interference screws
Recently Published Documents


TOTAL DOCUMENTS

146
(FIVE YEARS 24)

H-INDEX

32
(FIVE YEARS 3)

2021 ◽  
Vol 6 (10) ◽  
pp. 3231-3243
Author(s):  
Ying Luo ◽  
Chao Zhang ◽  
Jue Wang ◽  
Fangfei Liu ◽  
Kelvin Wingho Chau ◽  
...  

2021 ◽  
Vol 9 (8) ◽  
pp. 232596712110215
Author(s):  
Baoyun Xu ◽  
Yuling Yin ◽  
Yanling Zhu ◽  
Yu Yin ◽  
Weili Fu

Background: Bioabsorbable interference screws and metallic interference screws are both widely used for graft fixation, but it remains unclear which screw type is superior. Purpose: To compare clinical outcomes and complications between bioabsorbable and metallic interference screws for anterior cruciate ligament reconstruction (ACLR). Study Design: Systematic review; Level of evidence, 1. Methods: The literature was searched for relevant randomized controlled trials published between 1966 and 2020. Two investigators independently assessed risk of bias in the included studies, and data were pooled to calculate mean differences (MDs) for continuous outcomes and risk ratios (RRs) for dichotomous outcomes, together with 95% CIs. Meta-analysis was performed using a random- or fixed-effects model, depending on the heterogeneity in the data. Results: Included were 14 randomized controlled trials involving 1032 patients who underwent ACLR: 528 patients with bioabsorbable screws and 504 patients with metallic screws. The 2 groups did not differ significantly in International Knee Documentation Committee score (RR, 1.04; 95% CI, 0.97 to 1.11), Lysholm score (MD, 0.59; 95% CI, –0.46 to 1.63), range of motion deficit (RR, 0.95; 95% CI, 0.67 to 1.34), positive pivot-shift test (RR, 0.87; 95% CI, 0.61 to 1.24), positive Lachman test (RR, 0.82; 95% CI, 0.48 to 1.39), or KT-1000 arthrometer value (MD, 0.01; 95% CI, –0.16 to 0.18). However, bioabsorbable screws were associated with a significantly higher risk of complications (RR, 1.70; 95% CI, 1.16 to 2.50), such as graft rupture, joint effusion, and infection. Conclusion: The results of this review showed that there was no difference between metallic and bioabsorbable screws for ACLR in terms of subjective knee function or knee laxity, but metallic interference screws had fewer complications.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Yuanjun Teng ◽  
Xiaohui Zhang ◽  
Lijun Da ◽  
Jie Hu ◽  
Hong Wang ◽  
...  

Abstract Background Interference screw is commonly used for graft fixation in anterior cruciate ligament (ACL) reconstruction. However, previous studies had reported that the insertion of interference screws significantly caused graft laceration. The purposes of this study were to (1) quantitatively evaluate the graft laceration from one single insertion of PEEK interference screws; and (2) determine whether different types of sutures reduced the graft laceration after one single insertion of interference screws in ACL reconstruction. Methods The in-vitro ACL reconstruction model was created using porcine tibias and bovine extensor digitorum tendons of bovine hind limbs. The ends of grafts were sutured using three different sutures, including the bioabsorbable, Ethibond and ultra-high molecular weight polyethylene (UHMWPE) sutures. Poly-ether-ether-ketone (PEEK) interference screws were used for tibial fixation. This study was divided into five groups (n = 10 in each group): the non-fixed group, the non-sutured group, the absorbable suture group, the Ethibond suture group and the UHMWPE suture group. Biomechanical tests were performed using the mode of pull-to-failure loading tests at 10 mm/min. Tensile stiffness (newtons per millimeter), energy absorbed to failure (in joules) and ultimate load (newtons) were recorded for analysis. Results All prepared tendons and bone specimens showed similar characteristics (length, weight, and pre-tension of the tendons, tibial bone mineral density) among all groups (P > 0.05). The biomechanical tests demonstrated that PEEK interference screws significantly caused the graft laceration (P < 0.05). However, all sutures (the bioabsorbable, Ethibond and UHMWPE sutures) did not reduce the graft laceration in ACL reconstruction (P > 0.05). Conclusions Our biomechanical study suggested that the ultimate failure load of grafts was reduced of approximately 25 % after one single insertion of a PEEK interference screw in ACL reconstruction. Suturing the ends of the grafts using different sutures (absorbable, Ethibond and UHMWPE sutures) did not decrease the graft laceration caused by interference screws.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Nazanin Daneshvarhashjin ◽  
Mahmoud Chizari ◽  
Javad Mortazavi ◽  
Gholamreza Rouhi

