Feasibility and safety of low-flow extracorporeal CO2 removal managed with a renal replacement platform to enhance lung-protective ventilation of patients with mild-to-moderate ARDS
Critical Care
◽
10.1186/s13054-018-2038-5
◽
2018
◽
Vol 22
(1)
◽
Cited By ~ 39
Author(s):
Matthieu Schmidt
◽
Samir Jaber
◽
Elie Zogheib
◽
Thomas Godet
◽
Gilles Capellier
◽
...
Keyword(s):
Protective Ventilation
◽
Low Flow
◽
Lung Protective Ventilation
◽
Co2 Removal
◽
Extracorporeal Co2 Removal
Download Full-text
Related Documents
Cited By
References
Low-Flow Venovenous CO2 Removal in Association With Lung Protective Ventilation Strategy in Patients Who Develop Severe Progressive Respiratory Acidosis After Lung Transplantation
Transplantation Proceedings
◽
10.1016/j.transproceed.2013.07.022
◽
2013
◽
Vol 45
(7)
◽
pp. 2741-2745
◽
Cited By ~ 2
Author(s):
F. Ruberto
◽
B. Bergantino
◽
M.C. Testa
◽
C. D'Arena
◽
V. Zullino
◽
...
Keyword(s):
Lung Transplantation
◽
Respiratory Acidosis
◽
Protective Ventilation
◽
Low Flow
◽
Lung Protective Ventilation
◽
Co2 Removal
◽
Ventilation Strategy
◽
Protective Ventilation Strategy
◽
Lung Protective Ventilation Strategy
Download Full-text
Low flow extracorporeal CO2 removal in ARDS patients: a prospective short-term crossover pilot study
BMC Anesthesiology
◽
10.1186/s12871-017-0445-9
◽
2017
◽
Vol 17
(1)
◽
Cited By ~ 11
Author(s):
Harlinde Peperstraete
◽
Sunny Eloot
◽
Pieter Depuydt
◽
Filip De Somer
◽
Carl Roosens
◽
...
Keyword(s):
Pilot Study
◽
Low Flow
◽
Co2 Removal
◽
Short Term
◽
Extracorporeal Co2 Removal
Download Full-text
Low-Flow Veno-Venous Extracorporeal CO2 Removal: First Clinical Experience in Lung Transplant Recipients
The International Journal of Artificial Organs
◽
10.5301/ijao.5000375
◽
2014
◽
Vol 37
(12)
◽
pp. 911-917
◽
Cited By ~ 6
Author(s):
Franco Ruberto
◽
Bartolomeo Bergantino
◽
Maria Cristina Testa
◽
Carmen D'Arena
◽
Mattia Bernardinetti
◽
...
Keyword(s):
Clinical Experience
◽
Lung Transplant
◽
Low Flow
◽
Co2 Removal
◽
Transplant Recipients
◽
Extracorporeal Co2 Removal
◽
Lung Transplant Recipients
Download Full-text
Feasibility and safety of extracorporeal CO2 removal to enhance protective ventilation in acute respiratory distress syndrome: the SUPERNOVA study
Intensive Care Medicine
◽
10.1007/s00134-019-05567-4
◽
2019
◽
Vol 45
(5)
◽
pp. 592-600
◽
Cited By ~ 54
Author(s):
Alain Combes
◽
◽
Vito Fanelli
◽
Tai Pham
◽
V. Marco Ranieri
Keyword(s):
Acute Respiratory Distress Syndrome
◽
Respiratory Distress Syndrome
◽
Respiratory Distress
◽
Distress Syndrome
◽
Protective Ventilation
◽
Co2 Removal
◽
Extracorporeal Co2 Removal
Download Full-text
A case of acute respiratory distress syndrome induced by pneumonia and empyema that was managed using low-flow extracorporeal CO2 removal
Journal of the Japanese Society of Intensive Care Medicine
◽
10.3918/jsicm.21.516
◽
2014
◽
Vol 21
(5)
◽
pp. 516-520
Author(s):
Tomohiro Kondo
◽
Yu Wakabayashi
◽
Masaaki Sakuraya
◽
Kenichi Yoshida
Keyword(s):
Acute Respiratory Distress Syndrome
◽
Respiratory Distress Syndrome
◽
Respiratory Distress
◽
Distress Syndrome
◽
Low Flow
◽
Co2 Removal
◽
Extracorporeal Co2 Removal
Download Full-text
Bicarbonate Dialysis (Using a Bicarbonate of 16 mmol) Results in CO2 Removal at Rates Comparable With Existing Low-Flow Extracorporeal CO2 Removal—Is the Use of Diffusion and Convection Association to Increase CO2 Removal a Fact or a Fiction?
Critical Care Medicine
◽
10.1097/ccm.0000000000004839
◽
2021
◽
Vol 49
(4)
◽
pp. e475-e476
◽
Cited By ~ 1
Author(s):
Patrick M. Honore
◽
Sebastien Redant
◽
Luc Kugener
◽
Leonel Barreto Gutierrez
◽
Rachid Attou
◽
...
Keyword(s):
Low Flow
◽
Co2 Removal
◽
Extracorporeal Co2 Removal
◽
Diffusion And Convection
Download Full-text
Centrifugal pump performance during low-flow extracorporeal CO2 removal; safety considerations
Perfusion
◽
10.1177/0267659114540024
◽
2014
◽
Vol 30
(1)
◽
pp. 17-23
◽
Cited By ~ 2
Author(s):
AP Simons
◽
EGHJ Martens
◽
YM Ganushchak
◽
PW Weerwind
Keyword(s):
Centrifugal Pump
◽
Low Flow
◽
Co2 Removal
◽
Extracorporeal Co2 Removal
◽
Pump Performance
◽
Safety Considerations
Download Full-text
Lower tidal volume strategy (≈3 ml/kg) combined with extracorporeal CO2 removal versus ‘conventional’ protective ventilation (6 ml/kg) in severe ARDS
Intensive Care Medicine
◽
10.1007/s00134-012-2787-6
◽
2013
◽
Vol 39
(5)
◽
pp. 847-856
◽
Cited By ~ 306
Author(s):
Thomas Bein
◽
Steffen Weber-Carstens
◽
Anton Goldmann
◽
Thomas Müller
◽
Thomas Staudinger
◽
...
Keyword(s):
Tidal Volume
◽
Protective Ventilation
◽
Co2 Removal
◽
Extracorporeal Co2 Removal
◽
Lower Tidal Volume
◽
Volume Strategy
Download Full-text
Faculty Opinions recommendation of Lower tidal volume strategy (≈3 ml/kg) combined with extracorporeal CO2 removal versus 'conventional' protective ventilation (6 ml/kg) in severe ARDS: the prospective randomized Xtravent-study.
Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature
◽
10.3410/f.717976275.793501701
◽
2014
◽
Author(s):
Ary Serpa Neto
Keyword(s):
Tidal Volume
◽
Protective Ventilation
◽
Co2 Removal
◽
Extracorporeal Co2 Removal
◽
Lower Tidal Volume
◽
Volume Strategy
Download Full-text
Commentary on: Centrifugal pump performance during low-flow extracorporeal CO2 removal; safety considerations
Perfusion
◽
10.1177/0267659114545029
◽
2014
◽
Vol 30
(1)
◽
pp. 24-24
Author(s):
Antoine Simons
Keyword(s):
Centrifugal Pump
◽
Low Flow
◽
Co2 Removal
◽
Extracorporeal Co2 Removal
◽
Pump Performance
◽
Safety Considerations
Download Full-text
Sign in / Sign up
Close
Export Citation Format
Close
Share Document
Close