 57 healthy, control eyes of patients with primary RRD who had undergone successful PPV. The patients were divided into three subgroups depending on the endotamponade type, and were tracked with complete ophthalmological examination during a period of 6 months. PPV with internal tamponade silicone oil, 24% SF6 or 14% C3F8 was performed. The medical records were reviewed and compared between the groups. Results: SD-OCT analysis detected a significant reduction of average GCL-IPL thickness and reduction of GCLIPL parameter in almost all examined sectors in the group with silicone oil endotamponade during all follow-up visits (P<0.05). The study showed a significant vision deterioration in the silicone oil group in comparison with the SF6 group on all follow-up visits (P<0.05). Conclusion: This is the first in vivo SD-OCT study describing the toxic effect of silicone oil endotamponade on GCL-IPL complex after PPV for RRD. The study confirmed that the GCL-IPL complex value can be a predictive factor for assessing the final visual acuity. SD-OCT should be recommended as a clinical standard in the followup treatment of patients after PPV for RRD, especially with the use of silicone oil endotamponade. Plain Language Summary: The aim of the study was to examine the impact of silicone oil on the ganglion cell complex. The ganglion cell is a neuron type located in the retina and takes part in transmitting visual information from the retina to the brain. Silicone oil is a substance used during eye surgery called pars plana vitrectomy. This tamponade type acts to hold the retina in a proper position. However, during the retinal detachment, which is the separation of the retina from the layer underneath, a reduction of neurons is observed. We decided to use a new technology device called SD-OCT to determine the thickness of the ganglion cell complex. We compared the impact of silicone oil with other tamponade types. We found that silicone oil causes a reduction in the ganglion cell complex. Moreover, we observed vision deterioration in eyes treated with a silicone oil tamponade. The research describes the toxic effect of silicone oil on ganglion cells. Ganglion cell values may be used to determine visual improvement or deterioration after eye surgery with silicone oil tamponade. SD-OCT should be a clinical standard in monitoring patients with silicone oil tamponade.


Sign in / Sign up

Export Citation Format

Share Document