Abstract Background Superior biomechanical performance of tapered interference screws, compared with non-tapered screws, with reference to the anterior cruciate ligament (ACL) reconstruction process, has been reported in the literature. However, the effect of tapered interference screw’s body slope on the initial stability of ACL is poorly understood. Thus, the main goal of this study was to investigate the effect of the interference screw’s body slope on the initial stability of the reconstructed ACL. Methods Based on the best screw-bone tunnel diameter ratios in non-tapered screws, two different tapered interference screws were designed and fabricated. The diameters of both screws were equal to bone tunnel diameter in one-third of their length from screw tip, then they were gradually increased by 1mm, in the lower slope (LSTIS), and 2 mm, in the higher slope (HSTIS) screws. To simulate the ACL reconstruction, sixteen soft tissue grafts were fixed, using HSTIS and LSTIS, in synthetic bone blocks. Through applying sub-failure cyclic incremental tensile load, graft-bone-screw construct’s stiffness and graft laxity in each cycle, also through applying subsequent step of loading graft to the failure, maximum load to failure, and graft’s mode of failure were determined. Accordingly, the performance of the fabricated interference screws was compared with each other. Results HSTIS provides a greater graft-bone-screw construct stiffness, and a lower graft laxity, compared to LSTIS. Moreover, transverse rupture of graft fibers for LSTIS, and necking of graft in the HSTIS group were the major types of grafts’ failure. Conclusions HSTIS better replicates the intact ACL’s behavior, compared to LSTIS, by causing less damage in graft’s fibers; reducing graft laxity; and increasing fixation stability. Nonetheless, finding the optimal slope remains as an unknown and can be the subject of future studies.


2021 ◽  
Vol 8 (18) ◽  
pp. 1258-1263
Author(s):  
Vishal Singh ◽  
Alokeshwar Sharma ◽  
Avinash Gundavarapu ◽  
Tejas Patel ◽  
Santosh Kumar M

BACKGROUND Traditionally, metallic interference screws were considered to have increased resistance to load than bio absorbable screws in anterior cruciate ligament (ACL) reconstruction. We did a comparative evaluation of biodegradable and metallic interference screws for tibial sided ACL reconstruction and also analysed complications, compared clinical outcome, did imaging study of ACL single bundle reconstruction by using titanium & newer poly–L-lactic acid (PLLA) bio absorbable screws to determine as to whether bio absorbable screw which costs double the metallic screw, is functionally better than standard metallic screws. METHODS This is a prospective comparative study conducted among 50 patients aged between 15 and 55 years with clinical and MRI confirmation of complete ACL tear, treated arthroscopically with ACL reconstruction with either bio absorbable (group 1) or metallic (group 2) interference screw and both the groups were compared on follow up for an average duration of 12 months. Lysholm and Gillquist Knee Scoring Scale were used and outcome scores were divided into excellent, good, fair and poor. RESULTS In our study 41 patients were males and 9 were females. Bio screw was used in 24 males and 6 female patients. Metallic screw was used in 17 males and 3 females. Outcome score was excellent in 26 (52 %) cases, good in 18 (36 %) cases, fair in 4 (8 %) cases, poor in 2 (4 %) cases. The mean Lysholm score in bio absorbable group was 93.13 and in metallic group was 89.70. Knee effusion was higher in bio screw group and infection rate was higher in metallic group. CONCLUSIONS In our study, the difference between bio absorbable screw group and metallic screw group was insignificant with regard to final patient outcome. Final osseointegration was better with bio absorbable screw, but increased cost of implant and almost same results compared to metallic screw does not make the bio absorbable screw superior to its counterpart. KEYWORDS ACL, Bio Absorbable Interference Screws, Metallic Interference Screws


