Model-Based Flexible PCBA Rework Cell Design

2019 ◽  
pp. 6-1-6-44
Author(s):  
Necdet Geren
Keyword(s):  
2020 ◽  
Vol 43 ◽  
Author(s):  
Peter Dayan

Abstract Bayesian decision theory provides a simple formal elucidation of some of the ways that representation and representational abstraction are involved with, and exploit, both prediction and its rather distant cousin, predictive coding. Both model-free and model-based methods are involved.


Author(s):  
J. R. Sellar ◽  
J. M. Cowley

Current interest in high voltage electron microscopy, especially in the scanning mode, has prompted the development of a method for determining the contrast and resolution of images of specimens in controlled-atmosphere stages or open to the air, hydrated biological specimens being a good example. Such a method would be of use in the prediction of microscope performance and in the subsequent optimization of environmental cell design for given circumstances of accelerating voltage, cell gas pressure and constitution, and desired resolution.Fig. 1 depicts the alfresco cell of a focussed scanning transmission microscope with a layer of gas L (and possibly a thin window W) between the objective O and specimen T. Using the principle of reciprocity, it may be considered optically equivalent to a conventional transmission electron microscope, if the beams were reversed. The layer of gas or solid material after the specimen in the STEM or before the specimen in TEM has no great effect on resolution or contrast and so is ignored here.


2001 ◽  
Vol 7 (S2) ◽  
pp. 578-579
Author(s):  
David W. Knowles ◽  
Sophie A. Lelièvre ◽  
Carlos Ortiz de Solόrzano ◽  
Stephen J. Lockett ◽  
Mina J. Bissell ◽  
...  

The extracellular matrix (ECM) plays a critical role in directing cell behaviour and morphogenesis by regulating gene expression and nuclear organization. Using non-malignant (S1) human mammary epithelial cells (HMECs), it was previously shown that ECM-induced morphogenesis is accompanied by the redistribution of nuclear mitotic apparatus (NuMA) protein from a diffuse pattern in proliferating cells, to a multi-focal pattern as HMECs growth arrested and completed morphogenesis . A process taking 10 to 14 days.To further investigate the link between NuMA distribution and the growth stage of HMECs, we have investigated the distribution of NuMA in non-malignant S1 cells and their malignant, T4, counter-part using a novel model-based image analysis technique. This technique, based on a multi-scale Gaussian blur analysis (Figure 1), quantifies the size of punctate features in an image. Cells were cultured in the presence and absence of a reconstituted basement membrane (rBM) and imaged in 3D using confocal microscopy, for fluorescently labeled monoclonal antibodies to NuMA (fαNuMA) and fluorescently labeled total DNA.


Author(s):  
Charles Bouveyron ◽  
Gilles Celeux ◽  
T. Brendan Murphy ◽  
Adrian E. Raftery

Author(s):  
Jonathan Jacky ◽  
Margus Veanes ◽  
Colin Campbell ◽  
Wolfram Schulte
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document