scholarly journals Outcome of ductus arteriosus stenting including vertical tubular and convoluted tortuous ducts with emphasis on technical considerations

2021 ◽  
Vol 73 (1) ◽  
Author(s):  
Saud Bahaidarah ◽  
Jameel Al-Ata ◽  
Naif Alkhushi ◽  
Ahmad Azhar ◽  
Zaher Zaher ◽  
...  

Abstract Background Ductal stenting is the preferred method of securing adequate pulmonary blood flow in patients with duct-dependent pulmonary circulation. The main limitation in most centers is the difficult vertical tubular or convoluted ducts that represent real challenges to interventional pediatric cardiologists. We present our experience in patent ductus arteriosus (PDA) stenting with some technical tips to overcome difficulties, especially in stenting tortuous or long tubular ducts. This study was conducted on all patients with cyanotic congenital heart disease who underwent PDA stenting between January 2011 and December 2018. Results We attempted to stent the PDA in 43 patients, with a success rate of 93% (40 patients) and only one procedural mortality. There was also one stent migration that needed to be treated with urgent surgery. Three-fourths of the patients had difficult ductal morphology and origin. One stent was used to cover the PDA in 27 patients (62.8%), two stents were used in 13 (30.2%), and three stents were used in 2 patients (4.6%). In-stent stenosis rate was 12.5% (5 patients) and the development of progressive left pulmonary artery stenosis was seen in two patients (5%). Pulmonary artery growth was adequate in all patients. Conclusions PDA stenting is an effective method of palliation for patients with duct-dependent pulmonary circulation. It has low morbidity and mortality rates. Stenting difficult ducts have become more feasible with evolving materials and techniques.

2016 ◽  
Vol 19 (4) ◽  
pp. 187 ◽  
Author(s):  
Dohun Kim ◽  
Si-Wook Kim ◽  
Hong-Ju Shin ◽  
Jong-Myeon Hong ◽  
Ji Hyuk Lee ◽  
...  

A 10-day-old boy was transferred to our hospital due to tachypnea. Patent ductus arteriosus (PDA), 4.8 mm in diameter, with small ASD was diagnosed on echocardiography. Surgical ligation of the ductus was performed after failure of three cycles of ibuprofen. However, the ductus remained open on routine postoperative echocardiography on the second postoperative day, and chest CT revealed inadvertent ligation of the left pulmonary artery (LPA) rather than the PDA. Emergent operation successfully reopened the clipped LPA and ligated the ductus on the same (second postoperative) day.<br />Mechanical ventilator support was weaned on postoperative day 21, and the baby was discharged on postoperative day 47 with a normal left lung shadow.


2020 ◽  
Vol 30 (12) ◽  
pp. 1943-1945
Author(s):  
Semih Murat Yucel ◽  
Irfan Oguz Sahin

AbstractDuctus arteriosus is an essential component of fetal circulation. Due to occurring changes in the cardiopulmonary system physiology after birth, ductus arteriosus closes. Patent ductus arteriosus can be closed by medical or invasive (percutaneous or surgical) treatment methods. Percutaneous or surgical closure of patent ductus arteriosus can be performed for the cases that medical closure failed. Surgical treatment is often preferred method for closure of patent ductus arteriosus in the neonatal period. The most common surgical complications are pneumothorax, recurrent laryngeal nerve injury, bleeding, and recanalisation. A very rare surgical complication is left pulmonary artery ligation that has been presented in a few cases in the literature. Echocardiography control should be performed in the early post-operative period, especially in patients with clinical suspicion. If reoperation is required, it should never be delayed. We report a newborn patient whose left pulmonary artery ligated accidentally during patent ductus arteriosus closure surgery and surgical correction of this complication at the early post-operative period.


2021 ◽  
Vol 15 (1) ◽  
Author(s):  
Hyun-Hwa Cha ◽  
Hae Min Kim ◽  
Won Joon Seong

Abstract Background Unilateral pulmonary artery discontinuity is a rare malformation that is associated with other intracardiac abnormalities. Cases accompanied by other cardiac abnormalities are often missed on prenatal echocardiography. The prenatal diagnosis of isolated unilateral pulmonary artery discontinuity can also be delayed. However, undiagnosed this malformation would have an effect on further prognosis. We report our case of a prenatal diagnosis of pulmonary atresia with ventricular septal defect and left pulmonary artery discontinuity. Case presentation A 33-year-old Asian woman visited our institution at 24 weeks of gestation because of suspected fetal congenital heart disease. Fetal echocardiography revealed a small atretic main pulmonary artery giving rise to the right pulmonary artery without bifurcation and the left pulmonary artery arising from the ductus arteriosus originating from the left subclavian artery. The neonate was delivered by cesarean section at 376/7 weeks of gestation. Postnatal echocardiography and multidetector computed tomography showed a right aortic arch, with the small right pulmonary artery originating from the atretic main pulmonary artery and the left pulmonary artery originating from the left subclavian artery. Patency of the ductus arteriosus from the left subclavian artery was maintained with prostaglandin E1. Right ventricular outflow tract reconstruction and pulmonary angioplasty with Gore-Tex graft patch was performed 25th day after birth. Unfortunately, the neonate died because of right heart failure 8 days postoperation. Conclusion There is a possibility that both pulmonary arteries do not arise from the same great artery (main pulmonary artery or common arterial trunk). Therefore, clinicians should check the origin of both pulmonary arteries.