2021 ◽  
Vol 9 (5) ◽  
pp. 232596712110064
Author(s):  
Brian Scrivens ◽  
Melissa A. Kluczynski ◽  
Marc S. Fineberg ◽  
Leslie J. Bisson

Background: Bioabsorbable interference screws tend to have high resorption rates after anterior cruciate ligament (ACL) reconstruction; however, no studies have examined screws composed of 30% biphasic calcium phosphate and 70% poly-d-lactide (30% BCP/70% PLDLA). Purpose: To evaluate femoral and tibial tunnel widening and resorption of 30% BCP/70% PLDLA interference screws and replacement with bone at 2 to 5 years after ACL reconstruction using bone–patellar tendon–bone (BTB) autograft. Study Design: Case series; Level of evidence, 4. Methods: Included were 20 patients who had undergone ACL reconstruction using BTB autograft and were reevaluated 2 to 5 years after surgery using computed tomography scans. Tunnel measurements were obtained from computed tomography scans in the sagittal and coronal planes and were compared with known tunnel measurements based on operative reports. These images and measurements were used to assess tunnel widening, resorption of the 30% BCP/70% PLDLA screw, its replacement with bone, and possible cyst formation. Paired t tests were used to compare initial and final femoral and tibial tunnel measurements. Results: The cross-sectional area of the femoral tunnel decreased at the aperture ( P = .03), middle ( P = .0002), and exit ( P < .0001) of the tunnel compared with the initial femoral tunnel size, and the tibial tunnel cross-sectional area decreased at the aperture ( P < .0001) and exit ( P = .01) of the tunnel compared with the initial tibial tunnel size. Bone formation was observed in 100% of femoral tunnels and 94.7% of tibial tunnels. Screw resorption was 100% in the femur and 94.7% in the tibia at the final follow-up. Cysts were noted around the femoral tunnel in 2 patients (5.1%). Conclusion: The 30% BCP/70% PLDLA interference screws used for ACL reconstruction using BTB autograft had high rates of resorption and replacement with bone, and there were no increases in tunnel size at 2 to 5 years postoperatively. The authors observed a low rate of cyst formation and no other adverse events stemming from the use of this specific biointerference screw, suggesting that this type of screw is a reasonable option for graft fixation with minimal unfavorable events and a reliable resorption profile.


2021 ◽  
Author(s):  
Yuanjun Teng ◽  
Lijun Da ◽  
Xiaohui Zhang ◽  
Hong Wang ◽  
Hua Han ◽  
...  

Abstract Background: Interference screw is commonly used for graft fixation in anterior cruciate ligament (ACL) reconstruction However, previous studies h a d reported that the insertion of interference screws significantly caused graft laceration . The purpose of this study was to determine whether sutures reduce d the graft laceration from the insertion of interference screws in ACL reconstruction. Methods: Porcine tibias and bovine extensor tendons were used for establishing a knee model of ACL reconstruction in vitro . The ends of grafts were sutured using three different sutures, including the bioabsorbable, Ethibond and ultra high molecular weight polyethylene (UHMWPE) sutures Poly ether ether ketone (PEEK) interference screw s w ere used fortibial fixation Biomechanical tests were performed to investigate the protective effects of different sutures on grafts Results : All prepared tendons and bone specimens showed similar characteristics (length, weight, and pre tension of the tendons, tibial bone mineral density) among all groups ( P 0.05). The biomechanical test s demonstrated that PEEK interference screw s significantly caused the graft laceration P 0.05). However, all sutures (the bioabsorbable, Ethibond and UHMWPE sutures) did not reduce the graft laceration in ACL reconstruction P 0.05). Conclusions : PEEK interference screw s significantly weakened the biomechanical properties of grafts during tibial fixation in ACL reconstruction. Absorbable Ethibond and UHMWPE sutures did not provide protective effects on grafts during ACL reconstruction.


