scholarly journals Does thread shape affect the fixation strength of the bioabsorbable interference screws for anterior cruciate ligament reconstructions? A biomechanical study

2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Gerardo L. Garcés ◽  
Oscar Martel ◽  
Alejandro Yánez ◽  
Alberto Cuadrado
2021 ◽  
Author(s):  
Yuanjun Teng ◽  
Lijun Da ◽  
Xiaohui Zhang ◽  
Hong Wang ◽  
Hua Han ◽  
...  

Abstract Background: Interference screw is commonly used for graft fixation in anterior cruciate ligament (ACL) reconstruction However, previous studies h a d reported that the insertion of interference screws significantly caused graft laceration . The purpose of this study was to determine whether sutures reduce d the graft laceration from the insertion of interference screws in ACL reconstruction. Methods: Porcine tibias and bovine extensor tendons were used for establishing a knee model of ACL reconstruction in vitro . The ends of grafts were sutured using three different sutures, including the bioabsorbable, Ethibond and ultra high molecular weight polyethylene (UHMWPE) sutures Poly ether ether ketone (PEEK) interference screw s w ere used fortibial fixation Biomechanical tests were performed to investigate the protective effects of different sutures on grafts Results : All prepared tendons and bone specimens showed similar characteristics (length, weight, and pre tension of the tendons, tibial bone mineral density) among all groups ( P 0.05). The biomechanical test s demonstrated that PEEK interference screw s significantly caused the graft laceration P 0.05). However, all sutures (the bioabsorbable, Ethibond and UHMWPE sutures) did not reduce the graft laceration in ACL reconstruction P 0.05). Conclusions : PEEK interference screw s significantly weakened the biomechanical properties of grafts during tibial fixation in ACL reconstruction. Absorbable Ethibond and UHMWPE sutures did not provide protective effects on grafts during ACL reconstruction.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Yuanjun Teng ◽  
Xiaohui Zhang ◽  
Lijun Da ◽  
Jie Hu ◽  
Hong Wang ◽  
...  

Abstract Background Interference screw is commonly used for graft fixation in anterior cruciate ligament (ACL) reconstruction. However, previous studies had reported that the insertion of interference screws significantly caused graft laceration. The purposes of this study were to (1) quantitatively evaluate the graft laceration from one single insertion of PEEK interference screws; and (2) determine whether different types of sutures reduced the graft laceration after one single insertion of interference screws in ACL reconstruction. Methods The in-vitro ACL reconstruction model was created using porcine tibias and bovine extensor digitorum tendons of bovine hind limbs. The ends of grafts were sutured using three different sutures, including the bioabsorbable, Ethibond and ultra-high molecular weight polyethylene (UHMWPE) sutures. Poly-ether-ether-ketone (PEEK) interference screws were used for tibial fixation. This study was divided into five groups (n = 10 in each group): the non-fixed group, the non-sutured group, the absorbable suture group, the Ethibond suture group and the UHMWPE suture group. Biomechanical tests were performed using the mode of pull-to-failure loading tests at 10 mm/min. Tensile stiffness (newtons per millimeter), energy absorbed to failure (in joules) and ultimate load (newtons) were recorded for analysis. Results All prepared tendons and bone specimens showed similar characteristics (length, weight, and pre-tension of the tendons, tibial bone mineral density) among all groups (P > 0.05). The biomechanical tests demonstrated that PEEK interference screws significantly caused the graft laceration (P < 0.05). However, all sutures (the bioabsorbable, Ethibond and UHMWPE sutures) did not reduce the graft laceration in ACL reconstruction (P > 0.05). Conclusions Our biomechanical study suggested that the ultimate failure load of grafts was reduced of approximately 25 % after one single insertion of a PEEK interference screw in ACL reconstruction. Suturing the ends of the grafts using different sutures (absorbable, Ethibond and UHMWPE sutures) did not decrease the graft laceration caused by interference screws.


Sign in / Sign up

Export Citation Format

Share Document