scholarly journals Optical tissue measurements of invasive carcinoma and ductal carcinoma in situ for surgical guidance

2021 ◽  
Vol 23 (1) ◽  
Author(s):  
Lisanne L. de Boer ◽  
Esther Kho ◽  
Koen K. Van de Vijver ◽  
Marie-Jeanne T. F. D. Vranken Peeters ◽  
Frederieke van Duijnhoven ◽  
...  

Abstract Background Although the incidence of positive resection margins in breast-conserving surgery has decreased, both incomplete resection and unnecessary large resections still occur. This is especially the case in the surgical treatment of ductal carcinoma in situ (DCIS). Diffuse reflectance spectroscopy (DRS), an optical technology based on light tissue interactions, can potentially characterize tissue during surgery thereby guiding the surgeon intraoperatively. DRS has shown to be able to discriminate pure healthy breast tissue from pure invasive carcinoma (IC) but limited research has been done on (1) the actual optical characteristics of DCIS and (2) the ability of DRS to characterize measurements that are a mixture of tissue types. Methods In this study, DRS spectra were acquired from 107 breast specimens from 107 patients with proven IC and/or DCIS (1488 measurement locations). With a generalized estimating equation model, the differences between the DRS spectra of locations with DCIS and IC and only healthy tissue were compared to see if there were significant differences between these spectra. Subsequently, different classification models were developed to be able to predict if the DRS spectrum of a measurement location represented a measurement location with “healthy” or “malignant” tissue. In the development and testing of the models, different definitions for “healthy” and “malignant” were used. This allowed varying the level of homogeneity in the train and test data. Results It was found that the optical characteristics of IC and DCIS were similar. Regarding the classification of tissue with a mixture of tissue types, it was found that using mixed measurement locations in the development of the classification models did not tremendously improve the accuracy of the classification of other measurement locations with a mixture of tissue types. The evaluated classification models were able to classify measurement locations with > 5% malignant cells with a Matthews correlation coefficient of 0.41 or 0.40. Some models showed better sensitivity whereas others had better specificity. Conclusion The results suggest that DRS has the potential to detect malignant tissue, including DCIS, in healthy breast tissue and could thus be helpful for surgical guidance.

2015 ◽  
Vol 139 (9) ◽  
pp. 1137-1142 ◽  
Author(s):  
Cathleen Matrai ◽  
Timothy M. D'Alfonso ◽  
Lindsay Pharmer ◽  
Michele B. Drotman ◽  
Rache M. Simmons ◽  
...  

Context Radial scars are benign sclerosing lesions that are routinely excised when diagnosed in a needle core biopsy. Optimal management for patients with incidental and small (≤5 mm) radial scars is uncertain. Objective To assess pathologic upgrade of radial scars diagnosed in needle core biopsy samples and identify a subset of patients who could benefit from conservative management. Design Patients with a diagnosis of radial scar in a needle core biopsy who underwent excision of the biopsied area were identified. Radial scars greater than 5 mm in size and those with coexisting atypia, carcinoma, and papillary lesions were excluded. After histologic-radiographic correlation, rates of pathologic upgrade were assessed. Results Seventy-seven radial scars diagnosed in 66 patients were included. Overall, 9 of 77 (12%) showed upgrade to a high-risk lesion (6 lobular carcinoma in situ, 2 atypical ductal hyperplasia, 1 atypical lobular hyperplasia), while none (0%) showed upgrade to invasive carcinoma or ductal carcinoma in situ. One of 22 incidental radial scars (4.5%) showed upgrade on excision versus 6 of 36 (16.7%) for radial scars considered to be the radiographic target (P = .23). Older age was associated with upgrade (P < .001). Conclusions No incidental or small (≤5 mm) radial scars excised revealed invasive carcinoma or ductal carcinoma in situ on excision. Provided there is good pathologic-radiologic concordance, it appears reasonable for these patients to be managed conservatively.


2004 ◽  
Vol 128 (9) ◽  
pp. 996-999
Author(s):  
Andrew A. Renshaw

Abstract Context.—Although minimally invasive (microinvasive) carcinoma (≤0.1 cm) of the breast is a well-known and well-characterized entity in excision specimens, the significance of small foci of invasion in breast core needle biopsies has not been well described. Objective.—To define the significance of minimally invasive carcinoma in breast core needle biopsies. Design.—Review of a large series of core needle biopsies for invasive carcinomas measuring 0.1 cm or less and correlation of the results with those of subsequent excision. Setting.—Large community hospital. Results.—From approximately 8500 biopsies, a total of 18 cases of minimally invasive carcinoma from 16 women aged 42 to 80 years were identified. All were present on only 1 of 8 slides made from the block. Overall, the incidence was approximately 0.1% of all biopsies and 1% of all invasive carcinomas. Six cases were invasive lobular carcinomas, 1 was tubulolobular carcinoma, 3 were tubular carcinomas, and the remaining 8 were ductal carcinomas. Eight cases were associated with high-grade comedo ductal carcinomas, 2 with low-grade ductal carcinoma in situ, 3 with atypical ductal hyperplasia, 3 with atypical ductal hyperplasia and lobular carcinoma in situ, and 2 with no other lesion. From a total of 8 sections done entirely through the block, the lesion was present on the first level in 4 cases and the fifth level in 5 cases. No cases were identified in the last 3 levels. Subsequent pathology was available for 16 of the 18 cases. Invasive carcinomas measuring more than 1 cm were present in 9 cases (64%; along with 2 positive lymph nodes), invasive carcinomas less than 1 cm in 2 cases (14%), ductal carcinoma alone in 4 cases (29%), and no carcinoma in 1 case (7%). No pathologic or radiologic features were associated with the finding of invasive carcinoma at excision. Conclusion.—Invasive carcinoma measuring 0.1 cm or less is a rare finding in breast core needle biopsies, is commonly associated with in situ carcinomas and atypical hyperplasias, and is often associated with larger invasive foci at excision. However, invasive carcinomas smaller than 0.1 cm can occur without any other significant findings and may require relatively extensive sampling to identify.


2020 ◽  
Vol 27 (11) ◽  
pp. 4459-4465 ◽  
Author(s):  
Tawakalitu O. Oseni ◽  
Barbara L. Smith ◽  
Constance D. Lehman ◽  
Charmi A. Vijapura ◽  
Niveditha Pinnamaneni ◽  
...  

1993 ◽  
Author(s):  
Jon Parker ◽  
David R. Dance ◽  
David H. Davies ◽  
L. J. Yeoman ◽  
M. J. Michell ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document