2021 ◽  
Author(s):  
Nazanin Daneshvarhashjin ◽  
Mahmoud Chizari ◽  
SM Javad Mortazavi ◽  
Gholamreza Rouhi

Abstract Background Superior biomechanical performance of tapered interference screws, in regard to reconstruction of anterior cruciate ligament (ACL), compared with non-tapered screws, has been reported in the literature. However, the effect of tapered interference screw’s body slope on the initial stability of ACL is not studied yet. Thus, the main goal of this study was to investigate the effects of interference screw's body slope on the initial stability of the reconstructed ACL. Methods Based on the best screw-bone tunnel diameter ratios in non-tapered screws, two different tapered interference screw were designed and fabricated. The diameters of both screws were considered to be equal to bone tunnel diameter in one third of their length from screw tip, then they were gradually increased by 1mm, in the lower slope (LSTIS), and 2 mm, in the higher slope (HSTIS) screws. To simulate the ACL reconstruction, sixteen soft tissue grafts were fixed, using HSTIS and LSTIS, in synthetic bone blocks. Through applying sub-failure cyclic incremental tensile load, graft-bone-screw construct's stiffness and graft laxity in each cycle, and through applying subsequent step of loading graft to the failure, maximum load to failure, and graft’s mode of failure were determined. Accordingly, performance of the fabricated interference screws were compared with each other. Results HSTIS, compared to LSTIS, provides a greater graft-bone-screw construct stiffness, and a lower graft laxity. Moreover, transverse rupture of graft fibers for LSTIS, and necking of graft in HSTIS group were the major types of grafts' failure. ConclusionHSTIS compared to LSTIS, by causing less damage in graft's fibers; reducing graft laxity; and increasing fixation stability, better replicates the intact ACL's behavior.


2020 ◽  
Vol 7 (1) ◽  
Author(s):  
Martin Lind ◽  
Torsten Nielsen ◽  
Ole Gade Sørensen ◽  
Bjarne Mygind-Klavsen ◽  
Peter Faunø ◽  
...  

Abstract Purpose Open or fenestrated interference screw design that allow bone ingrowth is a concept for improved bone healing to softtissue graft and bone filling in bone tunnels after anterior cruciate ligament reconstruction (ACLR) The aim of the current study was to assess CT scanning evaluated bone ingrowth into an open architecture interference screws in the tibial tunnel of patients undergoing ACL with soft tissue grafts. It was hypothesized that open architecture interference screws would stimulate bone ingrowth into the screw cavities. Methods Twelve patients requiring ACLR were included. They underwent arthroscopic ACLR with semitendinosus−/gracilis tendon graft and an open architecture polyetheretherketone (PEEK) interference screw. The patients were scanned with a multi-slice CT scanner two weeks, six and twelve months postoperatively. On CT reconstruction slices bone ingrowth into the screw was measured. Subjective and objective clinical outcome international knee documentation committee score and instrumented knee laxity determination were collected. Results At six months no implants demonstrated more than 10% bone ingrowth. At twelve months 42% (5/12) implants had more than 10% bone ingrowth (p = 0.009). The average bone filling into the screws was 7.7%. There was no tunnel widening or cyst formation seen in relation to any of the implants. Subjective IKDC score improved significantly from 50.6 baseline to 80.1 at 24 month follow-up. Preoperative side-to-side knee laxity improved from 3.7 (2.1) to 1.4 (1.2) mm at twelve months. There were no serious adverse events in relation to the new open architecture thread PEEK interference screw during or after hamstring ACL reconstruction. Conclusion The present study demonstrated that open architecture thread PEEK interference screw can stimulate bone ingrowth into the screws after soft tissue ACL reconstruction with at 12 months with an average bone filling into screws was 7.7%. Knee stability, functional, subjective and objective outcomes were similar to large volume ACL outcome studies. Trial registration The study was registered at ClinicalTrials # NCT02382341. 12-09-2014. Level of evidence IV.


Sign in / Sign up

Export Citation Format

Share Document